6 (40)
3.3
Mechanical Installation
The device is intended to be mounted through an M50 (50.5 mm) hole using the included sealing
ring and nut.
The top mounting surface (in contact with the sealing) must be flat with a finish equivalent to
Ra 3.2 or finer and cleaned and free from oils and greases.
Tightening torque:
5 Nm ±10 %.
Make sure that the sealing ring is correctly placed in the circular groove in the top part of
the housing before tightening the nut.
Always hold the BOTTOM part of the unit when untightening the nut, not the top part
(the cap).
Fig. 1
Installation drawing
All measurements are in mm.
Anybus
®
Wireless Bolt
™
User Manual