HMF-IRC Instruction Manual - GB
01-01
HMF TECHNICAL SERVICE DEP.
24
9.
Emergency Operation of the Loader
In case of IRC-system errors the following is indicated:
•
The ERROR diode on the electronic box flashes
•
The RUN and FUNC diodes on the RCL indicator panel are flashing
In this fault condition it is not possible to remote control the loader.
However, it is possible to change into emergency operation of the loader in the
following way:
•
On the RCL indicator panel, hold down the yellow
press button while pushing
the red press button
•
The RUN and FUNC diodes on the RCL indicator panel are still flashing
Now emergency operation of the loader is possible by using the control levers
on the valve block of the loader.
As a control of whether the system is set for emergency operation, it is possible
to push the red press button and the 100% diode will flash. If not, then change
into emergency operation again according to the above-mentioned procedure.
Please note:
In case of manual emergency operation of the loader, the
loader’s lifting capacity is reduced (the loader is derated) to 90% of its normal
capacity.
To change back into remote control mode, repeat the procedure stated above:
push/hold down the yellow press button and push the red press button.
10. The
HDL-System
(Option)
If the loader is equipped with an HDL system (Heavy Duty Lifting), it offers the
possibility of an increase of the loader’s nominal load by approx. 10 % while the
working speed is reduced.