background image

6

Display

Description

Troubleshooting

0

Loop is healthy

If experiencing problems with detection, reassess DIP switch settings or call 

HME* for guidance with settings.

1

Loop is in good condition

2

Loop is in moderate condition

3

Loop is approaching a critical 

condition

Severe weather may exacerbate problem. Loop replacement is 

recommended. Call HME* for guidance

4

Loop is close to failure

Severe weather may make the loop fail. Loop replacement is necessary.

5

Loop is healthy, but connection 

from the loop to the VDB103/

VDB103R is bad

Check electrical connections to loop and to VDB103/VDB103R as well as 

any cable splices. Call HME* if problem persists.

6

Loop is in good condition, but 

connection from the loop to the 

VDB103/VDB103R is bad

7

Loop is in moderate condition, but 

connection from the loop to the 

VDB103/VDB103R is bad

8

Loop is approaching a critical 

condition, but connection from the 

loop to the VDB103/VDB103R is 

bad

Check electrical connections to loop and to VDB103/VDB103R as well 

as any cable splices. Loop replacement is recommended. Call HME* for 

guidance.

9

Loop is close to failure, but 

connection from the loop to the 

VDB103/VDB103R is bad

Check electrical connections to loop and to VDB103/VDB103R as well as 

any cable splices. Loop replacement is necessary.

C

Loop Shorted

Disconnect loop from lead-in cable outside the building and re check. If still 
shorted, the cable is bad. If open (code “

d

”), loop replacement is indicated.

d

Loop disconnected from VDB103/

VDB103R

Check electrical connections at VDB103/VDB103R, loop, and any splices in 

the cable.

L

Loop inductance is outside of 

operable range

Schedule loop replacement.

U

Loop inductance is outside of 

range, and connection from the 

loop to the VDB103/VDB103R is 

bad

Check all electrical connections and re test. Loop replacement may be 

necessary.

F

VDB103/VDB103R has failed

Call HME* for replacement VDB103/VDB103R.

b

VDB103/VDB103R booting

Normal to appear for a few seconds after reset. Call HME* for replacement 

VDB103/VDB103R if code persists.

*1-800-848-4468

Figure 4. Loop Status Indication Table

SELF DIAGNOSTICS

If an abnormal condition with the loop or detector occurs, the LED display will show a number or letter (see below). Follow the 

recommendations appropriate for the code that is displayed.

Summary of Contents for VDB103

Page 1: ...A 9 23 19 HM ELECTRONICS INC 2848 Whiptail Loop Carlsbad CA 92010 USA Phone 1 800 848 4468 Fax 858 552 0172 Website www hme com Email support hme com VDB103 VDB103R Vehicle Detector Board Installatio...

Page 2: ......

Page 3: ...ESD Handling Instructions 2 Installation 3 Dip Switch Settings 4 Troubleshooting 5 Reset Procedure 5 Detector Function 5 Self Diagnostics 6 Regulatory Compliance Approvals 7 2019 HM Electronics Inc Th...

Page 4: ......

Page 5: ...ge must be placed on the side of either the Base Station or TSP depending upon which one of the two the VDB103 VDB103R board is installed in TSP Console Base Station Console The label may be placed on...

Page 6: ...es through analysis of loop response to a stimulus provided by the detector which characterizes the inductance of a loop The presence of a vehicle over the loop electromagnetically interacts with the...

Page 7: ...color coded connector wires must also match the pin positions shown on Figure 1 9 Connect the other end of the interconnect cable to the circuit board in the base station or control unit per installat...

Page 8: ...FF Normal VDB103 VDB103R Operation ON Detection is Suspended DSP firmware scrolls and car presence is cycled every 10 seconds On 10 seconds Off 10 seconds Switch 6 Switch 7 Delay OFF OFF 6 seconds OFF...

Page 9: ...ver the vehicle detector loop h h Press and hold the Reset switch in the base station or timer for 1 second and then release The VDB103 VDB103R display will go blank for a few seconds and then should...

Page 10: ...ent is recommended Call HME for guidance 9 Loop is close to failure but connection from the loop to the VDB103 VDB103R is bad Check electrical connections to loop and to VDB103 VDB103R as well as any...

Page 11: ...bject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation...

Page 12: ...ormit pour le Canada Cet appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est soumise aux deux conditions suivantes 1 cet appareil ne...

Page 13: ...ion about where you can drop off your waste equipment for recycling please contact your local authority your household waste disposal service or the seller from whom you purchased the product NCC Warn...

Reviews: