HME JTECH Staffcall IQ Paging User Manual Download Page 3

User Manual 

 

 

3

 

800.321.6221 

Staffcall IQ Pagers 

 

Model Number: STFIQ 

 

System Configurations 

System Default Configuration

 

The paging system was set to default settings listed below prior to shipment.   

 

Current time is set. 

 

Out of Range is set to OFF 

 

To enter programming mode, on the transmitter, press 

SETUP

, use password 

1379

 and press 

ENTER

.  

Use the 

*/MENU

 

button to scroll and the “

#/SELECT

 

button to choose the menu option.  

Once you have saved your changes, press 

CANCEL

 until you return to the main Pager Number screen. 

Set Current Time

 

1.

 

At the “

Set Current Time

” menu, press the “

ENTER

” key.

 

2.

 

Set the hour, then press the “

ENTER

” key.  

 

3.

 

Set the minutes, then press the “

ENTER

” key.      

 

4.

 

Use “

1 or 2

” key to select AM or PM, then press the “

ENTER

” key.   

 

5.

 

After the correct time is set, press the “

ENTER

” key to accept.  Press the “

CANCEL

” key to exit the system 

programming menu. 

Set Sleep Timer

 

This system has an “ALL SLEEP” function that turns off all battery pagers (for example, manager 

pagers) at once 

automatically.  

To turn Sleep Timer “

ON

”, follow the procedure below:

 

1.

 

At the “

Set Sleep Time

” menu, press the “

#/Select

” key to turn the sleep shutdown to “

ON

”.

 

2.

 

Press the “

ENTER

” key to accept the change.

 

3.

 

Press the “

CANCEL

” key twice to 

exit out of the menu. 

Change Shutdown Time 

1.

 

At the sleep shutdown menu, press the “

#/Select

” key to turn the sleep shutdown to “

ON

”.

 

2.

 

Press the “

ENTER

” key. 

 

3.

 

Set the hour then press the “

ENTER

” key.  

 

4.

 

Set the minutes and press the “

ENTER

” key. Use the “

1 or 2

” key to select AM or PM and then press the 

ENTER

” key. After the correct time is set, press the “

ENTER

” key to save. Press the “

CANCEL

” key to exit the 

system programming menu. 

 

To turn Sleep Timer “

OFF

”, follow the procedure below:

 

1.

 

At the “

Set Sleep Time

” menu, press the “

#/Select

” key to turn preset messages from “

ON

” to “

OFF

 

Summary of Contents for JTECH Staffcall IQ Paging

Page 1: ...800 321 6221 2017 JTECH an HME Company logo and product names are registered trademarks of HM Electronics Inc All rights reserved Part Number MPGCP 1 Staffcall IQ Paging User Manual Date 11 05 18...

Page 2: ...is recommended Compile charger bases and plug charger power supply into charger and then into a standard outlet Surge protection is recommended for charging bases Add pagers to charger slots You will...

Page 3: ...ey to accept Press the CANCEL key to exit the system programming menu Set Sleep Timer This system has an ALL SLEEP function that turns off all battery pagers for example manager pagers at once automat...

Page 4: ...er supply that is connected to the first charger 2 At the Out of Range menu press the Select key to turn the out of range OFF 3 Press the ENTER key 3 times After sending the signal all the pagers will...

Page 5: ...t up to 2 years with proper use Try charging the pager before considering replacement batteries If after 4 hours the pager charging light still displays amber contact JTECH to order replacement batter...

Page 6: ...ticularly those that deal with private land mobile radio services See 47 CFR Part 90 Changes or modifications not expressly approved by JTECH an HME Company may void the user s authority granted by th...

Page 7: ...y exposure guidelines the transmitter and antenna must be at least 8 inches 20 centimeters from any person Your radio generates radio frequency electromagnetic energy during transmission mode The radi...

Reviews: