HM3000CDM POLYTHENE HEAT SEALER
OPERATING INSTRUCTIONS
General
Before connecting the machine to the electricity supply, check the operating
voltage on the name plate attached to the base of the machine.
The wires in the mains lead are coloured in accordance with the following
code:-
Green & Yellow - Earth
Blue - Neutral
Brown - Live
Ensure that the machine is correctly earthed and connected to the mains
supply with a 5 amp fused plug.
The heating element operates at a reduced safety voltage and the machine
has its own 3.15 amp internal fuse, accessible at the rear of the body.
Installation
For transportation purposes the black handle has been fitted to the upper arm
in the reverse position. Before operating the machine this handle should be
fitted to the correct position.
Operating Instructions
Switch on the machine using the amber on/off switch on the side of the
machine. Check that the switch lights up to indicate that the machine is
powered.
The HM3000CDM impulse sealer is fitted with a dual electronic timer
controlling the heating and cooling cycles. When sufficient pressure is applied
to the pressure bar, the audible ‘click’ of the microswitch and the illumination
of the red LED indicator lights will confirm that the machine is correctly
adjusted and that power is being applied to heat up the element.
The heating time is variable between 0 and 3.5 seconds using the external
control knob. The cooling cycle is also adjustable to allow a sufficient cooling
time before the pressure bar is released.
Summary of Contents for HM3000CDM
Page 2: ......