The machine is adaptive in following situation
1. Applicable ambient temperature range:
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F.
3. If the fuse on PC board is broken please change it with the type of T.3.15A/250V.
4. The distance between the indoor unit and the floor should be more than 2m.
5. The wiring method should be in line with the local wiring standard.
6. After installation, the power plug should be easily reached.
7. The waste battery should be disposed properly.
8 .The wiring diagram is attached inside the machine.
Outdoor Unit
CONNECTING PIPING AND
ELECTRICAL WIRING
INLET
OUTLET
DRAIN HOSE
PARTS AND FUNCTIONS
Indoor
Maximum: D.B/W.B
32ºC
Cooling
Minimum: D.B/W.B
18ºC/14ºC
Outdoor
Maximum: D.B/W.B
43ºC/26ºC
Minimum: D.B
18ºC
Indoor
Maximum: D.B
27ºC
Heating
Minimum: D.B
15ºC
Outdoor
Maximum: D.B/W.B
24ºC/18ºC
Minimum: D.B/W.B
-7ºC/-8ºC