NOTE: This manual does not include Remote Controller Operations, see the <<Remote Controller
Instruction>> packed with the unit for details.
Operating temperature
Mode
Temperature
Cooling operation
Heating operation
Drying operation
Room temperature
17ºC ~ 32ºC
0ºC ~ 30ºC
10ºC ~ 32ºC
(<21000Btu/h models)
17ºC ~ 32ºC
(
≥
21000Btu/h models)
Outdoor temperature
18ºC ~ 43ºC
-7ºC ~ 24ºC
11ºC ~ 43ºC
(<21000Btu/h models)
-5ºC ~ 43ºC:
For the models
with low temperature cooling
system
18ºC ~ 43ºC
(
≥
21000Btu/h models)
21ºC ~ 52ºC:
For special
tropical models
21ºC ~ 52ºC
(For special tropical models)
NOTE:
1. If air conditioner is used outside of the above conditions, certain safety protection features may come
into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the
surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Manual operation
Manual operation can be used temporarily in case the remote controller is disable or maintenance necessary.
AUTO/COOL
Open and lift the front panel up to an angle until it
remains fixed with a clicking sound.
Push the button until the AUTO indicator is lit, the
unit will work in forced AUTO mode (the default
setting temperature is 24ºC).
Close the panel firmly to its original position.
CAUTION:
Once you push the manual button, the operation
•
mode is shifted in an order as: AUTO, COOL, OFF.
This is used for testing purposes only.
•
To restore the remote controller operation, use the
•
remote controller directly.