HITSA BORCH Technical Manual Download Page 6

HITSA BORCH Compressor Pump 

 

                       

SAFETY INFORMATION 

IMPORTANT: 

Read these instructions before product installation and operation

 

 

Before product installation and operation, please read the following safety 

information and sections in this manual concerning operation and installation. In 

addition to addressing safety concerns, reading this material will also help prevent 

damage to the product.  

 

Failure to install and operate this product in accordance with this information 

or using unauthorized spare parts could cause damage to the product and 

could result in severe bodily injury, including death in extreme cases. 

 

 
GENERAL SAFETY INFORMATION 

  If this product has been damaged, the power supply should be turned off 

immediately by a qualified service technician or electricity provider.  

  Only qualified service technicians should carry out service on this product.  

  Wear safety glasses, when servicing this product. 

  Compressed air can be dangerous; do not direct airflow at a person's head 

or body. 

 

 

TO REDUCE RISK OF ELECTRIC SHOCK 

  Do not use this product with electrical voltages other than those stated 

under Technical Specifications.  

  Do not install this product in any area where it will be subjected to above-

normal amounts of rainfall, other liquids, moisture, or areas subject to 

above-normal flood risk. 

  Do not attempt to service this product if it submerged in water. A qualified 

service technician or electricity provider should turn off the power supply to 

the product.  

 

TO REDUCE RISK OF EXPLOSION OR FIRE 

  Service and operate this product only in well ventilated areas. 

  During spraying with combustible liquids risk of explosion may arise, 

particularly in closed rooms. 

  Do not use this product in or near explosive atmospheres or where aerosol 

products are being used. 

  Do not use this product in or near areas with combustible or explosive 

liquids or vapors. 

  Do not use this product near naked flames. 

  Do not pump any other gases other than atmospheric air. 

  Do not pump combustible liquids or vapors with this product. 

 

 

Summary of Contents for BORCH

Page 1: ...BORCH Compressor Pump TECHNICAL MANUAL Rev B 08022022 RNH...

Page 2: ...INFORMATION 6 OPERATION 8 GENERAL USE 8 INSTALLATION 9 FOUNDATION 10 MOUNTING 11 INSTALLATION 12 ELECTRICAL 13 MAIN DIAGRAM OF THE AIR PUMP SYSTEM INTERNAL COMPONENTS 14 TECHNICAL SPECIFICATION 15 OV...

Page 3: ...ith these valve types and in addition to bicycles can be used for tires on items such as mopeds or children s carriages The pump compressor is factory set to a pressure of 8bar During inflation of a t...

Page 4: ...W External Components No Description 1 Pump Handle and hose 2 Start button 3 Manometer pressure gauge 4 Lock to remove cabinet front plate 5 Cabinet 6 Cabinet front plate removeable Table 1 Part descr...

Page 5: ...or compressor 4 Oil filler neck 5 Air filter 6 Compressor and air tank 7 Cabinet front plate 8 Manometer pressure gauge and T connector 9 Quick connector for pump handle hose 10 Start button connector...

Page 6: ...ct Compressed air can be dangerous do not direct airflow at a person s head or body TO REDUCE RISK OF ELECTRIC SHOCK Do not use this product with electrical voltages other than those stated under Tech...

Page 7: ...ion This product may only be connected to units or tools with a maximum pressure higher or equal to that of the compressor The surface of the compressor can get hot Do not touch compressor motor durin...

Page 8: ...or children s carriages 1 Push the start button table 1 item 2 on the front of the air pump to start the air pump system 2 Wait until the manometer table 1 item 3 shows sufficient desired air pressure...

Page 9: ...ng transportation installation or handling The electric compressor is oil filled and will leak when lying down If the pump has been on its side it must be checked for leaks cleaned inside and oil must...

Page 10: ...to mount the pump cabinet before concrete hardening using the cabinet to get desired height and leveling Fix it in this position until the concrete is hardened If the electrical wire is available at...

Page 11: ...e Figure 4 It is secured in place with four M8 x 25mm bolts and 4 M8 washers which connect into the base ATTENTION Be aware not to crush the caple It is recommended to use a M20 PG gand if cable is ro...

Page 12: ...gure 5a Connect the electrical connector from the pump to the socket on the electrical board above table 2 no 3 Install the cabinet front plate by connecting the air hose from the compressor table 2 n...

Page 13: ...d electricians ATTENTION Make sure that your air pump system is disconnected from the external power supply by turning off the Circuit breaker before changing plugging or unplugging any component insi...

Page 14: ...HITSA BORCH Compressor Pump 14 Main diagram of the air pump system internal components Figure 5 Main diagram of the air pump system components...

Page 15: ...HITSA BORCH Compressor Pump 15 TECHNICAL SPECIFICATION Overall Dimensions Figure 6 Overall dimensions...

Page 16: ...ssure 8bar 116psi Factory setting 8bar Noise in application 40dB Run time down time Max 15min 10min Tank capacity 4L Filling rate 18 5 L min The compressor contains oil and drains humidity automatical...

Page 17: ...n to adjust the timer to approximately 5minutes The pump does not start when pushing the start button The external HPFI relay may have been turned off Check that the ON OFF switch on the compressor in...

Page 18: ...When the HPFI switch located in the fuse box Figure 1 item 2 is switched on 1 it must trip when the test button Test is pressed Remove dirt from the cabinet with detergent For regularly cleaning deter...

Page 19: ...lketon MEK the surface may not be rubbed more than maximum 4 5 times during each application Repairing minor damage 1 Gently sand damaged area without damaging coating further 2 Remove loose particles...

Page 20: ...y of replacement depends on use patterns specific to each product installation location To order spare parts or enquire about service options please contact HITSA through the contact information found...

Page 21: ...To maintain warranty coverage all product servicing must be completed by a HITSA Service Partner or by a certified professional HITSA reserves the right to modify technical specifications and offer al...