13
CONTROL AND CONNECTIONS/DAY&NIGHT
I/O / ALARM OUT TERMINALS
1
2
3
4
5
6
7
8
UTP-
(optional)
UTP+
(optional)
D&N I/O
COM
ALARM
RS-485
IN
OUT
GND
OUT
RS-485+(RX)
RS-485-(TX)
1)
UTP Connections/Video output (optional)
● 1 PIN: UTP-
● 2 PIN: UTP+
2)
DAY&NIGHT I/O Terminals
To select Day/Night mode using external equipment, by connecting control lines
to the appropriate terminals.
●
DAY&NIGHT OUTPUT (4pin)
Is the camera function that can turn on an external IR LED Lamp by detecting the
sensitivity on the AGC level when the D&N mode is set "AUTO" on the OSD menu of the
camera
●
DAY&NIGHT EXTERNAL INPUT (3pin)
Is the camera function that can be switched to DAY Mode or NIGHT mode by receiving
the D&N on/off signal from external light sensor or IR LED LAMP. This needs the D&N
Mode to be set to "External" on the OSD menu of the camera to work
3)
ALARM OUT (6pin)
Motion detection signals are output through this port. Active state is configurable.
4) POWER INPUT TERMINAL
●
This terminal accepts a DC12V or AC24V power
source from a DC12V or AC24V ac +/-10%
60/50Hz +/- 1Hz.
●
Use Certified/Listed Class 2 power supply only.
●
It is recommended to use the DC power supply that can
support inrush current over 0.75A
●
AC Power Cord - This power cord accepts a
100-240V ~ 50Hz +/- 1Hz
5)
CAMERA CONTROL
● 7 PIN: RS 485+
● 8 PIN: RS 485-
4 DAY&NIGHT OUTPUT
5 COM
5 COM
3 DAY&NIGHT INPUT
CLASS 2
+ DC 12V -
~ AC 24V ~
AC 100-240V
● 5V/10mA : IR LED ON (NIGHT)
● 0V : IR LED OFF (DAY)
Open contact: DAY
Close contact: NIGHT