![HITROL HT-100R Series Instruction Manual Download Page 24](http://html.mh-extra.com/html/hitrol/ht-100r-series/ht-100r-series_instruction-manual_2140204024.webp)
■
Definition of Height
■
Zero, Span Quick Setting
□ Unit Setting Screen
※ Factory shipping is set as “[%] unit setting”.
□ Zero Setting
No.
Content
Quick Menu Setting
[02]
Zero Setting
Press for 1 sec. Input the value Press for 1 sec.
□ Span Setting
No.
Content
Quick Menu Setting
[03]
Span Setting
Press for 1 sec. Input the value Press for 1 sec.
□ Others
Zero / Span can be set regardless of Display Mode status.
It can set, save, or cancel the values. (Refer to
Table 3. Key Button Guidance
)
The level of medium state shall be maintained when setting zero / span.
Criterion of Level
: The direction in which the medium
is raised based on the bottom of the tank.
Zero Height: The height from bottom of tank to center
of float at zero position.
Span Height: The height from bottom of tank to
center of float at span position.
Tank Height: The height from bottom of tank to
highest level of medium in the tank.
Distance: The length from top of tank to center of float.
Criterion of Distance
: The direction in which the
medium is lowered based on the top of the tank.
Crit
erion
of
Le
ve
l
Cri
te
rion
of
Di
st
ance
Unit Setting
Unit Setting