background image

 

 

HM-30, 90 Series 

 

 

        HITROL CO., LTD.                                                                                15 

 

■  Check the level and presence of measure object in the tank before removing it. 

■  Wear gloves when removing it, to prevent a burn. 

■  If there is explosive gas atmosphere, do not open the cover. 

■  Make  sure  that  any  O-ring  or  gasket  is  not  damaged  while  opening  or  closing  the 

cover of product. 

■  Unlock the lock key before removing the cover. 

■  Disconnect the cable before removing the snap switch. 

 

■  Pay special attention to prevent any impact on the device during transportation or assembly. 

■  Pay  attention  to  prevent  any  damage  to  any  packing  when  transporting  or  mounting 

the machine to the vessel. 

 

Make sure that it is not subject to any high impact when moving the product. 

■  External ground is located on top of cable entry, and the grounding wire to connect external 

ground must be 4㎟  (4mmSQ). (Internal ground is connected before shipment.) 

Make sure to insert a washer if the terminal lug is removed from the ground terminal 

and then re-connected.(Loosening prevention) 

■  Use the cable gland connection or metal pipe line lead-in on the wire inlet, and use a product 

with equivalent Ex-proof certificate to connect it with the external line lead-in method. 

■  For non-use external wire inlet, use a closed plug that passes safety certificate above equivalent 

performance with the product.  

 

 

 

 

 

 

Precautions 

for 

Removal 

 

 

 

 

 

 

Precautions 

for 

Transportation 

and Assembly 

 

 

 

 

 

Precautions 

for 

Grounding 

 

 

 

 

 

 

Precautions 

for 

Inserted 

External 

Wire 

(Ex-proof) 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HM-30 Series

Page 1: ...2 Issue date 2020 08 HITROL CO LTD HEAD OFFICE FACTORY R D INSTITUDE HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea TEL 00 82 31 950 9700 FAX 00 82 31 943 5600 www hitrol com INSTR...

Page 2: ...cess Condition Rating 5 ProductConfigurationandTechnicalData 5 Dimensions and Detailed Technical Specifications 6 Weather Proof Version 6 Ex Proof Version 8 Contact Form 9 Guide Pipe Version 10 Chambe...

Page 3: ...is submerged when the level of measure object rises it becomes lighter because of the buoyancy where the spring that was compressed by the weight of displacer is released so the core rises within the...

Page 4: ...Type Snap Switch Hermetical Sealed Switch Process Connection 50A JIS 10K FF 6T 80A JIS 10K RF Std Material Displacer SUS 304 SUS 316L Chamber N A C S SUS 304 SUS316L Others Cable Entry C S PF 3 4 F AL...

Page 5: ...is suitable for application B Good Theproductcanhandletheconditions butitmaybeaffectedbyperformance soitshouldbenotedformaintenance Cleaning C Poor The product does not meet the conditions Carbon Stee...

Page 6: ...y occur with actual products Dimensions and Detailed Technical Specifications The dimensions on the following pages are indicated in mm Process Temp 120 C 200 C 350 C 500 C 500 C Opt C S Aluminum Hous...

Page 7: ...M 30 90 Series HITROL CO LTD 7 Some tolerances may occur with actual products Process Temp 120 C 200 C 350 C 500 C 500 C Opt Aluminum Housing S W 1ea Aluminum Housing S W 2 3ea Aluminum Housing S W 4e...

Page 8: ...90 Series HITROL CO LTD 8 Ex Proof Version Some tolerances may occur with actual products Process Temp 120 C 200 C 300 C 350 C Aluminum Housing S W 1ea Aluminum Housing S W 2 3ea Aluminum Housing S W...

Page 9: ...HM 30 90 Series HITROL CO LTD 9 Contact Form Some tolerances may occur with actual products 1F 2F 1F 2F...

Page 10: ...HM 30 90 Series HITROL CO LTD 10 Guide Pipe Version Chamber Version Some tolerances may occur with actual products HM 90A HM 90B...

Page 11: ...because of buoyancy when the level of rises and the displacer is submerged The magnet which is connected with the switch responds to trigger the switch when the core rises Switch Specifications by Pro...

Page 12: ...e terminal COM N O of the switch block For H L Control connect to COM N C for water supply control and COM N O for water drainage control The housing is designed to prevent damage from dust or water a...

Page 13: ...ing the connection and main unit must be leveled and it is recommended to install a bracket to support the product if necessary proof rating and fluid temperature before applying an Ex the temperature...

Page 14: ...ess connection If there is a problem with operation check the followings first Remove the cover and check the output contact of snap switch Check the output by connecting COM with N O or N C using a t...

Page 15: ...ake sure that it is not subject to any high impact when moving the product External ground is located on top of cable entry and the grounding wire to connect external ground must be 4 4mmSQ Internal g...

Page 16: ...high temperature products To prevent damage to the cable An Ex proof product is a pressure resistant and Ex proof type so never open the cover during operation Ex proof products are designed according...

Page 17: ...ontact Number ADRESS HITROL CO LTD 141 Palhakgol gil Jori eup Paju si Gyeonggi do Korea T E L 031 950 9700 Headquarters A S F A X 031 943 5600 Headquarters A S Do not apply a Non ex proof product in a...