INTRODUCTION 

 

This installation and maintenance booklet should always accompany the air tre- 

atment unit for ready consultation by the installer or user if necessary. The unit 

should be installed in compliance with the regulations in force in each country 
and according to the manufacturer’s or qualified person’s instructions. The ma- 
nufacturer cannot be held liable for any damage to property or injury to persons 

and animals caused by incorrect installation of the unit. Only qualified persons 

should install the unit and connect it to the mains electricity supply. Before car- 

rying out any work on the unit, ensure that it is disconnected from the electricity 

supply. Read this instruction booklet prior to installation.

 

 
 

 

RECOMMENDATIONS 

 

This unit is easy to use, but it is important to read all the contents of this guide

 

before using it for the first time. This will help you to:

 

- use the unit in all safety

 

- obtain best performance

 

- avoid incorrect actions

 

- respect the environment

 

- Do not allow children or unassisted handicapped persons to use the unit.

 

- Do not touch the unit with wet parts of the body or if barefoot.

 

- Do not tug, pull or twist electrical cables attached to the unit, even when di- 

sconnected from the electricity supply.

 

-  Do  not  open  the  flaps  giving  access  to  the  internal  parts  of  the  unit  without 

having first put the system on-off switch to 

“off”.

 

- Do not introduce sharp pointed objects through the air intake and outlet gril- 

les.

 

- Do not leave packing material (boards, staples, plastic bags, etc.) within reach 

of children since they could be a source of danger. Dispose of correctly.

 

- Do not spray or throw water directly on the unit.

 

-  Do  not  use  the  unit  in  places  with  suspended  dust/powder  or  in  potentially 

explosive atmospheres, in very damp environments or in the presence of oil in 

suspension or in particularly aggressive atmospheres.

 

-  Do not cover the unit with objects or drapes that even partially obstruct the

 

air flow.

 

The unit works by electricity at mains voltage (230 Vac, 50 Hz). Always bear in 

mind that mains voltage is potentially dangerous and any appliance connected 

to  it  should  be  used  with  caution.  Before  carrying  out  any  work  on  the  unit, 

disconnect it from the electricity supply (by pulling out the plug from the mains 

socket or isolating the supply line by putting the on-off switch OFF. If the unit is 

not be used for long periods, make sure that the controls are in the position 0 

(off). If the unit is not going to be used in winter when temperatures are near to 

freezing, drain the system and ensure that the unit heat exchanger has no water 

in it in order to prevent the formation of ice and consequent breakage. To make 

the unit inoperable, disconnect it totally from the electricity supply. It is unsafe 

to alter or try to alter the characteristics of this product. Any tampering or alte- 

ration in any case makes the warranty null and void. In the event of malfunction 

or  failure,  do  not  try  to  repair  the  unit  yourself;  contact  a  qualified  technician. 

Repairs carried out by incompetent persons could cause damage or accidents. 

Always keep the unit clean. In particular clean the air filter periodically (at least 

once a month).

 

 

FAILURE  TO  COMPLY  WITH  THE  ASSEMBLY  INSTRUCTIONS  GIVEN  IN 

THIS  GUIDE  RELIEVES  THE  PRODUCER  OF  ALL  AND  ANY  LIABILITY. 

INCORRECT INSTALLATION COULD CAUSE MALFUNCTIONING OR FAI- 

LURE OF THE UNIT. IT COULD ALSO REPRESENT A HAZARD FOR THE 

USER.

 

IDENTIFICATION OF THE UNIT 

 

The air treatment units come with a rating plate, which shows:

 

 

 

- The manufacturer's address;        - Supply voltage in "V";

 

- "CE" marking; 

- Supply frequency in 

“Hz”;

 

- Model; 

- Number of phases, indicated with "Ph";

 

- Lot number; 

- Total cooling capacity in 

“W”;

 

- Date of production; 

- Sensible cooling capacity in 

“W”;

 

- Rated absorbed current in "A";     - Heat output.

 

- Input in 

“W”;

 

 

TRANSPORTATION, RECEIVING, HANDLING 

 

The units and their accessories are enclosed in cardboard boxes up to size 50, 

while the other sizes are palletised. The packs should be kept intact until positio- 

ned in the final place of installation. Use suitable handling equipment according 

to the  weight of the  unit, as provided for  by  directive 89/391/EEC and subse- 

quent amendments. The  weight of  each single machine is given in this  guide 

(table 2). Upon receiving the unit, check all the parts for any damage caused in 

transit. Any damage  should  be  reported to the carrier by  affixing  an accepted 

with reservation on the accompanying note, specifying the type of damage. In 

the  event  of  prolonged storage, keep the  units protected  against dust  and far 

from sources of vibration or heat. The number of units that may be positioned 

on one pallet are given in the table (table 1).

 

 

THE  PRODUCER  CANNOT  BE  HELD  LIABLE  FOR  DAMAGE  DUE  TO  IN- 

CORRECT  HANDLING  OR  LACK  OF  PROTECTION  AGAINST  THE  ELE- 

MENTS.

 

SAFETY PROVISIONS 

 

 

Secure packs during transportation. 
Do not expose to the elements.

 

Do not tread on packs.

 

 
 

Protect hands with work gloves when dismantling the unit. 
Work in PAIRS if the appliance weighs more than 25 kg.

 

Summary of Contents for BSW 1

Page 1: ...Rev 102 1 BSW Cooling only FAN COIL HIGH PRESSURE Models 1 2 3 4 5 6 7 Cooling capacities from 3 8 to 50 6 kW Heating capacities from 5 0 to 60 9 kW 06 18 Ref 207483 Rev 102 INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Page 2: ...BSW FAN COIL HIGH PRESSURE 2 06 18 Ref 207483 Rev 102 ...

Page 3: ...LY DIAGRAM 10 PAM MOUNTING BRACKET ASSEMBLY DIAGRAM 11 RAM MOUNTING BRACKET ASSEMBLY DIAGRAM 11 GAM ASSEMBLY DIAGRAM 12 SRE ASSEMBLY DIAGRAM 12 SRA ASSEMBLY DIAGRAM 13 USG ASSEMBLY DIAGRAM 13 SSP ASSEMBLY DIAGRAM 14 ALUMINIUM DAMPER ASSEMBLY DIAGRAM 14 BAM ON PAN ASSEMBLY DIAGRAM 15 BAM ON RAM ASSEMBLY DIAGRAM 15 SUPPLY GRILL ON PAM ASSEMBLY DIAGRAM 16 SUPPLY GRILL ON RAM ASSEMBLY DIAGRAM 16 INTAK...

Page 4: ...ed for long periods make sure that the controls are in the position 0 off If the unit is not going to be used in winter when temperatures are near to freezing drain the system and ensure that the unit heat exchanger has no water in it in order to prevent the formation of ice and consequent breakage To make the unit inoperable disconnect it totally from the electricity supply It is unsafe to alter ...

Page 5: ... 656 956 1156 1306 1406 B mm 253 253 303 328 353 M mm 680 980 1180 1330 1430 C mm 247 247 297 322 347 D mm 237 237 237 300 5 300 5 E mm 118 118 118 195 195 F mm 93 5 93 5 118 5 131 143 5 G mm 233 233 233 310 310 I mm 83 5 83 5 108 5 121 133 5 N mm 193 193 193 270 270 Fittings male 2 rows coil Ø 1 2 1 2 3 4 3 4 1 4 rows coil Ø 1 2 3 4 3 4 1 1 6 rows coil Ø 3 4 3 4 1 1 1 1 4 Net weight kg 28 38 49 6...

Page 6: ...7 MOD 6 7 L mm 2190 2190 H mm 373 398 P mm 770 770 A mm 2076 2076 B mm 328 353 M mm 2100 2100 C mm 323 348 D mm 300 5 300 5 E mm 201 5 201 5 F mm 131 5 144 G mm 311 311 I mm 121 5 134 N mm 270 270 Fittings male 2 rows coil Ø 1 1 4 rows coil Ø 1 1 4 1 1 2 6 rows coil Ø 1 1 2 1 1 2 Net weight kg 127 Pic 02 ...

Page 7: ...ply line Drill the holes in line with the relative slots for the 6 unit screw anchors Pic 4 Inject thermosetting resin into the holes and then insert the screw anchors Pic 5 Fix the threaded rods of the correct length to the screw anchors Pic 5 and insert them into the relative slots Pic 6 After having created a slope max 3 cm m in the direction of the condensate outlet lock the threaded rod with ...

Page 8: ...8 Ref 207483 Rev 102 EXAMPLE OF ACCESSORIES USE AND COMPATIBILITY UNIT PAM RAM GAM SRE SRA USG SSP Aluminium damper BAM Air intake grill Air supply grill Depending on the requirements the air filter can have a thickness of 12 25 48 mm ...

Page 9: ...LENUM ASSEMBLYDIAGRAM PAM INTAKEPLENUM ASSEMBLYDIAGRAM SCREWS LEGEND PAM 1 5 x8 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 SCREWS LEGEND PAM 6 7 x10 Screw TC M5x12 UNI7687 x6 Hex nut M5 flangiato with corrugated washer DIN4161 Pic 07 ...

Page 10: ...TE M5x12 UNI 5739 TE M5x12 SCREWS LEGEND RAM 6 7 x6 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 x4 Screw TE M5x12 UNI 5739 Pic 09 SCREWS LEGEND RAM 1 5 x7 Screw TC M5x12 UNI7687 TE M5x12 x6 Hex nut M5 flanged with corrugated washer DIN4161 x1 Screw TE M5x12 UNI 5739 SCREWS LEGEND RAM 6 7 x8 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 ...

Page 11: ... 207483 Rev 102 11 PAMMOUNTINGBRACKETASSEMBLYDIAGRAM RAMMOUNTINGBRACKETASSEMBLYDIAGRAM SCREWS LEGEND 1 5 x6 Self drilling screw with tip TC 3 9x9 5 UNI6954 Pic 11 SCREWS LEGEND 1 5 x6 Self drilling screw with tip TC 3 9x9 5 UNI6954 Pic 12 ...

Page 12: ... 102 GAMASSEMBLYDIAGRAM SREASSEMBLYDIAGRAM SCREWS LEGEND SRE 1 5 x8 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 SCREWS LEGEND SRE 6 7 x10 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 Pic 14 ...

Page 13: ...2 13 SRAASSEMBLYDIAGRAM USGASSEMBLYDIAGRAM SCREWS LEGEND SRA 1 5 x8 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 SCREWS LEGEND SRA 6 7 x10 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 Pic 15 ...

Page 14: ...AGRAM CANALIZABLE SIDE Lined up to the edge SCREWS LEGEND SSP 1 5 x8 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 UNIT ACCESSORIES SIDE Shorter to mix the air flow SCREWS LEGEND SSP 6 7 x10 Screw TC M5x12 UNI7687 x6 Hex nut M5 flanged with corrugated washer DIN4161 Pic 17 ...

Page 15: ... BAM ON PANASSEMBLYDIAGRAM BAM ON RAMASSEMBLYDIAGRAM SCREWS LEGEND 1 5 x8 Screw TC M5x12 UNI7687 x8 Hex nut M5 flanged with corrugated washer DIN4161 SCREWS LEGEND 6 7 x10 Screw TC M5x12 UNI7687 x10 Hex nut M5 flanged with corrugated washer DIN4161 Pic 19 ...

Page 16: ...RAM SUPPLYGRILLON RAMASSEMBLYDIAGRAM SCREWS LEGEND 1 5 x6 Self drilling screw TC 4 2x13 UNI8118 SCREWS LEGEND 6 7 x8 Self drilling screw TC 4 2x13 UNI8118 Pic 21 SCREWS LEGEND 1 5 x6 Self drilling screw TC 4 2x13 UNI8118 SCREWS LEGEND 6 7 x8 Self drilling screw TC 4 2x13 UNI8118 Pic 22 ...

Page 17: ...RAM INTAKE GRILL ON RAMASSEMBLYDIAGRAM SCREWS LEGEND 1 5 x6 Self drilling screw TC 4 2x13 UNI8118 SCREWS LEGEND 6 7 x8 Self drilling screw TC 4 2x13 UNI8118 Pic 23 SCREWS LEGEND 1 5 x6 Self drilling screw TC 4 2x13 UNI8118 SCREWS LEGEND 6 7 x8 Self drilling screw TC 4 2x13 UNI8118 Pic 24 ...

Page 18: ... of the water in the trap Upon completion of work check that the condensate flows out properly by pouring water into the tray The condensate water drainage system should be fabricated in a workmanlike manner and should be periodicallychecked The manufacturer cannot be held liable for any damage caused by dripping in the absence of a valve or of periodic maintenance of the drainage system ELECTRICA...

Page 19: ...BSW FAN COIL HIGH PRESSURE 06 18 Ref 207483 Rev 102 19 WIRING DIAGRAM MOD 1 3 ...

Page 20: ...BSW FAN COIL HIGH PRESSURE 20 06 18 Ref 207483 Rev 102 WIRING DIAGRAM MOD 4 5 ...

Page 21: ...BSW FAN COIL HIGH PRESSURE 06 18 Ref 207483 Rev 102 21 WIRING DIAGRAM MOD 6 7 ...

Page 22: ...ND MAINTENANCE CAUTION Before carrying out any cleaning or maintenance work disconnect the unit from the mains electricity supply ROUTINE MAINTENANCE The user is duty bound to have all maintenance operations carried out by trai ned and qualified personnel only If the unit has to be dismantled protect hands with work gloves Monthly checks Ensure that the fan impellers are clean If they are dirty cl...

Page 23: ...as before Check that the filter and the coil are clean no air has entered the water circuit by bleeding from the relative valve the installation is correctly balanced the boiler chiller is in proper working order DISMANTLING THE UNIT This unit is made to last for many years Qualified personnel are needed to dismantle it in all safety The first operation to be carried out before dismantling the uni...

Page 24: ...BSW FAN COIL HIGH PRESSURE 24 06 18 Ref 207483 Rev 102 NOTES ...

Page 25: ... 18 Ref 207483 Rev 102 25 HIPLUS AIRE ACONDICIONADO S L Masia Torrents 2 Tel 34 93 893 49 12 Fax 34 93 893 96 15 08800 Vilanova i la Geltrú Barcelona Spain www hitecsa com We reserve the right to change specification without notice ...

Reviews: