Lithium
Additional Features & Settings
Press the
►
button once to and the timer value will
begin fl ashing. Use the
✚
or
▬
buttons to change the
timer value. The timer can be set between 5 and 60 min. We strongly recom-
mend that the timer be set to 10 minutes or less.
Press
►
to set the Battery Check Timer.
NiMH Sensitivity shows the cutoff voltage for the automatic charge termination
of a NiMH battery. The eff ective setting ranges from 5 to 20mV per cell. If the
trigger voltage is set higher, there is a danger of overcharging the battery; if it
is set lower, there is a possibility of premature termination. Please refer to the
technical specifi cations of the battery (NiMH default: 7mV).
See pg. 28 for instructions on accessing the “
NiMH
Sensitvity
“ screen.
Press the
►
button once and the voltage value will
begin fl ashing. Use the
✚
or
▬
buttons to change the
voltage value. The voltage can be set between 5mV and 20mV.
Press
►
to set the voltage.
NiCd Sensitivity shows the cutoff voltage for the automatic charge termination
of a NiCd battery. The eff ective setting ranges from 5 to 20mV per cell. If the
trigger voltage is set higher, there is a danger of overcharging the battery; if it
is set lower, there is a possibility of premature termination. Please refer to the
technical specifi cations of the battery (NiCd default: 12mV).
See pg. 28 for instructions on accessing the “
NiCd
Sensitvity
“ screen.
Press the
►
button once and the voltage value will
begin fl ashing. Use the
✚
or
▬
buttons to change the
voltage value. The voltage can be set between 5mV and 20mV.
Press
►
to set the voltage.
Battery Check Timer (cont.)
NiMH Sensitivity
NiMH Sensitivity
LiPo/LiIo/LiFe
CHK Time 10min
NiMH Sensitivity
D.Peak Default
NiCd Sensitivity
D.Peak Default
NiMH Sensitivity
D.Peak 7mV/cell
NiCd Sensitivity
D.Peak 12mV/cell