Menu Maintenance
TLS
By selecting the TLS menu it is possible to make the TLS determination measurements,
depending on the TLS mode.
Depending on the chamber which is currently set in the DADS application different windows
appear.
Target Value Mode Measurement.
70% mode measurement.
In the Manual Mode, no TLS measurement can actually be done. A window is just
showing the manual TLS value. This value can be changed in the chamber
configuration, in the HITEC Config application.
Also refer to TLS Modes to get more information on the different modes which the DADS can
work with.
Target Value Mode
In the Target value mode in the following window will appear by choosing the Maintenance /
TLS menu. See also TLS Measurement section to get more information about the principle
of the TLS.
With this window it is basically possible to make TLS measurement or to view the latest
measurements which have been made.
Figure 7
– TLS in Target Value Mode