18
Charger Operations Continued
LP3s 1.5A 12.14V
BAL 000:50 00022
Program Stop:
You can press the STOP at anytime throughout the charge
or discharge process to stop the process
Program Complete:
The charger will indicate that the process is “FINISHED” and
play an audible notification.
CHARGE FINISHED
Information Displayed While Operating
Pressing INC or DEC during the charging or discharging process allows the user to scroll through a variety of
information on the LCD screen.
LP3s 1.5A 12.14V
BAL 000:50 00022
→→
→→
→→
INC
►
INC
►
INC
►
Real-time status: battery type, battery cell, charge current, battery voltage,
elapsed time and charged capacity.
Voltage of each cell in the battery pack when the battery is connected
with balance lead.
Charged capacity percentage and average cell voltage of the battery pack.
3.796V 3.798V
3.813V 0.000V
Fuel= 90%
Cell =
4.10V
If both numbers are identical, press START/ENTER to begin the
charging process.
The charger will perform a quick check to detect the number of cells.
R
shows the number of cells detected by the charger while
S
is the
number of cells set by the user. If the numbers are not identical, press
STOP to go back to the previous screen and recheck the number of cells
in the battery pack before proceeding. If they are correct, the charger
will begin the process
Program Start:
Press and hold START/ENTER for 3 seconds to start the
program.
→
LiPo BALANCE
2.0A 11.1v (3s)
START
/
ENTER
> 3 S
ECONDS
BATTERY CHECK
WAIT
R:
3SER
S:
2SER
CANCEL (STOP)
R:
3SER
S:
3SER
START (Enter)
OR