SLEEP

SLEEP

9

(

9000Btu/h Models)

(

9000Btu/h Models)

SLEEP:

Activates the "AUTO" (if applicable), 

OOL",

 "DRY" function.

"HEAT" (if 

applicable), "C

"FAN"or

Activates the  auto START  or  auto STOP
program from 0-12 hours (1 hour increments).

"

"

"

"

Activates the  SLEEP  mode.

"

"

Activates the automatic air  SWING  (vertical)
louver oscillation) feature.

"

"

Activates the  FAN  speed settings (HIGH, MED, 
LOW).

"

"

EI=CLEAN AIR FILTER:

A message prompt  EI  will automatically appear in 
the LED window indicating when it is time to clean 
the air filter. The 

program is a (built-in) time 

device that operates based on total (air conditioner)
running time. It is very important to keep the air filter
clean at all times in order to maximize cooling 
efficiency (See Cleaning Air Filter). The air filter 
must be cleaned when the  EI message from the 
LED display, the air conditioner must be switched 
off and disconnected (unplugged) from the power 
supply and re-connected. 

" "

"

EI

" " 

This action automatically 

resets  the 

"

EI

"

 program internal time device.

In the event of a power failure, the  EI  program is 
automatically re-set, therefore we suggest you 
remove and clean the filter before re-starting the 
unit after any power failure.

" "

NOTE:

Indicates frosting protection (Turn off the unit and 
restart it to return to normal operation).
Indicates the requirement of a filter check after 720
hours of fan operation. Turn off the unit, 
disconnect/unplug from the power supply. Clean the 
filter, then restore the power, the unit will return to 
normal operation. 

Failure Indicator Display:

      

Indicates a malfunction of the indoor room

        temperature sensor 
        Indicates a malfunction of the evaporator 
        temperature sensor
        Indicates a malfunction of the outdoor condenser 
        temperature sensor

Remote Control functions:

The hand held remote control unit allows you to control
all operational aspects of your Air Conditioner, from the
convenience of your favorite armchair. Here are some
things you should know about operation your Air 
Conditioner with the hand held remote control.

TEMP:

Increases / Decreases operating  TEMPERATURE  
only.

"

"

POWER:

Turns the power to the main unit 

  only.

"on/off " 

MODE:

TIMER:

SWING:

FAN:

Batteries:

To operate the hand held remote control, you will
require two  AAA  1.5Volt batteries (included).
NOTE: Batteries should be replaced when:
a) No signal (beep) is heard from the main unit when
    initiating program commands from the remote
    control to the main unit.
b) The main unit does not respond to the remote 
     control program commands.

"

"

Note:

 

When one of the above malfunctions occurs, 

             turn off the unit, and check for any obstructions. 
             Restart the unit, if the malfunction is still 
             present, turn off the unit and unplug the power 
             cord. Contact the manufacturer or its service 
             agents or a similar qualified person for service.

Battery Replacement:

1) Slide the lower (battery) cover down (Located on
    rear of remote control unit).
2) Insert two 

"

AAA

"

 Batteries inside the battery

    chamber (as depicted inside the battery chamber).
3) Re-install lower battery cover.
4) If the remote control is not being used for extended
    time periods, (vacation, off season) the batteries 
    should be removed from the remote control unit.

Summary of Contents for WINDOW/WALL TYPE ROOM AIR CONDITIONER

Page 1: ...ture reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW WALL TYPE ROOM AIR CONDITIONER Before using your air conditioner please read this manual carefully a...

Page 2: ...If you review our chart of Troubleshooting Tips first you may not need to call for service at all Contact the authorised service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play w...

Page 3: ...e fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric shock It may cause fire and electric shock It may cause electric shock or fire If the power cord is damaged it must be replaced by the manufac turer or an authorised service centre or a s...

Page 4: ...es food pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not using the unit for a long time If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified service techn...

Page 5: ...om when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g Preserving precision devices food pets plants and art objects Usage in such a manner could harm such property 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the ...

Page 6: ...hed The wall outlet should be provided with reliable earth wire 4 The unit should be provided with an individual circuit and the circuit breaker fuse rating should be the same as that of the power cord and wall outlet 1 Front panel 2 Air filter 3 Frame 4 Cabinet 5 Air inlet grille outdoor side 6 Air outlet grille 7 Electronic control keypad 8 Power supply cord and plug 9 Remote control 5 UNIT PART...

Page 7: ... Models The vent control is located above the control knobs The operation method is different on different models see the following figures For maximum cooling efficiency CLOSE the vent This will allow internal air circulation OPEN the vent to discharge stale air The electronic control keypad will look like one of the following CLOSE VENT OPEN To open the vent pull the lever toward you To close it...

Page 8: ...s Scale Minimum Setting 16 C FAN Press this keypad to activate the appropriate fan speed setting Each depression of the keypad will alternate through LOW MED HIGH fan speed options The green indicator light beside the FAN speed option will illuminate identifying the fan speed selected SWING Press the SWING keypad 9000Btu h models only to activate the automatic air swing oscillation feature The gre...

Page 9: ...f the actual room temperature is 2 C above the set point the unit operates in cooling mode When the actual room temperature O O is not 2 C or higher above the set point and not 1 C or lower below the set point the unit O will select the FAN mode When the actual room temperature is 2 C below the set point the unit will operate in HEAT mode Note If activating the SLEEP mode when the unit is operatin...

Page 10: ...n to normal operation Failure Indicator Display Indicates a malfunction of the indoor room temperature sensor Indicates a malfunction of the evaporator temperature sensor Indicates a malfunction of the outdoor condenser temperature sensor Remote Control functions The hand held remote control unit allows you to control all operational aspects of your Air Conditioner from the convenience of your fav...

Page 11: ... mode the heating temperature set point will O decrease 1 C per hour after the mode is selected Two hours later the set point will continue at this temperature and the fan motor remain on LOW speed Using the SLEEP mode will reduce noise creating a comfortable sleeping environment TIMER Press the TIMER button to activate the auto start auto stop timer function Auto start stop programs can be set fr...

Page 12: ... in the same direction as the opening 4 Clean the filter with warm soapy water The water O should be below 40 C to prevent distortion of the filter 5 Rinse off and gently shake off excess water from the filter Allow the filter to dry before replacing it To prevent distortion of the filter do not dry in direct sunlight To meet different requirement of different type of air conditioner there are two...

Page 13: ... 150cm above the floor level 6 The power cord must be connected to an independent circuit The yellow green wire must be grounded Over 50cm About 10mm FENCE AWNING 75 150mm Over 50cm About 10mm FENCE AWNING 75 150mm All side louvers of the cabinet must remain exposed to the outside of the structure CAUTION Select the best location INSTALLATION INSTRUCTIONS For Reverse Cycle Models You can choose bo...

Page 14: ...RICK CUT AWAY TO CLEAR LOUVRES FRONT AIR OUT AIR IN AIR IN TOP VIEW O 45 BRICK CUT AWAY TO CLEAR LOUVRES 100mm BRICK WALL 100mm OPTION B Step 1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to Installation Steps Step 2 Prepare the hole in the wall so that the bottom of the housing is well supported the top has minimum cl...

Page 15: ...binet See Fig 8 5 Install the two chassis fixing brackets using the two fixing screws See Fig 5 Step 4 Install the frame 1 Install the frame and connect the coupler plugs making sure not to interfere with the temperature sensor cable See Fig 9 2 Fix the screws on the frame See Fig 3 Step 5 Install the air filter and front panel 1 Install the air filter into the frame s slot from upside to undersid...

Page 16: ...compressor has cycled off The fuse is blown circuit breaker is tripped Check the house fuse circuit breaker box and replace the fuse or reset the breaker Power failure If power failure occurs switch off and disconnect unplug the power cord When power is restored reconnect plug in the power cord switch on the power and wait 3 minutes to restart the air conditioner to prevent tripping of the compres...

Page 17: ...MODEL Btu h BODY DIMENSION mm W X H X D WIRING SIZE mm 2 5000 6000 445X320X400 7000 9000 450X350X540 520X340X560 10000 12000 15000 16000 18000 28000 560X400X650 660X435X640 660X430X770 3 1 0 3 1 0 3 1 0 3 1 5 3 2 5 16 ...

Page 18: ...CS267 U ...

Reviews: