Item
Specification
Comments
Switch cascading
Maximum: 5 switches or fewer
Minimum number of cascading
switches is recommended.
MAC address
Per port (fixed value)
Factory setting: World Wide
Unique value. Cannot be
changed.
Maximum transfer unit (MTU)
1,500, 4,500, 9,000 bytes
(Ethernet frame)
Jumbo frame, MTU size greater
than 1500
Link aggregation
Not supported
N/A
Tagged VLAN
Supported
N/A
IPv4
Supported
N/A
IPv6
Supported
Note the following precautions:
•
When iSCSI Port IPv6 is set
to Enabled, if the IPv6
global address is set to
automatic, the address is
determined by acquiring a
prefix from an IPv6 router.
•
If the IPv6 router does not
exist in the network, the
address cannot be
determined. As a result, an
iSCSI connection might be
delayed. When an iSCSI
Port IPv6 is set to Enabled,
verify the IPv6 router is
connected to the same
network, and then set IPv6
global address
automatically.
Subnet mask
Supported
N/A
Gateway address
Supported
N/A
DHCP
N/A
N/A
DNS
N/A
N/A
Ping (ICMP ECHO) Transmit,
Receive
Supported
N/A
IPsec
2
N/A
N/A
TCP port number
3260
Changeable among 1 to
65,535. Observe the following if
changing values:
•
The setting of the
corresponding host should
also be changed to log in
the new port number.
•
The new port number might
conflict with other network
communication or be
iSCSI standards and specifications
77
Hitachi Virtual Storage Platform F800 Hardware Reference Guide
Summary of Contents for Virtual Storage Platform F800
Page 1: ...Hitachi Virtual Storage Platform F800 Hardware Reference Guide MK 94HM8046 07 July 2017 ...
Page 6: ...6 Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...
Page 38: ...38 Storage system drive trays Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...
Page 44: ...44 Host port expansion chassis Hitachi Virtual Storage Platform F800 Hardware Reference Guide ...