--- 8 ---
8-4. Wiring Diagram
8-5. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength: AC 4,000 V/1 minute, with no abnormalities ........................................... 220 V --- 240 V
AC 2,500 V/1 minute, with no abnormalities ........................................... 110 V --- 127 V
8-6. No-load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
Voltage (V)
Current (A) max.
110 V
1.50
120 V
1.45
220 V
230 V
240 V
0.75
Tab Terminal (Blue)
[6]
Tab Terminal (Brown)
[21]
Pillar Terminal
[17]
Internal Wire (Blue)
[22]
White or blue
Internal Wire (Brown)
[5]
For AUS and Europe
Noise Suppressor
[4]
Black or brown
Slide Switch (1P Screw Type)
[18]
Cord
Stator
[20]
Fig. 3
Stator
[20]