– 74 –
WARNING
[A. Main P.W.B.]
Remove four screws securing the control
P.W.B. to the cooling fins, and remove the
control P.W.B. from the cooling fins.
1
[B. Power P.W.B.]
Open the support latches and raise the
power P.W.B. in the direction of the arrow as
shown in Fig. A.
1
Open the support latches and raise
the main P.W.B. in the direction of
the arrow as shown in Fig. A.
2
<Direction of the main P.W.B. removal>
<Direction of the power P.W.B. removal>
Fig. A
Open these support latches to
remove the power P.W.B.
Open these support latches to
remove the main P.W.B.
PRECAUTIONS FOR SERVICING
Be sure that the power switch is turned off or the power cable is disconnected before servicing.
Removing the P.W.B.s.
System Configuration of Outdoor Unit Electrical Parts
The outdoor unit electrical parts consist of two P.W.B. as shown in the figure.
<Main P.W.B. (M board)>
Contains a rectifier circuit and inverter module, their controlling microcomputer and
microcomputer peripheral control circuits. The board incorporates high and low current sections.
<Power P.W.B. (P board)>
Contains a switching power circuit, noise filter, power factor improvement circuit, etc.
The switching power circuit supplies power to electronic circuits on the main P.W.B. through
CN3.
When replacing any P.W.B., disconnect all the cables (including ground wires).
06K134_RAS_35YH6_061-082_E
2006.11.08, 15:26
74
Summary of Contents for Summit RAC-35YH6
Page 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 35FH6 INDOOR UNIT ...
Page 22: ...RAS 35FH6 CIRCUIT DIAGRAM 20 08A392_05_RAS_35FH6_20 21_A2_E 2008 2 22 18 40 20 ...
Page 25: ... 23 button 25 26 26 27 28 26 RAS 35FH6 08A392_07_RAS_35FH6_23_A3_E 2008 3 7 10 07 23 ...
Page 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 35FH6 ...