Communication Port
The following two ports are assigned for the command control.
TCP #23
TCP #9715
Command Control Settings
Con
fi
gure the following items form a web browser when command control is used.
When the authentication setting is enabled, the following settings are required.
Port Settings
Network Control
Port1 (Port: 23)
Port open
Click the
[Enable]
check box to open
[Network
Control Port1 (Port: 23)]
to use TCP #23.
Default setting is “Enable”.
Authentication
Click the
[Enable]
check box for the
[Authentication]
setting when authentication
is required.
Default setting is “Disable”.
Network Control
Port2 (Port: 9715)
Port open
Click the
[Enable]
check box to open
[Network
Control Port2 (Port: 9715)]
to use TCP
#9715.
Default setting is “Enable”.
Authentication
Click the
[Enable]
check box for the
[Authentication]
setting when authentication
is required.
Default setting is “Enable”.
Security Settings
Network Control
Authentication
Password
Enter the desired authentication password.
This setting will be the same for
[Network
Control Port1 (Port: 23)]
and
[Network
Control Port2 (Port: 9715)]
.
Default setting is blank.
Re-enter
Authentication
Password