Application note: Connecting prompter power
Summary:
The prompter power connector is located behind the fiber connector on the Camera Adaptor CA-HF1000.
This is a 5 pin socket with Power interlock.
How to connect:
Parts: 5 pin plug RM12BPE-5PH
Hitachi code JMR0222
Refer to Page 74 of the Operation manual for pin out details.
Connect as follows:
To switch 230V AC on, connect (direct link) Pin 5 to Pin 3.
*Please ensure all local and national Electrical Safety regulations are complied with when connecting
these power lines.
Notes:
If an over
current fault is detected on the AC Power line, the Protective circuit in the CCU will
shut down power to the Camera Adaptor and Camera head.
Please avoid switching AC control line during live recording due to possible interference to the Video
signal from the camera.
Pin 1
230V AC
To Prompter power input L*
Pin 2
GND AC To Prompter power input N*
Pin 3
GND – Interlock
Pin 4
Tally out – To prompter tally input (open collector)
Pin 5
AC Control
B7