Notes for operators and responsible maintenance personnel

★ 

Please read through this Instruction Manual as well as the separate Instruction 
Manual “Safety (MN1-6105)” and “Cleaning, Disinfection and Sterilization 
(MN1-6117)“ carefully prior to use.

★ 

Keep this Instruction Manual together with the ultrasound diagnostic instru-
ment for any future reference. 

© Hitachi, Ltd.  2015, 2017. All rights reserved.

S3ESL1 Probe

Instruction Manual

Specification

MN1-6111  Rev.4

Summary of Contents for S3ESL1

Page 1: ...the separate Instruction Manual Safety MN1 6105 and Cleaning Disinfection and Sterilization MN1 6117 carefully prior to use Keep this Instruction Manual together with the ultrasound diagnostic instru ment for any future reference Hitachi Ltd 2015 2017 All rights reserved S3ESL1 Probe Instruction Manual Specification MN1 6111 Rev 4 ...

Page 2: ...ii MN1 6111 Rev 4 ...

Page 3: ...s and injuries to the operator or patient Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury to the operator or patient Warning Indicates a potentially hazardous situation which if not avoided could result in death or serious injury to the operator or patient Caution Indicates a potentially hazardous situation which if not avoided may res...

Page 4: ...arts 5 3 Preparations before use 7 3 1 Visual check 7 3 2 Deflection portion operation check 7 3 3 Transducer rotation part operation check 7 3 4 Confirmation of cleaning disinfection and sterilization 7 3 5 Operation check 7 4 Operation 9 4 1 Operation of the bite block 9 4 2 Transducer cover usage precautions 9 4 3 Insertion of Probe 10 4 4 Manipulation of Probe 11 4 5 Manipulation of the deflec...

Page 5: ...X7 Classification based on the degree of protection against electric shock Type BF applied part Classification for protection against ingress of liquids IPX7 Watertight equipment Operation mode Continuous operation Method of sterilization Refer to the separate instruction manual Cleaning Disinfection and Sterilization 1 3 Standard components The standard components of S3ESL1 probe are as follows S...

Page 6: ... 2 MN1 6111 Rev 4 ...

Page 7: ...0 relative to insertion direction of insertion portion Range of deflection Up 90 down 60 Insertion portion diameter φ9 Insertion portion length 1017mm Frequency 5 0 MHz 20 Cable length 2100mm weight 900g Service life 3 years Applied part See Figure 1 Part treated as Applied part See Figure 1 IPX7 range See Figure 1 In case that not putting the waterproof case to the ultrasound probe connector In c...

Page 8: ...As shown in the figure below 40 33 50 Unit mm Remarks The tolerance for the dimensions is 10 Figure 3 External view of the bite block 2 3 Transducer cover Use by covering the transducer cover over the insertion portion Transducer cover CIVCO Transducer cover 610 933 Remarks The transducer cover is not included this probe kit ...

Page 9: ...tion for each part is listed in Table 2 Ring Cable Ultrasonic radiation area mark Insertion portion Proximal head Bite block Deflection portion Connector Lock lever Probe tip Angle knob for TD rotation Angle knob for U D defrection Ultrasonic radiation part Figure 4 Name of each parts Insertion part ...

Page 10: ...ent Ring This part is used for hanging the proximal head Bite block This is put in patient s mouth so that keep the path of the probe inserted into the body Caution Do not pull bend twist or apply excessive force to the cable The probe may malfunction due to cable disconnection Do not subject the ultrasonic radiation part to hard impact The impact may cause damage to the transducer and that result...

Page 11: ... no abnormalities in the curvature holding or releasing functions 3 3 Transducer rotation part operation check Turn the angle knob in each direction of the transducer as far as it will go and confirm the following Make sure the transducer rotates smoothly in all directions 3 4 Confirmation of cleaning disinfection and sterilization Confirm that the probe is certainly cleaned disinfected and steril...

Page 12: ... 8 MN1 6111 Rev 4 ...

Page 13: ... Check that the transducer cover is sterilized Use of an infected item could spread infection to the patient Inside of transducer cover use the sterilized ultrasound gel which is attached transducer cover If use echo jerry which not reccomended by instruction manual it is cause to deterioration probe surface Do not reuse the transducer cover Use of an infected item could spread infection to the pa...

Page 14: ...acemaker and an electric apparatus for the medicine such as defibrillators are put on Please use the probe more than 15cm apart from pacemakers Do not close the probe to powerful magnetic field and magnet It may affect to angle indication function Do not close the probe to other electronic equipments It may affect to electronic equipments function Do not submerge or immerse of Proximal head and Co...

Page 15: ...but rather preferably under x ray monitoring to check the state of the probe carefully push the probe until its tip comes into the stomach and straighten the bend by operating the angle knob before pulling back the probe Forcing it to move can injure the patient Occuring J turn The probe gets bent in the esophageal Push the probe until stomach and straighten Keep the angle knob in the free positio...

Page 16: ... time it can reduce the performance or cause smoke or fire If anything unusual occurs immediately stop using it and contact one of our offices and or distributor s offices listed on the back cover Use move and transport the equipment under the environmental conditions specified in this manual Otherwise it may be damaged Do not use with a defibrillator This should result in the probe damaged If you...

Page 17: ...tion represented by an arrow to bend the deflection portion in opposite side of the ultrasound irradiation area Figure 7 4 6 Manipulation of the transducer rotation LEFT Turn the angle knob for TD rotation to L direction represented by an arrow to rotate the transducer clockwise RIGHT Turn the angle knob for TD rotation to R direction represented by an arrow to rotate the transducer counterclockwi...

Page 18: ...please do cleaning and sterilization If reuse without sterilizing there might be the infection to the patient 4 9 Removal of transducer cover Transducer cover wrapped in tissue paper and removed from the probe Dispose of used tissue paper and transducer cover using infection prevention procedures based on the rules of your facility Caution Before disposing of the equipment disinfect or take other ...

Page 19: ... 15 MN1 6111 Rev 4 ...

Page 20: ...chi Ltd 2 16 1 Higashi Ueno Taito ku Tokyo 110 0015 Japan Contact 81 3 6284 3668 http www hitachi com businesses healthcare index html Overseas Offices Hitachi Medical Systems GmbH Otto von Guericke Ring 3 D 65205 Wiesbaden Germany EU Importer Hitachi Medical Systems Europe Holding AG Address Sumpfstrasse 13 CH 6300 Zug Switzerland MN1 6111 Rev 4 17 12 18 ...