1
NAME OF PARTS
1
1.
NAME OF PARTS
RPK-1.0/1.5 FSN1M
No. Part Name
1
AutoSwing louver
2
Air Inlet
3
Front Grill
4
Air Filter
5
Receiver Part
6
Air Outlet
7
Remote Control Switch (Optional)
2.
UNITS INSTALLATION
WARNING:
-
Check to ensure that the accessories are packed with
the indoor unit.
-
Do not install the indoor units outdoors. If installed
outdoors, an electric hazard or electric leakage will
occur.
-
Consider the air distribution from each indoor unit to
the space of the room, and select a suitable location
so that uniform air temperature in the room can be
obtained.
-
The installation height of indoor unit must be 2.3 m or
more.
Pay attention to the following points when the indoor
units are installed in a hospital or other places where
there are electronic waves from medical equipment, etc:
-
Do not install the indoor units where electromagnetic
wave is directly radiated to the electrical box, remote
control cable or remote control switch.
-
Prepare a steel box and install the remote control
switch in it. Prepare a steel conduit tube and wire the
remote control cable in it. Then connect the ground
wire with the box and tube.
-
Install a noise filter when the power supply emits
harmful noises.
-
This unit is exclusive non electrical heater type indoor
unit. It is prohibited to install a electrical heater in the
field.
-
Do not put any foreign material into the indoor unit and
check to ensure that none exist in the indoor unit
before the installation and test running. Otherwise a
fire or failure, etc., may occur.
CAUTION:
-
Do not install the indoor units in a flammable
environment to avoid a fire or an explosion.
-
Check to ensure that the ceiling slab is strong enough.
If not strong enough, the indoor unit may fall down on
you.
-
Do not install the indoor units, outdoor unit, remote
control switch and cable within approximately 3
meters of strong electromagnetic wave radiators such
as medical equipment.
-
Do not install the indoor units in a machinery shop or
kitchen where vapor from oil or mist flows to the
indoor units. The oil will deposit on the heat
exchanger, thereby reducing the indoor unit
performance, and may deform. In the worst case, the
oil damages the plastic parts of the indoor unit.
-
To avoid any corrosive action to the heat exchangers,
do not install the indoor units in an acid or alkaline
environment.
-
When lifting or moving the indoor unit, use appropriate
slings to avoid damage and be careful not to damage
the insulation material on units surface.