4.3 Installation
The dimensions of the mounting bracket and the
unit installation are indicated in Fig. 4.3.
4.3.1 Mounting Bracket onto Wall
When the mounting bracket is directly attached
to a wood wall or a concrete wall, check to ensure
of 2000N.
Attach the mounting bracket to the concrete wall
with anchor bolts as shown in Fig. 4.4
Mounting Bracket
Fig. 4.4 Mounting on Concrete Wall
4.3.2 Mounting the Indoor Units
Hook the indoor unit to the mounting bracket,
maintaining the indoor unit upright.
Fig 4.5 Mounting of the Indoor Units
Check to ensure that the unit is completely
hooked onto the mounting bracket.If not,it
may drop from the bracket, resulting in a
serious accident.
4.3.3 Removing Front Panel
In order to connect the refrigerant piping,
wiring and to check drain water flow, removing
the front panel is needed. Perform these work
according to the following instructions. Pay
attention to the resin components not to scratch.
(1) Hold both sides of the flat panel and open it,
and pull the right arm toward the inner side.
Slightly close the flat panel and pull it, then
remove the flat panel.
Flat Panel
(2) Remove the air filter and two (2) screws.
Slowly pull the lower side ofthe front panel and
release the catch by paying attention to the air
outlet part without touching the outlet grille.
(3) Pay attention to the junction of grille
from each side, to prevent breaking off.
Summary of Contents for RPK-0.8FSNQS
Page 2: ...32DB 23WB HITACHI HITACHI HITACHI ...
Page 5: ...3 17 13 14 14 15 15 16 16 Common 18 the Filter Indication Interval ...
Page 9: ...7 8 4 8 1 ...
Page 10: ...9 9 1 9 2 9 3 9 4 5 8 2 8 3 approximately ...
Page 24: ...Qingdao Hisense Hitachi Air Conditioning Systems Co LTD P00611Q 2013 10 V00 ...