– 76 –
INSPECTING OUTDOOR ELECTRICAL PARTS
LED number
Name
Diagnosis
lamp 1
Diagnosis
lamp 2
Communications
lamp
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Case 1
Case 2
Blinks once
Blinks
Blinks
On
On
On
On
On
On
On
On
Normal operation
Thermistor abnormally
Abnormally stop
Normal off status or
unconnected
microcomputer power
source
Microcomputer reset
status (immediately
after inserting power
source or immediately
after power source
abnormally)
OVL1 operation
OVL2 operation
OVL3 operation
Normal operation
Normal operation
Normal operation
Normal operation
On
Case 3
Case 4
Case 5
Case 6
Case 7
Case 8
LD301
LD302
LD303
Status
Checkpoints
If the LED is not on even when the
power source is connected the
microcomputer power source is
unconnected.
Inspection method 1
Abnormally stop is shown by the
number of times the LED blinks.
Inspection method 2
Thermistor abnormally is shown by
the number of times the LED blinks.
Inspection method 3
If is normal for LD301 to blink once
after the power source has been
inserted. If the unit stops when it is in
operation and LD301 blinks once, it is
possible that the power source has
been temporarily interrupted by
lightning or for some other reason.
Replace the control PCB if this occurs
frequently.
Check to see that the LED is either on or blinking.
Carry out inspections by examining the on/blinking status of LEDs 301-303.
Carry out inspections by examining the on/blinking status of LEDs 304-308.
LED NO.
Communication
Lamp
Communication
Lamp
Communication
Lamp
Communication
Lamp
Communication
Lamp
LD304
LD308
LD307
LD306
LD305
Status
Checkpoint
Inspection methody 4
Name
Case 9
Off
On
On
On
On
Communication
error
Check the connection of
indoor unit 1 (C1, D1)
Case 10
On
Off
On
On
On
Communication
error
Check the connection of
indoor unit 2 (C2, D2)
Case 11
On
On
Off
On
On
Communication
error
Check the connection of
indoor unit 3 (C3, D3)
Case 12
On
On
On
Off
On
Communication
error
Check the connection of
indoor unit 4 (C4, D4)
Case 13
On
On
On
On
Off
Communication
error
Check the connection of
indoor unit 5 (C5, D5)
➞
Summary of Contents for RAM-90QH5
Page 13: ... 12 ...
Page 14: ... 13 ...
Page 15: ... 14 ...
Page 19: ... 18 BASE DRAIN PIPE A DRAIN PIPE BUSH 100 mm ABOVE 10 11 ...
Page 21: ... 20 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAM 90QH5 Service space ...
Page 26: ...CIRCUIT DIAGRAM MODEL RAM 90QH5 27 ...
Page 28: ... 31 ...
Page 31: ... 37 ...
Page 32: ... 39 ...
Page 33: ... 41 ...
Page 34: ... 43 ...
Page 36: ... 45 90 23 ...
Page 42: ... 51 REFRIGERATING CYCLE DIAGRAM MODEL RAM 90QH5 ...
Page 51: ... 60 3 System power Module Circuit ...
Page 60: ... 69 Electric expansion valve thermistor NARROW PIPE 5 5 5 5 8 8 8 ...
Page 72: ... 85 ...
Page 76: ... 90 Lighting mode self diagnosis lamp Location of self diagnosis lamp 1 RAM 90QH5 ...
Page 77: ... 91 Lighting mode self diagnosis lamp 2 RAM 90QH5 ...
Page 83: ...HITACHI PM NO 0371E Printed in Malaysia RAM 90QH5 ...