![Hitachi RAM-18QH5E Service Manual Download Page 2](http://html.mh-extra.com/html/hitachi/ram-18qh5e/ram-18qh5e_service-manual_2139476002.webp)
– 1 –
SAFETY DURING REPAIR WORK
1. In order to disassemble and repair
the unit in question, be sure to
disconnect the power cord plug
from the power outlet before starting
the work.
2. If it is necessary to replace any parts, they should be replaced with respective genuine parts for the unit, and
the replacement must be effected in correct manner according to the instructions in the Service Manual of
the unit.
If the contacts of electrical parts
are defective, replace the
electrical parts without trying to
repair them.
3. After completion of repairs, the initial state
should be restored.
4. Lead wires should be connected and laid as
in the initial state.
5. Modification of the unit by user himself should
absolutely be prohibited.
6. Tools and measuring instruments for use in repairs or inspection should be accurately calibrated in advance.
7. In installing the unit having been repaired, be careful to prevent the occurence of any accident such as
electrical shock, leak of current, or bodily injury due to the drop of any part.
8. To check the insulation of the unit, measure the insulation resistance between the power cord plug and
grounding terminal of the unit. The insulation resistance should be 1M or more as measured by a 500V
DC megger.
9. The initial location of installation such as window, floor or the other should be checked for being and safe
enough to support the repaired unit again.
If it is found not so strong and safe, the unit should be installed at the initial location reinforced or at a new
location.
10. Any inflammable thing should never
be placed about the location of
installation.
11. Check the grounding to see whether
it is proper or not, and if it is found
improper, connect the grounding
terminal to the earth.
DANGER
First, I must disconnect
the power cord plug
from the power outlet.
Summary of Contents for RAM-18QH5E
Page 9: ... 8 ...
Page 10: ... 9 RAM 18QH5E MODEL RAM 18QH5E ...
Page 11: ... 10 ...
Page 12: ... 11 AC 220V 240V ONLY L N INDOOR 1 C1 D1 C2 D2 INDOOR 2 RAM 18QH5E ...
Page 13: ... 12 RAM 18QH5E ...
Page 21: ... 20 MODEL RAM 18QH5E WIRING DIAGRAM OUTDOOR UNIT ...
Page 23: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAM 18QH5E 23 MOUNTING PCB SET TYPE ...
Page 25: ... 27 heating ff BASIC MODE MODEL RAM 18QH5E ...
Page 28: ... 33 Table 6 Table 7 ...
Page 29: ... 35 ...
Page 31: ... 37 ...
Page 56: ... 62 Fig 11 2 ...
Page 69: ... 75 1 Outdoor unit does not operate remote control signal can be received RAM 40QH5 ...
Page 71: ... 77 Lighting mode self diagnosis lamp 2 RAM 18QH5E ...
Page 72: ... 78 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 73: ... 79 ...
Page 74: ... 80 ...
Page 75: ... 81 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 18QH5E ...