10-
9
Example of wiring connection to Card Key Unit will be as below (reference only)
CARD KEY UNIT (Prepared by INSTALLER)
AIR CONDITIONER INDOOR PCB
•
CONNECTION EXAMPLE
i. Pin No. 3 of DIP SWITCH is set to OFF position (HI Input Active) for Dry Contact Type a
ii. Pin No. 3 of DIP SWITCH is set to ON position (LO Input Active) for Dry Contact Type b
Please refer to the actual manual supplied with the optional connecting cords SPX-WDC3 for more details.
AC
POWER
SUPPLY
①
Connecting Cord to PCB:
SPX-WDC3
②
Contact with sleeve
CN6
DIP SW (DSW1)
Dry contact
Card sensor
indicator
Window
Close: ON
Open: OFF
Window
Close: ON
Open: OFF
Card key unit
Insert Card: ON
Remove Card: OFF
Indoor unit
PWB
Connection
Connection
SERIAL CONNECTION
All SW
ON
→
OPERATION
Connecting cord to PCB
Accessory# SPX-WDC3
Window
Close: OFF
Open: ON
Window
Close: OFF
Open: ON
Card key unit
Insert Card: OFF
Remove Card: ON
Indoor unit
PWB
PARALLEL CONNECTION
All SW
OFF
→
OPERATION
Connecting cord to PCB
Accessory# SPX-WDC3
Connection
Connection