11. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations]
䊶
Erroneous connection in the indoor-outdoor connection line (F cable)
䊶
Wire break or poor insertion of the indoor-outdoor connection line (F cable)
䊶
Electrical parts in the outdoor unit (communication circuit, power circuit error)
䊶
Communication error due to noise in other home electronics
㶎
This does not constitute a failure in the air-conditioner
[Cautions]
䊶
When lines 1 and 2 of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times", then, just in case, check if the F cable is not erroneously connected.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Yes
Yes
Yes
Yes
No
No
No
No
Correct the F cable connection.
Is the CN securely inserted into
the outdoor board?
Correct the connector.
Press the START/STOP button on the remote control
unit and start the product.
Are terminals 1 and 2of the terminal board of the
electrical parts of the outdoor unit subjected to
㶎
Take measurements within 3 minutes after remote
control operation.
Check the electrical parts of the
outdoor unit.
Are terminals 1 and 2 of the terminal board of the electrical
parts of the indoor unit subjected to
220-230V ?
㶎
Take measurements within 3 minutes after remote control
operation.
Double-check the F cable for erroneous connection,
wire break and poor insertion, and correct the
nonconforming parts.
Replace the "indoor control P.W.B".
1 . Timer lamp blinking: blinking 13 times
[Situation] The timer lamp blinks 13 times and the product will not run.
[Estimated failure location]
䊶
EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor control P.W.B".
2
䊶
Forget to connect CN27 of outdoor P.W.B
AC 220-230V ?
AC
27
79
Summary of Contents for RAK-15QEF
Page 2: ... DANGER 2 ...
Page 21: ...WIRING DIAGRAM MODEL RAK 15QEF RAK 18 25 35 50REF RAK 18 25 35 50REFC 21 ...
Page 22: ...WIRING DIAGRAM OF THE PRINTED WIRING BOARD Remote controller RAR 7PE1 22 ...
Page 23: ...CIRCUIT DIAGRAM MODEL RAK 15QPE RAK 18 25 35 50REF RAK 25 35 50REFC AX 17H725 ...
Page 25: ...31 33 29 MODEL RAK 15QPE RAK 18 25 35 50REF RAK 25 35 50REFC 25 ...
Page 38: ...MODEL RAK 15QEF RAK 18 25 35REF RAK 25 35REFC 38 ...
Page 39: ...MODEL RAK 50REF RAK 50REFC 39 ...
Page 42: ...DESCRIPTION OF MAIN CIRCUIT OPERATION MODEL RAK 15QEF RAK 18 25 35 50REF RAK 25 35 50REFC 42 ...
Page 48: ...10 10 10 10 10 DSW1 48 ...
Page 52: ...RL1 RL1 RL2 52 ...
Page 64: ...ON OFF ON OFF ON OFF 3 and page 3 8 9 64 ...
Page 65: ...DISPLAY OPERATION MODE SETTING ON OFF 65 ...
Page 66: ... FAN SPEED POWERFUL FAN SPEED POWERFUL HOW TO CHANGE THE INTERMITTENT FAN CONTROL SETTING 66 ...