1.
In quiet or stop operation, slight flowing noise of refrigerant in the refrigerating cycle is heard occasionally,
but this noise is not abnormal for the operation.
2.
When it thunders near by, it is recommend to stop the operation and turn off the circuit break er for safety.
3.
In the event of power failure,the room air conditioner will restare automatically in the previously
mode once the power is restored. In the event of power failure during TIMER operation, the room air comditioner
will not start automatically. Re-press ON/OFF button after 3 minutes from when the unit off or power recovery.
4.
If the room air conditioner is stopped by adjusting thermostat, or missoperation, and re-start in a moment,
there is occasion that the cooling and heating operation does not start for 3 minutes, it is not abnormal and
this is the result of the operation of IC delay circuit. This IC delay circuit ensures that there is no danger of
blowing fuse or damaging parts even if operation is restarted accidentally.
5.
This room air conditioner should not be used at the cooling operation when the outside temperature is
below -10°C (14°F).
6.
This room air conditioner (the reverse cycle) should not be used when the outside temperature is below
–15°C (5°F).
If the reverse cycle is used under this condition, the outside heat exchanger is frosted and efficiency falls.
7.
When the outside heat exchanger is frosted, the frost is melted by operating the hot gas system, it is not
trouble that at this time fan stops and the vapour may rise from the outside heat exchanger.
!
CAUTION
selected
5
Summary of Contents for RAK-15QEF
Page 2: ... DANGER 2 ...
Page 21: ...WIRING DIAGRAM MODEL RAK 15QEF RAK 18 25 35 50REF RAK 18 25 35 50REFC 21 ...
Page 22: ...WIRING DIAGRAM OF THE PRINTED WIRING BOARD Remote controller RAR 7PE1 22 ...
Page 23: ...CIRCUIT DIAGRAM MODEL RAK 15QPE RAK 18 25 35 50REF RAK 25 35 50REFC AX 17H725 ...
Page 25: ...31 33 29 MODEL RAK 15QPE RAK 18 25 35 50REF RAK 25 35 50REFC 25 ...
Page 38: ...MODEL RAK 15QEF RAK 18 25 35REF RAK 25 35REFC 38 ...
Page 39: ...MODEL RAK 50REF RAK 50REFC 39 ...
Page 42: ...DESCRIPTION OF MAIN CIRCUIT OPERATION MODEL RAK 15QEF RAK 18 25 35 50REF RAK 25 35 50REFC 42 ...
Page 48: ...10 10 10 10 10 DSW1 48 ...
Page 52: ...RL1 RL1 RL2 52 ...
Page 64: ...ON OFF ON OFF ON OFF 3 and page 3 8 9 64 ...
Page 65: ...DISPLAY OPERATION MODE SETTING ON OFF 65 ...
Page 66: ... FAN SPEED POWERFUL FAN SPEED POWERFUL HOW TO CHANGE THE INTERMITTENT FAN CONTROL SETTING 66 ...