Removal Of Air From The Pipe And Gas Leakage Inspection

Gas Leakage Inspection

Please use gas leakage detector 
to check if leakage occurs at the 
connection of Flare nut as shown 
on the right.

If gas leakage occurs, further tighten 
the connection to stop leakage. (Use 
the detector provided for R410A)

FINAL

 ST

AGE OF INST

ALLA

TION

Insulation And Maintenance Of Pipe Connection

1

 The connected terminals should be completed sealed with 

heat insulator and then tied up with rubber strap.

 Please tie the pipe and power line together with vinyl tape 

as shown in the  gure showing the installation of Indoor and 
Outdoor units. Then  x their position with holders.

 To enchance the heat insulation and to prevent water 

condensation, please cover the outdoor part of the drain hose 
and pipe with insulation pipe.

 If room humidity is high, cover the connecting pipe with 

additional 5mm thickness insulator. This insulator shall be 
purchased from  eld.

 Completely seal any gap with putty.

  Installation Of Remote Controller

2

  Power Source And Operation Test

3

 The remote controller can be placed in its holder which is 

 xed on wall or beam.

 To operate the remote controller at its holder, please ensure 

that the unit can receive signal transmitted from the controller 
at the place where the holder is to be  xed. The unit will beep 
when signal is received from the remote controller. The signal 
transmission is weaken by the  orescent light. Therefore, 
during the installation of the remote control holder, please 
switch on the light, even during day time, to determine the 
mounting location of the holder.

Power Source

CAUTION

!

 Please make sure, that the power voltage is 220V-240V 

within the operation voltage of the unit.

 Please take under consideration, that the power capacity 

from your house distribution box is high enough for operating 
your room air conditioner.

Operation Test

  Please ensure that the air conditioner is in normal operating 

condition during the operation test.

 Explain to your customer the proper operation procedures 

as described in the user’s manual.

3

Procedures of using Vacuum Pump for Air Removal

   Preparation of Pipe

1

 Use a pipe cutter to cut the copper pipe.

 Jagged edge will cause leakage.

 Point the side to be trimmed downwards during trimming to 

prevent copper chips from entering the pipe.

 Before  aring, please insert the  are nut into the pipe.

   Pipe Connection

2

INST

ALLA

TION OF REFRIGERA

TING PIPES 

AND 

AIR REMOV

AL

CAUTION

!

AIR REMOV

AL

 THIS APPLIANCE MUST BE EARTHED.

Wiring Of The Indoor Unit

(1)  Remove the cover of the electric box.
(2)  Connect the connecting cords.
(3)  Assemble the cover of electric box.

Procedures of Wiring

CONNECTION OF POWER CORD

CAUTION

!

In case of removing Flare nut of a indoor unit,  rst remove a nut of small diameter side, or a 
seal cap of big diameter side will  y out.

 Please be careful when bending the copper pipe.

 Applied frozen grease to the connection points and then screw in 

manually. After that, use a torque wrench to tighten the connection.

WARNING

!

Power supply shall be connected at the rated voltage, otherwise the unit will be 
broken or could not reach the speci ed capacity.

  Installation Of Optional Panel

4

  Carefully read through the procedures of proper installation 

before starting installation work.

<

IA992: A 

>

Checking for the electric 
source and the voltage range

 B e f o r e   i n s t a l l a t i o n ,   t h e   p o w e r   s o u r c e   m u s t   b e

  c h e c k e d   a n d   n e c e s s a r y   w i r i n g   w o r k   m u s t   b e
  completed. To make the wiring capacity proper,
  use the wire gauge list below for the wiring from a
  switch board of fuse box to the outdoor unit in
  consideration of the locked rotor current.

IMPORTANT

Fuse Capacity

16A time delay fuse

IMPORTANT

Cable length

up to 

1

6m

up to 15m

up to 25m

Wire cross-section

1.5mm

2

2.5mm

2

4.0mm

2

 The naked part of the wire core should be 10 mm and  x it to the terminal 

tightly. Then try to pull the individual wire to check if the contact is tight. 
Improper insertion may burn the terminal.

 Be sure to use only power cables approved from the authorities in your 

country. For example in Germany: Cable type: NYM 3x1.5mm2.

 Please refer to the installation manual for wire connection to the terminals 

of the units. The cabling must meet the standards of electrical installation.

  There is a AC voltage of 220-240V between the L and N terminals. Therefore, 

before servicing, be sure to remove the plug from the AC outlet or switch 
off the main switch.

WARNING

!

When the meter reaches - 101KPa 
(-76cmHg) during pumping, fully 
tighten the shuttle.

Meter showing pressure

R410A
Manifold valve

Vacuum 
pump

Valve

Charge hose

Valve

Vacuum 
pump
adapter

When pumping starts, slightly loosen the 
 are nut to check of air sucked in. Then 
tighten the  are nut.

[For all optional part, please refer catalog for part number]

As for connecting to H-Link, a separately purchased RAC Adapter is
required.

 To install the wiring the electrical box cover must be opened.

 Connect the connector of RAC adapter to CN1101.

 Assemble back the cover of electrical box.

 Please refer to the respective user manual of RAC Adapter for further details.

 Please be careful not to damage lead wires by edge of plate when connecting the 

optional parts.

[For all optional part, please refer catalog for part number]

Connection to the electrical box:

 Remove the cover of electrical box.

 Connect the connector of wired remote controller to CN1102.

 Assemble back the cover of electrical box.

 Please refer to the respective user manual of wired remote controller for further 

details.

 Please be careful not to damage lead wires by edge of plate when connecting the 

optional parts.

WIRED REMOTE CONTROLLER

H-LINK

How To Connect The Optional Parts

(RAC Adapter, Wired Remote Controller)

CN1101

CN1102

RAC Adaptor cord

Wired remote controller cord

Outer
Diameter 
mm (inch)

6.35 (1/4")

9.52 (3/8")

12.70 (1/2")

15.88 (5/8")

1.0 ~ 1.5

1.0 ~ 1.5

1.0 ~ 1.5

1.0 ~ 1.5

Clutch type

A (mm)

1.5 ~ 2.0

1.5 ~ 2.0

1.5 ~ 2.5

1.5 ~ 2.5

Wing nut type

Thickness

(mm)

0.8

0.8

0.8

1.0

0.0 

~

 0.5

0.0 

~

 0.5

0.0 

~

 0.5

0.0 

~

 0.5

Flare tool for R410A

Clutch type

Conventional  are  tool

Outer

dia.of pipe

6.35 (1/4")

9.52 (3/8")

12.70 (1/2")
15.88 (5/8")

6.35 (1/4")

9.52 (3/8")
12.7 (1/2")

Valve 

head cap

Torque N·m

(kgf 

·

 cm)

14.0 – 18.0 (140 – 180)

33.0 – 42.0 (330 – 420)
50.0 – 62.0 (500 – 620)
63.0 – 77.0 (630 – 770)

19.6 – 24.5 (200 ~ 250)

19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 – 350)

12.3 – 15.7 (125 ~ 160)

Small dia. side

Large dia. side

Valve core cap

Small dia. side

Large dia. side

As shown in right  gure, remove the cap of valve core. Then, 
connect the charge hose. Remove the cap of valve head. Connect 
the vacuum pump adapter to the vacuum pump and connect the 
charge hose to the adapter.

Fully tighten the “Hi” knob of the manifold valve and completely 
unscrew the “Lo” knob. Run the vacuum pump for about 10~15 
minutes, then completely tighten the “Lo” knob and switch off the 
vacuum pump.

2

Completely unscrew the spindle of the service valve (at 2 places) 
in anti-clockwise direction to allow the  ow of refrigerant (using 
Hexagonal Wrench key).

Re-cap the service valve and tighten using wrench. Check the cap’s 
periphery if there is any gas leakage. The task is then completed.

Remove the charge hose and tighten the cap of valve core. Check 
the cap’s periphery if there is any gas leakage. 

4

5

1

3

The remote controller 
must be slide in
the remote controller 
holder, in the direction 
as shown in the  gure, 
until it hooks at the 
lower end of the remote 
controller holder.

Screw (2 pieces)

Remote 
Controller 
Holder

Remote
Controller

INS RAI-25-35-50RPA (EN2)   1