Insulation and Maintenance of Pipe
1
FINAL ST
A
GE OF INST
ALLA
TION
Earth Line And Circuit Breaker
3
FINAL TREA
TMENT
Method to Remove Electrical Cover
●
Remove the screw and electrical cover.
●
Insert the connecting cord (A, B) and thermistor wire from the bottom of unit.
●
Fixed the wire to terminal wires firmly as shown in figure below.
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove front panel and electrical cover.
Electrical Cover
Fixing Screw
WARNING
●
You may not be able to close the side cover due to the connecting cord, under such situation,
please press against the wait of side cover to fix it.
●
Be sure that the hooks (2 places) are plugged in.
Otherwise, water leakage may occur and this causes short circuit or faults.
Wiring Of The Outdoor Unit
●
Please remove the side cover for wire connection.
!
E
A
B
Pipe
Connecting Cord And
Thermistor Wire
Bottom Cover
Thermistor Wire
Fixing Band
Connecting Cord And
Thermistor Wire
B
A
Side Cover
Connection Wire Is
Put Under Here
Connection Wire And
Thermistor Wire
Power Source And Operation Test
4
Power Source
CAUTION
!
●
Please use a new socket. Accident may occur due to the use of old socket because of poor contact.
●
Please plug in and then remove the plug for 2 – 3 times. This is to ensure that the plug is completely plugged
into the socket.
●
Keep additional length for the power cord and do not render the plug under external force as this may cause
poor contact.
●
Do not fix the power cord with U-shape nail.
Operation Test
●
Please ensure that the air conditioner is in normal operating condition during the operation test.
●
Explain to your customer the proper operation procedures as described in the user’s manual.
CAUTION
!
●
The earth line terminal of the outdoor unit is below the service valve.
●
To avoid short circuit, it is necessary to install circuit breaker depending on the mounting location of the unit.
●
Do not place earth line near the following objects:
(1)
Water pipe
(2)
Gas pipe – There is danger of catching fire.
(3)
The earth line of lightning conductor and telephone – short circuit may occur during lightning.
WARNING
!
●
Do not alter the plug of power cord.
●
Do not make extension to the power cord.
●
The connected terminals should be completely sealed with heat insulator and then tied up with rubber strap.
●
Please tie the pipe and power line together with plastic tape as shown in the figure of installation of both the
indoor and outdoor units. Then fix their position with holders.
●
To enchance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain
hose and pipe with insulation pipe.
●
Completely seal any gap with putty.
Insulation Material For Pipe Connection
Sleeve Of
Protection
Pipe
Installation Of Remote Control
2
●
The remote controller can be placed in its holder which is fixed on wall or beam.
●
To operate the remote controller at its holder, please ensure that the unit can receive signal transmitted from
the controller at the place where the holder is to be fixed. The unit will beep when signal is received from the
remote controller. The signal transmission is weaken by the florescent light. Therefore, during the installation
of the remote control holder, please switch on the light, even during day time, to determine the mounting
location of the holder.
Wall Of Pilar
Remote Control Mounting Screw
Air Exchanger’s End Treatment
1
●
When not using protection cap.
(1) Make sure the air exchanger hose and end of rain ventilate nets gap is 230~280mm from wall.
• If air exchanger hose directly bend downward from hole, make sure the cutting is 250~280mm from wall.
• If air exchanger hose directly connect to outdoor, cut 250~280mm from the bend point.
(2) Seal the anti insect ventilate net and rain proof ventilate net which suits with air exchanger hose by using
vinyl 1 tape.
(3) Fix drain hose with tape. Make sure the exit is facing downward.
CAUTION
!
●
If gap until end of air exchanger is too small and air exchanger end is not fix downward, there is possibility
that the rain is enter to rain.
●
At strong wind area and side area, set is longer.
(1) Air Exchange Hose
(3) Anti Insect Ventilate
Net’s Hook Must Be
Fixed With Rain Proof
Ventilate Net.
(2) Press Rain Proof Ventilate Net.
(4) Seal With Vinyl Tape
Air
Exchange
Hose
Coolant
Pipe
Cap
Net
To Fix Ventilate Pipe Through Wall
2
●
In case hole can be opened from outside wall.
(1) Diameter hole is ø40.
(2) Air exchanger hose put outside, fix anti-insect ventilate net and rain proof ventilate net with vinyl tape.
(3) Fix the air exchanger facing downward with fixing plate.
Seal With Sealer
Connecting Cord
Refrigerating Pipe
Drain Hose
Seal With Sealer
At Exchange Hose
Fixing Plate (option)
Air Exchange Hose
Ventilate Pipe
Facing Down
Do Not Cut The Hose
Putty
IMPORTANT
Fuse Capacity
10A time delay fuse