![Hitachi RAC-E14H2 Service Manual Download Page 47](http://html.mh-extra.com/html/hitachi/rac-e14h2/rac-e14h2_service-manual_139795047.webp)
– 45 –
Ip (peak current cut)
LD301
Blinks 2
times
Blinks 3
times
Blinks 4
times
LD301
LD301
Self-diagnosis
Self-diagnosis lamp
and mode
Abnormal low speed
rotation
Switching incomplete
Fig. 4-5
Table 4-1
Fig. 4-4 Power module circuit (U
+
is OFF, V
–
is ON)
Since current flows at point
B
only when U+ transistor and V- transistor are ON, the current waveform
at point
B
becomes intermittent waveform as shown in Fig. 4-3. Since current at point
B
is approximately
proportional to the input current of the air conditioner, input current is controlled by using DC current
(Id) detection resistor.
<Reference>