![Hitachi RAC-E14H2 Service Manual Download Page 37](http://html.mh-extra.com/html/hitachi/rac-e14h2/rac-e14h2_service-manual_139795037.webp)
– 35 –
IPM
POWER P.W.B.
N.F. FILTER
ICP CIRCUI
T
SWITCHING
POWER SUPPLY.
REVERSING VALVE
CONTROL CIRCUIT
ELECTRIC EXPANSION VALVE
CONTROL CIRCUIT
INTERFACE
CIRCUIT
A
B
C
D
MAIN P.W.B.
RECTIFIER
INVERTER
CONTROLCIRCUIT
COMPRESSOR
INVERTER CIRCUIT
SMOOTHING
CAPACITOR
HARMONICS
IMPROVEMENT
CIRCUIT
RESET
CIRCUIT
POSSITON
DETECTIVE
CIRCUIT
MICRO
COMPUTER
FAN MOTOR
CONTROL
CIRCUIT
THERMISTOR
DETECTION
CIRCUIT
Fig. 1-1
MODEL RAC-E14H2
1. The electrical parts for the outdoor unit is composed of two P.W.B. (a power P.W.B. and main P.W.B.)
and a harmonics improvement circuit as shown in Fig. 1-1.
•
Main P.W.B.
This P.W.B. is equipped with the rectification diode, DC fan motor control circuit and the circuits
around the micro computer which take various controls.
•
POWER P.W.B.
This P.W.B. is equipped with the noise filter, ICP power circuit, interface circuit, smoothing capacitor,
expansion valve control circuit and four-way valve control circuit.
•
HARMONICS IMPROVEMENT CIRCUIT
This circuit is composed of the capacitor at the bottom of the electrical parts box and two reactors
attached to the BULKHEAD.