The dust and dirt adhering to indoor heat exchanger is the cause of the smell. They are washed away
by
freezing and thawing of the heat exchanger.
●
●
Indoor
Frost Wash function can work when the outdoor temperature is 1
℃ to
43
℃
and indoor humidity is 30%
to 70%.
There are two kinds of
Indoor
Frost Wash operation, auto mode
and manual mode.
INDOOR
FROST WASH OPERATION
※
It depends on the conditions of the room.
The process of
Indoor
Frost Wash
About 8 min
About 20 min to 90 min.
Operation such as
cooling operation
Freezing and thawing heat exchanger
Auto Stop
Running
Stop
The deflectors remain opened
during
fan operation, freezing, thawing.
●
If you want to stop
Indoor
Frost Wash operation, press the
(
ON/OFF
) button twice.
●
lamp on the indoor unit lights up during
Indoor
Frost Wash operation.
Indoor
Frost Wash
starts
Indoor
Frost Wash
ends
●
When pressing the button such as cooling during
Indoor
Frost Wash operation,
Indoor
Frost Wash operation
is discontinued
and start the cooling operation after about 3 minutes.
●
When
Indoor
Frost Wash is stopped during
Indoor
Frost Wash operation, the unit automatically restart
Indoor
Frost Wash operation
when the next operation stops.
●
In order to protect the
unit
,
Indoor
Frost Wash function cannot be carried out again for about 60 minutes after
Indoor
Frost
Wash operation is completed.
" "
Fan operation
■
Indoor Frost Wash
(Auto mode)
Indoor
Frost Wash auto start conditions
●
When the outdoor temperature or indoor humidity are not suitable for
Indoor
Frost Wash operation, only fan
operation
is carried out,
Indoor
Frost Wash operation will be done again
after the next operation stops.
●
Sometimes the heat exchanger may not freeze depending on the conditions of the room.
●
When the ON timer reaches the set time during
Indoor
Frost Wash operation, it will stop the
Indoor
Frost Wash
operation
and start the operation of setting mode.
●
If the interval of the Off to On timer is less than 2 hours,
Indoor
Frost Wash operation may not be completed. In
that case, it will restart
Indoor
Frost Wash operation
after the next operation stops.
Once the auto mode of
Indoor
Frost Wash operation interval (42 hours) is reached, stop operating the air
conditioner
and activate
Indoor
Frost Wash in Auto or Manual mode.
Accumulated operating hours of the air conditioner have exceeded 42 hours
Air conditioner is
stopped operating for more than 30 minutes,
such as cooling
operation
Indoor
Frost Wash start
Indoor
Frost Wash end
About 20 min to 90 min.
About 30 minutes or more
Operation such as
cooling operation
Operation such as
cooling operation
Last
Indoor
Frost Wash
Running
Stop
Running
Stop
Auto Stop
Indoor
Frost Wash
Accumulated operating hours of the air conditioner
have exceeded 42 hours