ELECTRICAL DATA
15
6
6
ELECTRICAL DATA
6.1.
INDOOR UNIT
Model
Unit Main Power
Applicable Current
Indoor Fan Motor
VOL, PH, Hz
Fuse Rating (A)
STC
RNC
RNC
IPT
RAK-35RPC
230, 1, 50
3.15
(C) 5.13 (H) 5.17
(C) 6.35 (H) 7.39
0.67
30
RAK-50RPC
230, 1, 50
3.15
(C) 7.89 (H) 8.24
(C) 9.13 (H) 11.96
0.67
30
VOL: Rated Unit Power Supply Voltage (V)
RNC:
Running Current (A)
Hz:
Frequency (Hz)
PH:
Phase (
I
)
STC: Starting Current (A)
IPT:
Input (W)
6.2.
OUTDOOR UNIT
Model
Unit Main Power
Compressor Motor
VOL, PH, Hz Fuse Rating (A) Min (V) Max (V) Locked Rotor Ampere (A) STC
Cooling Operation Heating Operation
RNC
IPT
RNC
IPT
RAC-35WPC
230, 1, 50
15
207
253
-
5.17 6.35 1090 7.39 1100
RAC-50WPC
230, 1, 50
25
207
253
-
8.24 9.13 1560 11.96 1660
VOL: Rated Unit Power Supply Voltage (V)
RNC:
Running Current (A)
HZ:
Frequency (Hz)
PH:
Phase (
I
)
STC: Starting Current (A)
IPT:
Input (W)
NOTE:
1. The above compressor data is based on 100% capacity combination of indoor units at the rated operating frequency
2. This data is based on the same conditions as the nominal heating and cooling capacities.
3. The compressor started by an inverter, resulting in extremely low starting current.
Summary of Contents for RAC-35WPC
Page 1: ...TECHNICAL CATALOGUE MONO SPLIT RAC 35WPC RAK 35RPC RAK 50RPC RAC 50WPC ...
Page 18: ...WIRING DIAGRAM 16 7 7 WIRING DIAGRAM 7 1 RAK 35RPC RAK 50RPC ...
Page 19: ...WIRING DIAGRAM 17 7 7 2 RAC 35WPC ...
Page 20: ...WIRING DIAGRAM 18 7 7 3 RAC 50WPC ...
Page 42: ...HITACHI TC ERP Model INDOOR OUTDOOR RAK RAC 50WPC RAC 35WPC 50RPC RAK 35RPC ...