WORKING RANGE
14
5
5
WORKING RANGE
5.1.
POWER SUPPLY
Working Voltage
207V ~ 253V
Voltage Imbalance
Within a 3% Deviation from Each Voltage at the Main Terminal of
Outdoor Unit
Starting Voltage
Higher than 85% of the Rated Voltage
5.2.
WORKING RANGE
Applicable models:
RAC-35WPC
RAC-50WPC
The temperature range is indicated in the following table.
Cooling
Heating
working range
min (
o
max (
C)
o
rated (
C)
o
C)
working range
min (
o
max (
C)
o
rated (
C)
o
outdoor
C)
-10 43 35
outdoor -15 21
7
indoor 16
43 27
indoor 16 26
20
-30
-20
-10
0
10
20
30
40
50
5 10 15 20 25 30 35 40 45 50
Cooling working range
-30
-20
-10
0
10
20
30
40
0
5
10 15 20 25 30 35 40
Heating working range
Indoor Temperature
Indoor Temperature
Ambie
n
t Te
m
p
eratur
e
COOLING
HEATING
Ambie
n
t Te
m
p
eratur
e