Hitachi RAC-18WSPA Installation Manual Download Page 2

OUTDOOR UNIT

INST

ALLA

TION OFREFRIGERA

TING PIPES 

AND 

AIRREMOV

AL

CONNECTION OF POWER CORD

FINAL

 ST

AGE OF INST

ALLA

TION

L N C D

(A) (B)

30mm

10mm

10mm

70mm

10mm

50mm

10mm

50mm

D
C

C

D

AIR REMOV

AL

0LEASEFACETHISSIDESUCTION
SIDE OFTHEUNITTOTHEWALL

0LEASEREMOVESIDECOVER
WHENCONNECTINGTHEPIPING
ANDCONNECTINGCORD

0ULLDOWNWARD

s $ONOTTOUCHTHESUCTIONPORT

BOTTOMSURFACEORALUMINUM
lNOFTHEOUTDOORUNIT

 &AILURETODOSOMAYCAUSE

ANINJURY

1

Preparation of Pipe

3

Remove of Air From The Pipe And Gas Leakage Inspection

2

Pipe Connection

#OPPERPIPE

#OPPERPIPE

$IE

$IE

!

4RIMMINGTOOL

s 2EMOVEBURRANDJAGGEDEDGEWILLCAUSELEAKAGE
s 0OINTTHESIDETOBETRIMMEDDOWNWARDSDURINGTRIMMINGTOPREVENTCOPPER

CHIPSFROMENTERINGTHEPIPE

&LARENUT

7RENCH

4ORQUE
WRENCH

Procedures of using Vacuum Pump for Air Removal

1

2

3

4

!SSHOWNINRIGHTlGUREREMOVETHECAP
OF VALVE CORE4HEN CONNECT THE CHARGE
HOSE 2EMOVE THE CAP OF VALVE HEAD
#ONNECTTHEVACUUMPUMPADAPTERTOTHE
VACUUM PUMP AND CONNECT THE CHARGE
HOSETOTHEADAPTER

&ULLYTIGHTERTHE(ISHUTTLEOFTHEMANIFOLD
VALVE AND COMPLETELY UNSCREW THE ,O
SHUTTLE2UNTHEVACUUM PUMPFORABOUT
MINUTESTHENCOMPLETELYTIGHTENTHE
,O SHUTTLE AND SWITCH OFF THE VACUUM
PUMP
s ,OOSENTHESPINDLEOFTHESERVICEVALVE

WITH SMALL DIAMETER BY  TURN AND
TIGHTENTHESPINDLEIMMEDIATELYAFTER
TOSECONDS

s 2EMOVE THE CHARGING HOSE FROM THE

SERVICEVALVE

#OMPLETELY UNSCREW THE SPINDLE OF THE
SERVICEVALVEATPLACES INANTICLOCKWISE
DIRECTION TO ALLOW THE FLOW OF REFRIGERANT
USING(EXAGONAL7RENCHKEY

4IGHTENTHECAPOFVALVEHEAD#HECKTHE
CAPgSPERIPHERYIFTHEREISANYGASLEAKAGE
4HETASKISTHENCOMPLETED

0LEASEUSEGASLEAKAGEDETECTORTOCHECKIFLEAKAGE
OCCURS AT CONNECTION OF &LARE NUT AS SHOWN ON THE
RIGHT

)FGASLEAKAGEOCCURSFURTHERTIGHTENTHECONNECTION
TOSTOPLEAKAGE

7HENTHEMETER0A
CM(G  DURING PUMPING FULLY
TIGHTENTHESHUTTLE

-ETERSHOWING
PRESSURE

#HARGE
HOSE

2!
-ANIFOLD

6ACUUM

PUMP

6ACUUM
PUMP
ADAPTER

7HEN PUMPING STARTS SLIGHTLY
LOOSENTHEmARENUTTOCHECKOF
AIRSUCKEDIN4HENTIGHTENTHE
mARENUT

4HEBODYOFSERVICE
VALVE

#APOF
VALVECORE

(EXAGONAL
EY

#APOFVALVE
HEAD

#APOFVALVE
HEAD

#LOSED

VALVE

6ALVE

6ALVE

'ASLEAKAGEINSPECTION

WARNING

s 4()3!00,)!.#%-534"%

%!24(%$

Procedures of Wiring

)NDOOR5NIT

)NDOOR5NIT

'REEN9ELLOW

'REEN9ELLOW

'REEN9ELLOW

3TRIPWIRES

#ONNECTING#ORD

!#6
’(Z

#ONNECTINGCORD

#ONNECTINGCORD

!FTER REMOVE THE SCREW
AND TERMINAL COVER AND
PUTTHECONNECTINGCORDS
ANDlXTHETERMINALCOVER
WITHSCREW

%ARTH

$ETAILOFCUTTINGTHECONNECTINGCORD

’OR

’

/UTDOOR5NIT

/UTDOOR5NIT

Method to remove the low cover

s 4HENAKEDPARTOFTHEWIRECORESHOULDBEMMlXITTOTHETERMINALTIGHTLY4HEN

TRYTOPULLTHEINDIVIDUALWIRETOCHECKIFTHECONTACTISTIGHT)MPROPERINSERTIONMAY
BURNTHETERMINAL

s "ESURETOUSEONLYWIRESPECIlEDFORTHEUSEOFAIRCONDITIONER

s 0LEASEREFERTOTHEMANUALFORWIRECONNECTIONANDTHEWIRINGTECHNIQUESHOULD

MEETTHESTANDARDOFTHEELECTRICALINSTALLATION

s 4HEREISAN!#VOLTAGEDROPBETWEENTHE,.TERMINALIFTHEPOWERISON4HEREFORE

BESURETOREMOVETHEPLUGFROMITSSOCKET

s ,EAVE SOME SPACE IN THE CONNECTING CORD FOR MAINTENANCE

PURPOSEANDBESURETOSECUREITWITHTHECORDBAND

s 3ECURE THE CONNECTING CORD ALONG THE COATED PART OF THE WIRE

USINGTHECORDBAND$ONOTEXERTPRESSUREONTHEWIREASTHIS
MAYCAUSEOVERHEATINGORlRE

s .EVERREMODELTHEPOWERPLUGNOREXTENDTHELONGDISTANCE

CORD

s +EEPADDITIONALLENGTHFORTHEPOWERCORDANDDONOTRENDER

THEPLUGUNDEREXTERNALFORCEASTHISMAYCAUSEPOORCONTACT

s $ONOTlXTHEPOWERCORDWITH5SHAPENAIL
s 4HEPOWERCABLEEASILYGENERATESHEAT$ONOTBRINGTHE

CABLETOGETHERWITHAWIREORVINYLTIE

s 0LEASEENSURETHATTHEAIRCONDITIONERISINNORMALOPERATING

CONDITIONDURINGTHEOPERATIONTEST

s %XPLAINTOYOURCUSTOMERTHEPROPEROPERATIONPROCEDURESAS

DESCRIBEDINTHEUSERgSMANUAL

s )F THE INDOOR UNIT WONgT OPERATE CHECK THE CABLE FOR CORRECT

CONNECTION

s 4URNONTHELAMPINTHEROOMWHERETHEINDOORUNITISINSTALLED

ANDCHECKTHEREMOTECONTROLLERFORNORMALOPERATION

Wiring of The Indoor Unit

Wiring of the Outdoor Unit

s 0LEASEREMOVETHESIDECOVERFORWIRECONNECTION

Checking for the electric source and the voltage range

s "EFOREINSTALLATIONTHEPOWERSOURCEMUSTBECHECKEDANDNECESSARYWIRINGWORKMUST

BECOMPLETED4OMAKETHEWIRINGCAPACITYPROPERUSETHEWIREGAUGELISTBELOWFORTHE
WIRINGFROMHOUSEDISTRIBUTIONFUSEBOXTOTHEOUTDOORUNITINCONSIDERATIONOFTHEBLOCKED
ROTORCURRENT

s )NVESTIGATE THE POWER SUPPLY CAPACITY AND OTHER

ELECTRICALCONDITIONSATTHEINSTALLINGLOCATION

 $EPENDINGONTHEMODELOFROOMAIRCONDITIONERTOBE

INSTALLEDREQUESTTHECUSTOMERTOMAKEARRANGEMENTS
FORTHENECESSARYELECTRICALWORKETC

 4HE ELECTRICAL WORK INCLUDES THE WIRING WORK UP THE

OUTDOORUNIT)NLOCALITIESWHEREELECTRICALCONDITIONS
AREPOORUSEOFAVOLTAGEREGULATIONISRECOMMENDED

s )NSTALLOUTDOORFORTHEROOMAIRCONDITIONERWITHINTHE

REACHINGRANGEOFTHELINECORD

s &ORWIRECONNECTIONOFTHE)NDOORUNITYOUNEEDTOREMOVETHEFRONTCOVERTHELOWCOVER

UNDERTHEBODYOFTHEUNITANDTERMINALCOVER

s 2EMOVETHECOVERFROMTHETERMINALBASEANDSCREWTHECABLE

s "EFOREmARINGPLEASEPUTONTHEmARENUT

s 0LEASEBECAREFULWHENBENDINGTHECOPPERPIPE
s 3CREWINMANUALLYWHILEADJUSTINGTHECENTER!FTERTHATUSEATORQUEWRENCHTO

TIGHTENTHECONNECTION

s 0LEASEUSE

EXCLUSIVETOOLFOR
REFRIGERANT2!

/UTER

$IAMETERŒ 

!MM 2IGID&LARING4OOL

&OR2!TOOL

&OR2TOOL

 

 

s )NCASEOFREMOVINGmARENUTOFAINDOORUNITlRSTREMOVE

ANUTOFSMALLDIAMETERSIDEORASEALCAPOFBIGDIAMETER
SIDE WILL FLY OUT &REE FROM WATER INTO THE PIPING WHEN
WORKING

s "ESURETOTIGHTENTHEmARENUTTOTHESPECIlEDTORQUEWITH

ATORQUEWRENCH

 )FTHEmARENUTISOVERTIGHTENEDTHENUTMAYBESPLITAFTERA

LONGPERIODHASPASSEDANDMAYCAUSEAREFRIGERANTLEAK

/UTERDIAMETER

OFPIPE’ 

4ORQUE.qM

KGFqCM 

3MALLDIAMETERSIDE

  nn 

,ARGEDIAMETERSIDE

  nn 

6ALVE

HEADCAP

3MALLDIAMETERSIDE   nn 
,ARGEDIAMETERSIDE   nn 

6ALVECORECAP

nn 

1

2

s 0ULL AT THE

1

 AND

2

 IN

THEDIRECTIONSASSHOWN
BYARROWSTOREMOVETHE
COVER

How to connect the optional parts

(RAC Adapter, Weekly Timer Wired Remote Control, Wired Remote Control)

s &OR CABLE CONNECTION TO CONTROL 07" YOU NEED TO

REMOVEFRONTCOVERANDELECTRICALBOXCOVER

 %ACHCONNECTINGLOCATIONISASBELOW

1

 #ARD+EY#.

2

 (,).+#.

3

 7IRED2EMOTE#ONTROL#.

s 0LEASECHECKANDCONFIRMMANUALSATTACHEDTOEACH

OPTIONALPARTSFORMORECONNECTIONDETAILS

s 9OUCANREFERTOTHISINSTALLATIONMANUALHOWTOREMOVE

ANDREATTACHTHEFRONTCOVER

s 0LEASEBECAREFULNOTTODAMAGELEADWIRESBYEDGEOF

PLATEWHENCONNECTINGTHEOPTIONALPARTS

s )FYOUCANNOTATTACHTHESIDEPLATEDUETOTHECONNECTIONCORDPLEASE

PRESSTHECONNECTINGCORDINTHEDIRECTIONTOTHEFRONTPANELTOlXIT

s "ESURETHATTHEHOOKSOFTHESIDECOVERlXEDINCERTAINLY/THERWISE

WATERLEAKAGEMAYOCCURANDTHISCAUSESSHORTCIRCUITORFAULTS

s 4HECONNECTINGCORDSHOULDNOTTOUCHTOSERVICEVALVEANDPIPES

ITBECOMESHIGHTEMPERATUREINHEATINGOPERATION 

#.

#.

#.

WARNING

)-0/24!.4

)-0/24!.4

7IRELENGTH

7IREGAUGE

UPTO

M

MM

2

UPTOM

MM

2

UPTOM

MM

2

COVER

%ARTHTERMINAL

&USE#APACITY

!TIMEDELAYFUSE

Power Source And Operation Test

Power Source

Force-cooling operation

How to remove the front cover

How to Attach the Front Cover

Operation test

!FTERCOMPLETINGTHESERVICESWITCH
OPERATIONBESURETOKEEPTHESWITCH
PRESSEDFORONEORMORESECONDS
ANDSTOPTHEFORCECOOLINGOPERATION

s 7HENTHESERVICESWITCHOFTHEOUTDOORUNITISPRESSEDFOR

ORMORESECONDSTHEFORCECOOLINGOPERATIONSTARTS5SE
THISMODEWHENPERFORMINGTHEFAILUREDIAGNOSISORCOLLECTING
REFRIGERANTINTOTHEOUTDOORUNIT

3CREW

3ERVICESWITCH)FTHESWITCHISPRESSEDFORONE
ORMORESECONDSTHEFORCECOOLINGOPERATION
STARTS)FTHESWITCHISPRESSEDFORADDITIONAL
ONEORMORESECONDSTHEOPERATIONSTOPS 

s $ONOTOPERATETHEUNITFORMORETHAN

 MINUTES WHILE THE SPINDLE OF THE
SERVICEVALVEISCLOSED

1

 2EMOVETHEFRONTPANEL

2

 2EMOVETHElLTERS

3

 !FTERREMOVINGTWOSCREWSPULLTHECENTEROFTHEFRONTCOVER

TOWARDSYOUANDRELEASETHECLAWS

4

 0ULLTHESIDEFACESLOWERSECTIONS OFTHEFRONTCOVERTOWARDS

YOUASSHOWNINTHElGUREANDREMOVETHECOVER

s 0LEASEREMOVEANDATTACHTHEFRONTPANELBYBOTHHANDS

s !FTEROPENINGTHEFRONTPANELBYBOTHHANDS

1

 5NDOTHERIGHTARMWHILEPUSHINGITINSIDE

2

 3LIDETHEFRONTPANELTORIGHTASSHOWNINlGURE4HENREMOVE

WHILEPULLINGITTOFRONT

1

 #HECKTHATTHEDRAINPANISSECURELYATTACHED

2

 !FTERINSTALLINGTHEFRONTCOVERONTOTHEUNITHOOKTHREECLAWSAT

UPPERSIDEOFTHECOVERSECURELY4HENPUSHTHECENTEROFTHE
FRONTCOVERTOLOCKTHECLAWS

3

 4IGHTENTHETWOSCREWS

4

 )NSTALLTHElLTER

5

 3LIDETHESHAFTSOFTHERIGHTANDLEFTARMSONTHEFRONTPANEL

ALONGTHESTEPSTOINSERTTHESHAFTSINTOTHEHOLESTILLTHEYSTOP
!FTERCHECKINGTHATTHESHAFTSARESECURELYINSERTEDCLOSETHE
PANEL

HOW TO REMOVE INDOOR UNIT

s 0USHUPTHE;053(=SECTIONSATTHEBOTTOMOFTHEINDOORUNITAND

PULLTHEBOTTOMPLATETOWARDSYOU4HENTHECLAWSARERELEASED
FROMTHESTATIONARYPLATE

 4HE;053(=SECTIONSAREINDICATEDBYARROWSINTHERIGHTlGURE 

;053(=MARKPOSITIONS

s 0LEASEMOUNTTHE/UTDOORUNITOFSTABLEGROUNDTOPREVENTVIBRATIONANDINCREASE

OFNOISELEVEL

s $ECIDETHELOCATIONFORPIPINGAFTERSORTINGOUTTHEDIFFERENTTYPESOFPIPEAVAILABLE

s 7HEN REMOVINGSIDE COVER PLEASE PULL THE HANDLE AFTER UNDOING THE HOOK BY

PULLINGITDOWNWARD2EINSTALLTHESIDECOVERINTHEREVERSEORDEROFTHEREMOVAL

s 5SEAPIPECUTTERTOCUTTHECOPPERPIPEANDREMOVEBURR

CAUTION

CAUTION

CAUTION

WARNING

WARNING

WARNING

CAUTION

< 10030C :   >