Hitachi RAC-18WSPA Installation Manual Download Page 1

 

 

 

s

0LEASEREQUESTYOURSALESAGENTORQUALIlEDTECHNICIANTOINSTALLYOURUNIT7ATERLEAKAGESHORTCIRCUITORlREMAYOCCURIFYOUDOTHE
INSTALLATIONWORKYOURSELF

s

0LEASEOBSERVETHEINSTALLATIONSTATEDINTHEINSTALLATIONMANUALDURINGTHEPROCESSOFINSTALLATION)MPROPERINSTALLATIONMAYCAUSE
WATERLEAKAGEELECTRICSHOCKANDlRE

s

-AKESURETHATTHEUNITSAREMOUNTEDATLOCATIONSWHICHAREABLETOPROVIDEFULLSUPPORTTOTHEWEIGHTOFTHEUNITS)FNOTTHEUNITSMAY
COLLAPSEANDIMPOSEDANGER

s

/BSERVETHERULESANDREGULATIONSOFTHEELECTRICALINSTALLATIONANDTHEMETHODSDESCRIBEDINTHEINSTALLATIONMANUALWHENDEALING
WITHTHEELECTRICALWORK5SECABLESWHICHAREAPPROVEDOFlCIALINYOURCOUNTRY"ESURETOUSETHESPECIlEDCIRCUIT!SHORTCIRCUITAND
lREMAYOCCURDUETOTHEUSEOFLOWQUALITYWIREORIMPROPERWORK

s

"ESURETOUSETHESPECIlEDCABLESFORCONNECTINGTHEINDOORANDOUTDOORUNITS0LEASEENSURETHATTHECONNECTIONSARETIGHTAFTERTHE
CONDUCTORSOFTHEWIREAREINSERTEDINTOTHETERMINALSTOPREVENTTHEEXTERNALFORCEISBEINGAPPLIEDTOTHECONNECTIONSECTIONOFTHE
TERMINALBASE)MPROPERINSERTIONANDLOOSECONTACTMAYCAUSEOVERHEATINGANDlRE

s

0LEASEUSETHESPECIlEDCOMPONENTSFORINSTALLATIONWORK/THERWISETHEUNITMAYCOLLAPSEORWATERLEAKAGEELECTRICSHOCKlREOR
STRONGERVIBRATIONMAYOCCUR

s

"ESURETOUSETHESPECIlEDPIPINGSETFOR2!/THERWISETHISMAYRESULTINBROKENCOPPERPIPESORFAULTS

s

7HENINSTALLINGORTRANSFERRINGANAIRCONDITIONERTOANOTHERLOCATIONMAKESURETHATAIROTHERTHANTHESPECIlEDREFRIGERANT2!
DOESNOTENTERTHEREFRIGERATIONCYCLE)FOTHERAIRSHOULDENTERTHEPRESSURELEVELOFTHEREFRIGERATIONCYCLEMAYINCREASEABNORMALLY
WHICHCOULDRESULTINARUPTUREANDINJURY

s

"ESURETOVENTILATEFULLYIFAREFRIGERANTGASLEAKWHILEATWORK)FTHEREFRIGERANTGASCOMESINTOCONTACTWITHlREAPOISONOUSGASMAY
OCCUR

s

!FTERCOMPLETIONOFINSTALLATIONWORKCHECKTOMAKESURETHATTHEREISNOREFRIGERATIONGASLEAKAGE)FTHEREFRIGERANTGASLEAKSINTOTHE
ROOMCOMINGINTOCONTACTWITHlREINTHEFANDRIVENHEATERSPACEHEATERETCAPOISONOUSGASMAYOCCUR

s

5NAUTHORIZEDMODIlCATIONSTOTHEAIRCONDITIONERMAYBEDANGEROUS)FABREAKDOWNOCCURSPLEASECALLAQUALIlEDAIRCONDITIONER
TECHNICIANORELECTRICIAN)MPROPERREPAIRSMAYRESULTINWATERLEAKAGEELECTRICSHOCKANDlREETC

s

"ESURETOCONNECTTHEEARTHLINEFROMTHEPOWERSUPPLYWIRETOTHEOUTDOORUNITANDBETWEEN
THEOUTDOORANDINDOORUNIT$ONOTCONNECTTHEEARTHLINETOTHEGASTUBEWATERPIPELIGHTINGRODORTHEEARTHLINEOFTHE
TELEPHONEUNIT)MPROPEREARTHINGMAYCAUSEELECTRICSHOCKS

s

7HENlNISHINGTHEREFRIGERANTCOLLECTIONPUMPINGDOWN STOPTHECOMPRESSORANDTHENREMOVETHECOOLANTPIPE
)FYOUREMOVETHEREFRIGERANTPIPEWHILETHECOMPRESSORISOPERATINGANDTHESERVICEVALVEISRELEASEDAIRISSUCKEDANDA
PRESSUREINTHEFREEZINGCYCLESYSTEMWILLBUILDUPSTEEPLYCAUSINGANEXPLOSIONORINJURY

s

7HENINSTALLINGTHEUNITBESURETOINSTALLTHEREFRIGERANTPIPEBEFORESTARTINGTHECOMPRESSOR
)FTHEREFRIGERANTPIPEISNOTINSTALLEDANDTHECOMPRESSORISOPERATEDWITHTHESERVICEVALVERELEASEDAIRISSUCKEDANDTHE
PRESSURELEVELOFTHEREFRIGERATIONCYCLEMAYINCREASEABNORMALLYWHICHCOULDRESULTINARUPTUREANDINJURY

s

!CIRCUITBREAKERMUSTBEINSTALLEDINTHEHOUSEDISTRIBUTIONBOXFORTHEDIRECTCONNECTEDPOWERSUPPLYCABLESTOTHEOUTDOORUNIT
)NCASEOFOTHERINSTALLATIONSAMAINSWITCHWITHACONTACTGAPORMORETHANMMHASTOBEINSTALLED7ITHOUTACIRCUITBREAKERTHE
DANGEROFELECTRICSHOCKEXISTS

s

$ONOTINSTALLTHEUNITNEARALOCATIONWHERETHEREISmAMMABLEGAS4HEOUTDOORUNITMAYCATCHlRE
IFmAMMABLEGASLEAKSAROUNDIT

s

0LEASEENSURESMOOTHmOWOFWATERWHENINSTALLINGTHEDRAINHOSE)MPROPERINSTALLINGMAYWETYOURFUNITURE

s

!N)%#APPROVEDPOWERCORDSHOULDBEUSED0OWERCORDTYPE.9-

.O

)TEM

1TY

1

2

5

3

2

4

5

6

7

2

L.H

12

310

299

500

792

330

INDOOR UNIT

CAUTION

FOR SERVICE PERSONNEL ONLY

WARNING

Indoor Unit / Outdoor Unit

RAK-18PSPA/RAC-18WSPA

RAK-25PSPA/RAC-25WSPA

RAK-35PSPA/RAC-35WSPA

s 2EADTHESAFETYPRECAUTIONSCAREFULLYBEFOREOPERATINGTHEUNIT
s 4HECONTENTSOFTHISSECTIONAREVITALTOENSURESAFETY0LEASEPAYSPECIALATTENTIONTOTHEFOLLOWINGSIGN

 

WARNING  .......... Incorrect methods of installation may cause death or serious injury.

 

CAUTION  .......... Improper installation may result in serious consequence.

 

Make sure to connect earth line.

 

This sign in the figures indicates prohibition.

 

"ESURETHATTHEUNITOPERATESINPROPERCONDITIONAFTERINSTALLATION%XPLAINTOCUSTOMERTHEPROPEROPERATIONANDMAINTENANCEOF
THEUNITASDESCRIBEDINTHEUSERgSGUIDE!SKACUSTOMERTOKEEPTHISINSTALLATIONMANUALTOGETHERWITHTHEINSTRUCTIONMANUAL

SAFETY PRECAUTION

  WARNING

WARNING

WARNING

CAUTION

CAUTION

  CAUTION

THE CHOICE OF MOUNTING SITE

0LEASENOTETHEFOLLOWINGMATTERSANDOBTAINPERMISSIONFROMCUSTOMERBEFOREINSTALLATION 

INDOOR UNIT

OUTDOOR UNIT

s 4HEUNITSHOULDBEMOUNTEDATSTABLENONVIBRATORYLOCATION

WHICHCANPROVIDEFULLSUPPORTTOTHEUNIT

s 4HE/UTDOORUNITMUSTBEMOUNTEDATALOCATIONWHICH

CANSUPPORTHEAVYWEIGHT/THERWISENOISEANDVIBRATION
WILLINCREASE

s .ONEARBY HEATSOURCE ANDNOOBSTRUCTION NEARTHEAIR

OUTLETISALLOWED

s 4HE CLEARANCE DISTANCES FROM TOP RIGHT AND LEFT ARE

SPECIlEDINlGUREBELOW

s 4HELOCATIONMUSTBECONVENIENTFORWATERDRAINAGEAND

PIPECONNECTIONWITHTHE/UTDOORUNIT

s 4O AVOID INTERFERENCE FROM NOISE PLEASE PLACE THE UNIT

ANDITSREMOTECONTROLLERATLEASTMFROMTHERADIOAND
TELEVISION

s 4OAVOIDANYERRORINSIGNALTRANSMISSIONFROMTHEREMOTE

CONTROLLERPLEASEPUTTHECONTROLLERFARAWAYFROMHIGH
FREQUENCYMACHINESANDHIGHPOWERWIRELESSSYSTEMS

s $O NOT EXPOSE THE UNIT UNDER DIRECT SUNSHINE OR RAIN

"ESIDESVENTILATIONMUSTBEGOODANDCLEAROFOBSTRUCTION

s 4HEAIRBLOWNOUTOFTHEUNITSHOULDNOTPOINTDIRECTLYTO

ANIMALSORPLANTS

s 4HECLEARANCESOFTHEUNITFROMTOPLEFTRIGHTANDFRONTARE

SPECIlEDINlGUREBELOW!TLEASTTHREEOFTHEABOVESIDES
MUSTBEOPENAIR

s 4HEINSTALLATIONHEIGHTSHOULDBEATLEASTMMORMORE

FROMTHEmOOR

s "ESURETHATTHEHOTAIRBLOWNOUTOFTHEUNITANDNOISEDO

NOTDISTURBTHENEIGHBOURHOOD

s $ONOTINSTALLATALOCATIONWHERETHEREISmAMMABLEGAS

STEAMOILANDSMOKE

s 4HELOCATIONMUSTBECONVENIENTFORWATERDRAINAGE
s 0LACETHE/UTDOORUNITANDITSCONNECTINGCORDATLEAST

 M AWAY FROM THE ANTENNA OR SIGNAL LINE OF TELEVISION
RADIOORTELEPHONE4HISISTOAVOIDNOISEINTERFERENCE

.AMESOF)NDOOR#OMPONENTS

$IRECTIONOF0IPING

$IMENSIONOF-OUNTING

3TANDOFTHE/UTDOORUNIT

7HENTHEPOWERIS
SUPPLIEDFROMTHE
INDOORUNITPULLTHE
POWERCABLEFROMTHE
CABLEDRAWERATTHE
RIGHTORLEFTSIDEOF
THEINDOORUNIT

#ABLEDRAWERRIGHTSIDE 

4HERE ARE  DIRECTIONS ALLOWED
N A M E L Y  B A C K W A R D  P I P I N G 
B A CK WA R D  P I P I N G  F R O M  L E F T 
HORIZONTALLY PIPING FROM RIGHT
HORIZONTALLY PIPING FROM LEFT
VERTICALLYDOWNFROMRIGHTVERTICALLY
DOWNFROMLEFT

"ACKWARDPIPING
FROMLEFT

#ONNECTION

(ANGER

3CREWFOR(ANGER

!!!SIZE"ATTERY

2EMOTE#ONTROLLER

)NSULATIONSHEET

2EMOTE#ONTROLLER(OLDER

3CREWFOR2EMOTE
#ONTROLLER(OLDER

UNITMM 

-OUNTING
3TAND

Figure showing the Installation 
of Indoor and Outdoor Unit.

ABOVE
MM

Ć

ABOVEMM

Ć

ABOVEMM

0LUG

" E  S U R E  T O
COMPLETELY
SEALANYGAP
WITHPUTTY

ABOUTMM

M

USTNOTBEND

ABOUTM

MMORMORE

1

2

3

4

6

7

-AXIM

UMPIPELENGTHM

-INIM

UMPIPELENGTHM

4 H E  I N D O O R  P I P I N G  S H O U L D  B E
I N S U L A T E D  W I T H  T H E  E N C L O S E D
INSULATION PIPE )F THE INSULATOR IS
INSUFlCIENTPLEASEUSECOMMERCIAL
PRODUCTS 

s 4HEREFRIGERATINGMACHINEOILIS

EASILYAFFECTEDBYMOISTURE5SE
CAUTION TO PREVENT WATER FROM
ENTERINGTHECYCLE

s 4HEDIFFERENCEINHEIGHTBETWEEN

THE INDOOR AND OUTDOOR UNIT
SHOULDBEKEPTBELOWM

s 4HECONNECTINGPIPENOMATTER

BIG OR SMALL SHOULD ALL BE
INSULATEDWITHINSULATIONPIPEAND
THEN WRAPPED WITH VINYL TAPE
4HEINSULATORWILLDETERIORATEIFIT
ISNOTWRAPPEDWITHTAPE

4HE CONNECTION OF INSULATED DRAIN
HOSE

0LEASEUSEINSULATEDDRAINHOSEFOR
THE INDOOR PIPING COMMERCIAL
PRODUCT 

)NNERDIAMETERMM

Ć

GIVECLEARANCEASWIDEASPOSSIBLE

Ć

ABOVEMM

ABOVE

MM

Ć

ABOVEMM

ABOVEMM

ABOVEMM

4HECLEARANCESOFTHE
UNITFROMTOPLEFTRIGHT
ANDFRONTARESPECIlED
INlGUREBELOW!TLEAST
THREE OF THE ABOVE
SIDESMUSTBEOPENAIR

Ć

GIVECLEARANC
ASWIDEAS
POSSIBLE

ABOVEMMWHEN
INSTALLED ON THE
CEILINGOFBALCONY

 

1

2

Installation of Hanger, Wall Penetration and Installation of Protection Pipe

Installation Of The Indoor Unit

s 4HEDRAININGOFTHEWATERCONTAINERINSIDETHE)NDOORUNITCANBEDONEFROMTHE

LEFT4HEREFORETHEHANGERMUSTBElXEDHORIZONTALLYORSLIGHTLYTILTEDTOWARDSTHE
SIDEOFDRAINHOSE/THERWISECONDENSEDWATERMAYOVERmOWTHEWATERCONTAINER

Direct Mounting On The Wall

Procedures of Installation and Precautions

Installation Of Remote Controller

Wall Penetration and Installation of Protection Pipe

s 0LEASEUSEHIDDENBEAMSINTHEWALLTOHOLDTHEHANGER

6ISIBLEOUTLINEOFTHE

OUTDOORUNIT

$RAIN(OSE

,EVEL

,INE

7EIGHT

MM

MM

7ALLHOLE

(ANGER

3CREWFOR(ANGER

1

2

3CREWTHEHANGERATTHE
POSITIONSPOSSIBLYNEARTHE
UPPERANDLOWERHOOKSWHERE
THEINDOORUNITISHUNG5SEOR
MORESCREWSTOlXTHEHANGER

s0ROCEDURESTOlXTHEHANGER

s0ROCEDURESTOlXTHEHOLDEROFREMOTECONTROL

s 4HEREMOTECONTROLLERCANBEPLACEDINITSHOLDERWHICHISlXED

ONWALLORBEAM

s 4O OPERATE THE REMOTE CONTROLLER AT ITS HOLDER PLEASE ENSURE

THATTHEUNITCANRECEIVESIGNALTRANSMITTEDFROMTHECONTROLLER
ATTHEPLACEWHERETHEHOLDERISTOBE

 WHENSIGNALISRECEIVEDFROMTHEREMOTECONTROLLER4HESIGNAL

TRANSMISSION IS WEAKEN BY THE FLUORESCENT LIGHT4HEREFORE
DURING THE INSTALLATION OF THE REMOTE CONTROL HOLDER PLEASE
SWITCH ON THE LIGHT EVEN DURING DAY TIME TO DETERMINE THE
MOUNTINGLOCATIONOFTHEHOLDER

s $RILL A ’MM HOLE ON WALL WHICH IS

SLIGHTLYTILTEDTOWARDSTHEOUTDOORSIDE
$RILLTHEWALLATASMALLANGLE

s #UTTHEPROTECTIONPIPEACCORDINGTOTHE

WALLTHICKNESS

s %MPTY GAP IN THE SLEEVE OF PROTECTION

PIPESHOULDBECOMPLETELYSEALEDWITH
PUTTYTOAVOIDDRIPPINGOFRAINWATERINTO
THEROOM

s 0LEASE ENSURE SMOOTH FLOW OF WATER

WHENINSTALLINGTHEDRAINHOSE)MPROPER
INSTALLINGMAYWETYOURFUNITURE

s !N)%#APPROVEDPOWERCORDSHOULDBE

USED0OWERCORDTYPE.9-

s 4HE R UBBER STRAP USED FOR FIXING THE

INSULATORSHOULDNOTBETIEDWITHGREATFORCE
/THERWISETHISWILLDAMAGEHEATINSULATION
ANDCAUSESWATERCONDENSATION

s 0LEASEPULLTHELOWERPARTOFTHE)NDOORUNIT

OUTWARDSTOCHECKIFTHEUNITISHOOKEDONTO
THEHANGER)MPROPERINSTALLATIONMAYCAUSE
VIBRATIONANDNOISE

s 4RANSFORMTHEPIPINGWHILEHOLDINGDOWNTHE

LOWERPORTIONOFPIPESUPPORTBYHAND

$RILLHOLESONWALL

!SSHOWNBELOW 

$RILLHOLESONWALL

!SSHOWNBELOW 

0USHPLUGINTOTHEHOLES

!SSHOWNBELOW 

0USHPLUGINTOTHEHOLES

!SSHOWNBELOW 

&IXTHEHANGERONWALLWITH

XSCREW!SSHOWN
INlGUREBELOW 

7ALL

7ALL

7ALL

3CREW

3CREW

(ANGER

’MM

’MM

1

2

6

7

0LUG
0ROCURE
LOCALLY 

0LUG0ROCURELOCALLY 

#EILING

2EMOTE
#ONTROL
(OLDER

4HEREMOTECONTROLLER

MUSTBESLIDEINTHE

REMOTECONTROLLER

HOLDERINTHEDIRECTION

ASSHOWNINTHElGURE

UNTILITHOOKSATTHE

LOWERENDOFTHEREMOTE

CONTROLLERHOLDER

2EMOTE

#ONTROLLER

2EMOTE

#ONTROLLER

(OLDER

3CREWPIECES 

)NDOOR

/UTDOOR

MM

3EALWITH
PUTTY

3EALWITH
PUTTY

0ROTECTION
PIPE

3LEEVE OF
PROTECTION
PIPE

7!,,

"ESURETHATTHEWIREISNOT
INCONTACTWITHANYMETALIN
THE WALL 0LEASE USE THE
PROTECTION PIPE AS WIRE
PASSINGTHROUGHTHEHOLLOW
PART OF THE WALL SO AS TO
PREVENT THE POSSIBILITY OF
DAMAGEDBYMOUSE
5NLESSITSEALSCOMPLETELY
ANYAIRWITHHIGHHUMIDITY
mOWSFROMOUTDOORANDANY
DEWMAYDROP

Cutting Low Cover bush

s 7HILEINSTALLINGTHEPIPEFROMTHERIGHTLEFTOR

BOTTOMSIDEUSEAKNIFETOCUTOPENINGSAS
SHOWNINlGURE4HENSMOOTHENTHEEDGESOF
OPENINGSWITHAlLE

Changed of Drain Hose and Installation Procedures.

s %XCHANGETHELOCATIONOFDRAINHOSEANDDRAINCAPWHILEINSTALLINGTHEPIPEFROMTHELEFTSIDEAS

SHOWNINBELOW"ESURETOPLUGINTHEDRAINHOSEUNTILTHEINSULATINGMATERIALFOLDSUPONITSELF

s #ONNECTCONNECTINGCORD
s 0ULLOUTTHEPIPECONNECTINGCORDANDDRAINHOSE

s )NSERTTHEPIPETHROUGHTHEWALLHOLE

s 4HEREFRIGERATINGPIPESANDCONNECTINGCORD

TRANSFORMANDAREATTACHED

1

 4HE UPPER PART OF THE )NDOOR UNIT IS HANGED ON THE

HANGER

2

 4HEPROJECTIONATTHELOWERPARTOFTHE)NDOORUNITIS

HOOKEDONTOTHEHANGER

/PENINGS

/PENINGS

1

 

PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)

2

 

PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)

0REPARATION

)NSTALLATION

#ONNECTINGCORDSPIPEAND
DRAINHOSEMUSTBELAID
TOGETHERWITH6INYLTAPE

7ALLHOLE

0ROJECTION

0LIERS

$RAIN

(OSE

3CREW

0IPE

$RAINCAP

$RAINCAP

$RAINOUTLET

3OCKEHEAD

WRENCH’MM 

3OCKEHEAD

WRENCH’MM 

2UBBERSTRAPTIED
WITHGREATFORCE

4RANSFORMAFTER
BENDINGDOWNWARD

0IPE
SUPPORT

#ONNECTING#ORD

$RAIN(OSE

0ROTECTION
0IPE

2EFRIGERATING
0IPE

$RAINLAYOUTOF
BACKWARDPIPING

0IPE

0IPE

(ANGER

(ANGER

$RAINHOSE

#ABLE

1

1

,IFTTHEBODY
OFTHEUNIT
UPWARDSAND
THENFORCEIT
DOWNWARDS

1

2

0REPARATION

s 0LEASEUSEPLIERSTOPULL

OUTTHEDRAINCAP4HISIS
ANEASIERWAYTOREMOVE
THEDRAINCAP

)NSUFFICIENT INSERT MAY
RESULTINWATERLEAKAGE

s0USH THE PIPE DEEPLY UNTIL THE

INSULATINGSECTIONOFTHEDRAINHOSE
ENDGETSOVERTHERIBATTHEINDOOR
UNITSIDEANDlXITBYSCREW

s2EMOVELOWCOVER
s5SESOCKETHEADWRENCHTO)NSERT

DRAINCAPUPTOTHELOCATIONSECURELY

TILLTHECAPSTOPS

$RAIN(OSE

INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES

THE CONNECTION OF REFRIGERATING PIPE DURING 
THE INSTALLATION OF INDOOR UNIT 

s 4HEREFRIGERATINGPIPESHOULDBEADJUSTEDTOlTINTO

THE HOLE ON THE WALL AND THEN READY FOR FURTHER
CONNECTION

s 4HETERMINALSOFCONNECTEDPIPESMUSTBECOVERED

WITHINSULATORUSEDFORTERMINALCONNECTION4HENTHE
PIPESAREWRAPPEDWITHINSULATIONPIPE

s #ONNECT THE CONNECTING CORD AFTER REMOVING LOW

COVER

 2EFERTO#/..%#4)/./&0/7%2#/2$ 
s !FTERADJUSTMENTlTTHECONNECTINGCORDANDPIPES

INTOTHESPACEAVAILABLEUNDERTHEUNIT5SEHOLDERTO
HOLDTHEMTIGHT

s (OLDER CAN BE ATTACHED AT THE EITHER OF  PLACES

0LEASESELECTTHEEASIERPOSITION

$RAINHOSE

0ROJECTION

0ROJECTION

PIPE

(OOK

ABOUTCM

(OLDER

BELOW

MM

MM

#ONNECTING
CORD

)NSULATIONPIPEMUSTBEWRAPPEDWITH
VINYLTAPEATEVERYMM 

4HEENDOFTHEREFRIGERATINGPIPESAREAT
LOCATIONSMARKEDWITHh vSYMBOL

0LEASEBENDATASMALL
RADIUSTOFORMANARC

0REPARATION4O)NSTALL2EFRIGERATING0IPES

)NSTALLATION

(ANGTHEINDOORUNITONTOTHEHANGER5SETHETEMPORARYSTAND
AT THE BACK OF THE )NDOOR UNIT TO PUSH ITS LOWER PART CM
FORWARDS
s 0LACETHEDRAINHOSETHROUGHTHEHOLEONTHEWALL
s 7RAP THE REFRIGERATING PIPES WITH INSULATION PIPE AFTER

CONNECTINGREFRIGERATINGPIPE

s #ONNECTTHECONNECTINGCORDAFTERREMOVINGLOWCOVER
 2EFERTO#ONNECTIONOF0OWER#ORD 
s !FTERADJUSTMENTTHECONNECTINGCORDANDREFRIGERATINGPIPES

AREPLACEDINTOTHESPACEAVAILABLEUNDERTHE)NDOORUNIT

s 4HEPROJECTIONOF)NDOORUNITMUSTHOOKTOTHEHANGER

$RAINHOSE

#ONNECTINGCORD

#ONNECTED
SECTION

)NSULATIONMATERIALFORPIPE
CONNECTION

3LEEVEOF
PROTECTIONPIPE

0ULLTHISTOTHEFRONTDURINGTHE
CONNECTIONOFREFRIGERATING
PIPETOEASETASK

#ONNECTING

CORD

2EFRIGERATING

PIPE

7ALLHOLE

$RAINHOSE

$RAINLAYOUTOFBACKWARDPIPINGFROMLEFT

0IPE

#ABLE

(EAT

INSULATIONPIPE

3

Heat Insulation and Finish of the Piping

4

Installation of Drain Hose

s 4HECONNECTEDTERMINALSSHOULDBECOMPLETEDSEALED

WITHHEATINSULATORANDTHENTIEDUPWITHRUBBERSTRAP

s $ONOTTIETHETERMINALSWITHTHETAPETOOTIGHT
 )F ANY CLEARANCE OR OVERTIGHTENING MAY CAUSE

CONDENSATION

s 0LEASETIETHEPIPEANDPOWERLINETOGETHERWITHVINYL

TAPEASSHOWNINTHElGURESHOWINGTHEINSTALLATIONOF
)NDOORAND/UTDOORUNITS

s 4OENHANCETHEHEATINSULATIONANDTOPREVENTWATER

CONDENSATION PLEASECOVERTHEOUTDOORPARTOFTHE
DRAINHOSEANDPIPEWITHINSULATIONPIPE

s #OMPLETELYSEALANYGAPWITHPUTTY

0UTTY

0UTTY

"ENDINGUPWARDS #ONDENSEDWATER

POND

#ONDENSEDWATER

POND

$ITCH

"ESURETHATTHEDRAINHOSEIS
NOTLOOSELYCONNECTEDBENDOR
PROPERCONDITIONLIKELEFTlGURE

9OUAREFREETOCHOOSETHESIDELEFTORRIGHT FORTHEINSTALLATIONOFDRAIN
HOSE0LEASEENSURETHESMOOTHmOWOFCONDENSEDWATEROFTHE)NDOOR
UNITDURINGINSTALLATION#ARELESSMAYRESULTINWATERLEAKAGE 

CAUTION

CAUTION

CAUTION

CAUTION

Reviews: