OUTDOOR UNIT

Please mount the outdoor unit on stable ground to prevent

vibration and increase of noise level.

Decide the location for piping after sorting out the different

types of pipe available.

Open the side plate by unscrewing the screws as shown below.

Removal Of Air From The Pipe And Gas Leakage Inspection

Gas Leakage Inspection

Please use gas leakage detector to check if leakage
occurs at the connection of Flare nut as shown on
the right.

If gas leakage occurs, further tighten the connection
to stop leakage.

FINAL ST

A

GE OF INST

ALLA

TION

Insulation And Maintenance Of Pipe Connection

1

The connected terminals should be completed sealed with
heat insulator and then tied up with rubber strap.

Please tie the pipe and power line together with vinyl tape as
shown in the figure showing the installation of indoor and
outdoor units. Then fix their position with holders.

To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.

Completely seal any gap with putty.

  Installation Of Remote Controller

2

  Power Source And Operation Test

3

The remote controller can be placed in its holder which is
fixed on wall or beam.

To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be fixed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the florescent light. Therefore, during
the installation of the remote control holder, please switch on
the light, even during day time, to determine the mounting
location of the holder.

Power Source

CAUTION

!

Please use a new socket. Accident may occur due to the use of old
socket because of poor contact.

Please plug in and then remove the plug for 2 – 3 times. This is to
ensure that the plug is completely plugged into the socket.

Keep additional length for the power cord and do not render the
plug under external force as this may cause poor contact.

Do not fix the power cord with U-shape nail.

Operation Test

Please ensure that the air conditioner is in normal operating condition
during the operation test.

Explain to your customer the proper operation procedures as
described in the user’s manual.

Insulation material for pipe connection

Sleeve of
protection pipe

Putty

<

I699: A 

>

The controller must be hooked onto the hook at the lower
part of the holder. Push in the remote controller in the direction
as shown in figure below.

3

Procedures of using Vacuum Pump for Air Removal

As shown in figure on the right, remove
the cap of valve head and valve core
and then connect them to the vacuum
pump and manifold valve.

Fully tighten the “Hi” shuttle of the
manifold valve and completely unscrew
the  “Lo” shuttle. Run the vacuum pump
for about 10–15 minutes, then completely
tighten the “Lo” shuttle and switch off
the vacuum pump.

2

Completely unscrew the spindle of the
service valve (at 2 places) in anti-
clockwise direction to allow the flow of
coolant (using Hexagonal Wrench key).

3

Remove the Charge hose and tighten
the cap of valve head. The task is then
completed.

4

1

   Preparation of Pipe

1

Use a pipe cutter to cut the copper pipe.

Jagged edge will cause leakage.

Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.

Before flaring, please put on the flare nut.

   Pipe Connection

2

INST

ALLA

TION OF REFRIGERA

TING PIPES AND AIR REMO

VA

L

CAUTION

!

Outer

diameter

of pipe

6.35 (1/4")

12.7 (1/2")

Valve head cap

Valve core cap

Torque N.m

(kgf 

 cm)

13.7  – 18.6 (140 – 190)

44.1  – 53.8 (450 – 550)

19.6  – 24.5 (200 – 250)

12.3  – 15.7 (125 – 160)

Copper pipe

Trimming tool

Outer

Diameter (ø)

6.35 (1/4")

12.7 (1/2")

Imperial flaring tool

0.8  – 1.5

1.0  – 2.0

Rigid flaring tool

0  – 0.5

0  – 1.0

A (mm)

Small diameter

side

Big diameter

side

AIR REMO

V

A

L

Remote

Controller

Holder for
Remote Controller

Screw (2 pieces)

WARNING

You may not be able to close the side cover due to the
connecting cord, under such situation, please press against
the wall of side cover to fix it.

Be sure that the hooks (2 places) are plugged in.
Otherwise, water leakage may occur and this causes short
circuit or faults.

The naked part of the wire core should be 10 mm and the insulated part of the wire must be push into the terminal for
3  – 4 mm. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal.

Be sure to use only wire specified for the use of air-conditioner.

Please refer to the installation manual for wire connection and the wiring technique should meet the standards of electrical
installation.

How to Remove the Front
Cover

Open the cover    and remove the screw.

After open the front panel, remove the screw and open
the
cover   , disconnect the wire connector   .

Remove the filter, release the axis by pulling the center
portion of front cover in the direction of arrow   .

Push vertical air deflector handle to the right or left side.

After raise the front cover from bottom side as    , release
the front cover by pull the right or left sides as   .

How to Install the Front Cover

Insert the two hooks    at the upper side certainly.

Open Front Panel, push the center down in the direction
of the arrow to insert the axis at the center of the front
cover into the hook at the outlet frame.

Connect the wire connetor    , fixed the screw and cover

      and    .

Checking for the electric source
and the voltage range

Before installation, the power source must be checked and
necessary wiring work must be completed. To make the
proper wiring capacity, use the wire gauges list below for the
lead-in from a pole transformer and for the wiring from a switch
board of fuse box to the outlet in consideration of the locked
rotor current.

Investigate the power supply capacity and other
electrical conditions at the installation location.
Depending on the model of room air conditioner
to be installed, request the customer to make
arrangements for the necessary electrical work etc.
The electrical work includes the wiring work up
the outlet. In localities where electrical conditions
are poor, use of a voltage regulation is
recommended.

USE 15A time delay FUSE

IMPORTANT

Wire length

up to 

1

6m

up to 10m
up to 15m
up to 25m
up to 42m

Wire gauge

1.6mm (B.S. 14)
2.0mm (B.S. 12)
2.6mm (B.S. 10)
3.2mm (B.S. 

1

8)

14mm

2

 (B.S. 

1

6)

IMPORTANT

THIS APPLIANCE MUST BE EARTHED.

Procedures of  Wiring

Connect the electrical wiring between the indoor and outdoor unit as shown in below Fig.
Never connect the wiring by mistake.

The connection cord must be fixed by the band which is located on the electrical box.

Wiring Of  The Outdoor Unit

Please remove the side cover for wire connection.

!

WARNING

!

CONNECTION OF POWER CORD

A

Die

Die

Copper pipe

Wrench

Torque
wrench

Flare nut

Lo

Hi

Meter showing pressure

Manifold valve

Vacuum pump

Charge
hose

When pumping starts, slightly loosen
the flare nut to check of air sucked in.
Then tighten the flare nut.

When the meter reaches –101KPa (–76cmHg)
during pumping, fully tighten the shuttle.

The body of
service valve

Cap of
valve core

Hexagonal
Wrench Key

Cap of valve head

Cap of valve head

CAUTION

!

In case of removing Flare nut of a cooling unit, first remove a nut of
small diameter side, or else seal cap of big diameter side will fly out.

Please be careful when bending the copper pipe.

Applied frozen grease to the connection points and then screw in manually. After that,
use a torque wrench to tighten the connection.

WARNING

!

Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not
reach the specified capacity.

Detail of cutting the connecting cord

To remove the connecting wires
for the indoor unit, please remove
the low cover panel in front of
the unit.

A

B

A

B

(L) Brown

(N) Blue

Terminal Board

Line Cord

Terminal Board

Green & Yellow

Green &

Yellow

Outdoor Unit

Indoor Unit

Indoor

Unit

Outdoor

Unit

GRN + YEL

10mm

30mm

30mm

10mm

GRN + YEL

70mm

35mm

10mm

Please face this side (suction
side) of the unit to the wall.

Please remove side cover
when connecting the piping
and connecting cord.

Pull downward

Connect the
earth cord

After remove the
screw and band,
put the connecting
cords and fix the
band with screw.

Earth terminal

B

A

A

B

Wiring Of The Indoor Unit

For wire connection of the Indoor unit, you need to remove front panel and electrical cover.
Method to remove front panel

Refer to “How to Remove The Front Cover”.

Method to remove electrical cover

Remove the screw and electrical cover.

Insert the connecting cord (A, B) from the bottom of unit.

Fixed the wire to terminal wires firmly as shown in figure at right side.

AUTO

RESTART

SWITCH

Electrical cover

Screw

CAUTION

!

Please make sure to remove all spacers inside the unit.

Open the Top, Back and Side cover of the unit.

Pull out the spacers inside.

(Spacers are only for transportation purpose).

If not remove, vibration and noise will occur.

Top cover

Back cover

Side cover

1

6

7

2

3

4

5

7

1

6

1

2

1

3

4

Screw

Cover

Front panel

Front Cover

Vertical Air Deflector Handle

Screw

7

6

5

5

1

1

2

2

RAS-13CE9/RAC-13CE9 (2) EN

24/3/05, 2:04 PM

1

Reviews: