OUTDOOR UNIT
●
Please mount the outdoor unit on stable ground to prevent
vibration and increase of noise level.
●
Decide the location for piping after sorting out the different
types of pipe available.
●
Open the side plate by unscrewing the screws as shown below.
Removal Of Air From The Pipe And Gas Leakage Inspection
Gas Leakage Inspection
Please use gas leakage detector to check if leakage
occurs at the connection of Flare nut as shown on
the right.
If gas leakage occurs, further tighten the connection
to stop leakage.
FINAL ST
A
GE OF INST
ALLA
TION
Insulation And Maintenance Of Pipe Connection
1
●
The connected terminals should be completed sealed with
heat insulator and then tied up with rubber strap.
●
Please tie the pipe and power line together with vinyl tape as
shown in the figure showing the installation of indoor and
outdoor units. Then fix their position with holders.
●
To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose
and pipe with insulation pipe.
●
Completely seal any gap with putty.
Installation Of Remote Controller
2
Power Source And Operation Test
3
●
The remote controller can be placed in its holder which is
fixed on wall or beam.
●
To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller
at the place where the holder is to be fixed. The unit will beep
when signal is received from the remote controller. The signal
transmission is weaken by the florescent light. Therefore, during
the installation of the remote control holder, please switch on
the light, even during day time, to determine the mounting
location of the holder.
Power Source
CAUTION
!
●
Please use a new socket. Accident may occur due to the use of old
socket because of poor contact.
●
Please plug in and then remove the plug for 2 – 3 times. This is to
ensure that the plug is completely plugged into the socket.
●
Keep additional length for the power cord and do not render the
plug under external force as this may cause poor contact.
●
Do not fix the power cord with U-shape nail.
Operation Test
●
Please ensure that the air conditioner is in normal operating condition
during the operation test.
●
Explain to your customer the proper operation procedures as
described in the user’s manual.
Insulation material for pipe connection
Sleeve of
protection pipe
Putty
<
I699: A
>
The controller must be hooked onto the hook at the lower
part of the holder. Push in the remote controller in the direction
as shown in figure below.
3
Procedures of using Vacuum Pump for Air Removal
As shown in figure on the right, remove
the cap of valve head and valve core
and then connect them to the vacuum
pump and manifold valve.
Fully tighten the “Hi” shuttle of the
manifold valve and completely unscrew
the “Lo” shuttle. Run the vacuum pump
for about 10–15 minutes, then completely
tighten the “Lo” shuttle and switch off
the vacuum pump.
2
Completely unscrew the spindle of the
service valve (at 2 places) in anti-
clockwise direction to allow the flow of
coolant (using Hexagonal Wrench key).
3
Remove the Charge hose and tighten
the cap of valve head. The task is then
completed.
4
1
Preparation of Pipe
1
●
Use a pipe cutter to cut the copper pipe.
●
Jagged edge will cause leakage.
●
Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
●
Before flaring, please put on the flare nut.
Pipe Connection
2
INST
ALLA
TION OF REFRIGERA
TING PIPES AND AIR REMO
VA
L
CAUTION
!
Outer
diameter
of pipe
6.35 (1/4")
12.7 (1/2")
Valve head cap
Valve core cap
Torque N.m
(kgf
●
cm)
13.7 – 18.6 (140 – 190)
44.1 – 53.8 (450 – 550)
19.6 – 24.5 (200 – 250)
12.3 – 15.7 (125 – 160)
Copper pipe
Trimming tool
Outer
Diameter (ø)
6.35 (1/4")
12.7 (1/2")
Imperial flaring tool
0.8 – 1.5
1.0 – 2.0
Rigid flaring tool
0 – 0.5
0 – 1.0
A (mm)
Small diameter
side
Big diameter
side
AIR REMO
V
A
L
Remote
Controller
Holder for
Remote Controller
Screw (2 pieces)
WARNING
●
You may not be able to close the side cover due to the
connecting cord, under such situation, please press against
the wall of side cover to fix it.
●
Be sure that the hooks (2 places) are plugged in.
Otherwise, water leakage may occur and this causes short
circuit or faults.
●
The naked part of the wire core should be 10 mm and the insulated part of the wire must be push into the terminal for
3 – 4 mm. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal.
●
Be sure to use only wire specified for the use of air-conditioner.
●
Please refer to the installation manual for wire connection and the wiring technique should meet the standards of electrical
installation.
How to Remove the Front
Cover
●
Open the cover and remove the screw.
●
After open the front panel, remove the screw and open
the
cover , disconnect the wire connector .
●
Remove the filter, release the axis by pulling the center
portion of front cover in the direction of arrow .
●
Push vertical air deflector handle to the right or left side.
●
After raise the front cover from bottom side as , release
the front cover by pull the right or left sides as .
How to Install the Front Cover
●
Insert the two hooks at the upper side certainly.
●
Open Front Panel, push the center down in the direction
of the arrow to insert the axis at the center of the front
cover into the hook at the outlet frame.
●
Connect the wire connetor , fixed the screw and cover
and .
Checking for the electric source
and the voltage range
●
Before installation, the power source must be checked and
necessary wiring work must be completed. To make the
proper wiring capacity, use the wire gauges list below for the
lead-in from a pole transformer and for the wiring from a switch
board of fuse box to the outlet in consideration of the locked
rotor current.
●
Investigate the power supply capacity and other
electrical conditions at the installation location.
Depending on the model of room air conditioner
to be installed, request the customer to make
arrangements for the necessary electrical work etc.
The electrical work includes the wiring work up
the outlet. In localities where electrical conditions
are poor, use of a voltage regulation is
recommended.
USE 15A time delay FUSE
IMPORTANT
Wire length
up to
1
6m
up to 10m
up to 15m
up to 25m
up to 42m
Wire gauge
1.6mm (B.S. 14)
2.0mm (B.S. 12)
2.6mm (B.S. 10)
3.2mm (B.S.
1
8)
14mm
2
(B.S.
1
6)
IMPORTANT
●
THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring
●
Connect the electrical wiring between the indoor and outdoor unit as shown in below Fig.
Never connect the wiring by mistake.
●
The connection cord must be fixed by the band which is located on the electrical box.
Wiring Of The Outdoor Unit
●
Please remove the side cover for wire connection.
!
WARNING
!
CONNECTION OF POWER CORD
A
Die
Die
Copper pipe
Wrench
Torque
wrench
Flare nut
Lo
Hi
Meter showing pressure
Manifold valve
Vacuum pump
Charge
hose
When pumping starts, slightly loosen
the flare nut to check of air sucked in.
Then tighten the flare nut.
When the meter reaches –101KPa (–76cmHg)
during pumping, fully tighten the shuttle.
The body of
service valve
Cap of
valve core
Hexagonal
Wrench Key
Cap of valve head
Cap of valve head
CAUTION
!
In case of removing Flare nut of a cooling unit, first remove a nut of
small diameter side, or else seal cap of big diameter side will fly out.
●
Please be careful when bending the copper pipe.
●
Applied frozen grease to the connection points and then screw in manually. After that,
use a torque wrench to tighten the connection.
WARNING
!
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not
reach the specified capacity.
Detail of cutting the connecting cord
To remove the connecting wires
for the indoor unit, please remove
the low cover panel in front of
the unit.
A
B
A
B
(L) Brown
(N) Blue
Terminal Board
Line Cord
Terminal Board
Green & Yellow
Green &
Yellow
Outdoor Unit
Indoor Unit
Indoor
Unit
Outdoor
Unit
GRN + YEL
10mm
30mm
30mm
10mm
GRN + YEL
70mm
35mm
10mm
Please face this side (suction
side) of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Pull downward
Connect the
earth cord
After remove the
screw and band,
put the connecting
cords and fix the
band with screw.
Earth terminal
B
A
A
B
Wiring Of The Indoor Unit
●
For wire connection of the Indoor unit, you need to remove front panel and electrical cover.
Method to remove front panel
●
Refer to “How to Remove The Front Cover”.
Method to remove electrical cover
●
Remove the screw and electrical cover.
●
Insert the connecting cord (A, B) from the bottom of unit.
●
Fixed the wire to terminal wires firmly as shown in figure at right side.
AUTO
RESTART
SWITCH
Electrical cover
Screw
CAUTION
!
Please make sure to remove all spacers inside the unit.
●
Open the Top, Back and Side cover of the unit.
●
Pull out the spacers inside.
(Spacers are only for transportation purpose).
If not remove, vibration and noise will occur.
Top cover
Back cover
Side cover
1
6
7
2
3
4
5
7
1
6
1
2
1
3
4
Screw
Cover
Front panel
Front Cover
Vertical Air Deflector Handle
Screw
7
6
5
5
1
1
2
2
RAS-13CE9/RAC-13CE9 (2) EN
24/3/05, 2:04 PM
1