Switching power circuit
Fig. 1-1
·
An AC power supply from outdoor unit passes through the 3.15 A fuse, varistor (VA001), and noise filter circuit and rectified
and smoothed by DB1 and C003 to become a DC current 325 V. It is then supplied to indoor fan motor drive circuit,and
switching power circuit.
·
The switching power circuit, as controlled by IC001, drives the primary winding of the transformer (T001) to produce a
specified voltage at the output winding. [The output terminal (pin ) of IC001 has a switching voltage. But it changes in
voltage peak and oscillation period depending on the power load. usually,the oscillation frequency when the air condition
operation is about 67 kHz. In the standby state, the oscillation frequency is lowered to a level as low as 20 kHz or so to
reduce the standby power.]
①
·
The outputs of the output windings of the transformer is rectified and smoothed to become DC voltages at primary 18.5 V,
12 V, and 8.5 V respectively. The primary 18.5 V is supplied to the drive circuit of the indoor fan motor, the 12 V is supplied
to each vane motor and to the drive circuits of the cleaning unit driving motor and other equipment, and the 8.5 V is adjusted
to a stable 5 V by the 3-terminal regulator IC (IC101,IC103) and supplied to the microcomputer peripheral circuit.
If a failure in a part or circuit has produced an abnormal current in the power supply, the 3.15 A fuse will melt down to
prevent further damage. If the 3.15 A fuse melts down, check the indoor fan motor, switching electrical circuit, and other
components and replace any defective part.
If an abnormally high voltage is applied to the power supply, the 3.15 A fuse and varistor (VA001) will prevent further
damage. If a high voltage results in the 3.15 A fuse melted down, the varistor (VA001) should have deteriorated and
destroyed. Therefore replace it at the same time.
The primary circuit of the transformer (T001) has a voltage to ground. Guard against electric shocks.
Check
Check
Caution
1. Control power circuit
DESCRIPTION OF MAIN CIRCUIT OPERATION
MODEL RAK-18/25/35/50PEC
RAK-25/35/50PECC
RAK-10/14/20PECI
Summary of Contents for RAC-10WECI
Page 2: ... DANGER ...
Page 9: ... ...
Page 10: ... ...
Page 11: ... ...
Page 13: ... ...
Page 14: ... ...
Page 15: ... ...
Page 26: ...MODEL RA C 18 25 35 W EC RAC 10 14WECI ...
Page 27: ...MODEL RAC 50WEC RAC 20WECI ...
Page 41: ... MODEL RAK 50PEC RAK 20PECI RAC 50WEC RAC 20WECI 1 2 1 2 1 2 1 2 RAK 50PECC ...
Page 53: ...L N 300 330 Main parts C021 C022 375 420V L N 15 MODEL RAC 18 25 35WEC RAC 10 14WECI ...
Page 57: ...5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 ...
Page 59: ...2A Fuse DC300 330V 7 7 1 ...
Page 60: ...2A DC300 330V ...
Page 61: ...L N 300 330 L N MODEL RAC 50WEC RAC 20WECI ...
Page 62: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 ...
Page 66: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 ...
Page 68: ...2A Fuse DC300 330V 7 1 7 ...
Page 69: ...2A DC300 330V ...
Page 79: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 18 25 35WEC RAC 10 14WECI ...
Page 80: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50WEC RAC 20WECI ...