2. Indoor fan does not operate (others are normal)
Can the fan be stopped by remote
control?
The microcomputer fan PWM
output (at pin ) is 1-5V.
Replace the microcomputer.
Replace the fan motor.
Replace the microcomputer.
Perform final operation check.
3. Air deflector does not move (others are normal)
Are pulse signals output at
microcomputer pins - when
auto swing is turned on in the fan
mode?
Replace the microcomputer.
Is a voltage over 15 or below 10V
being generated on the 12V line?
Replace IC111.
Yes
Yes
Yes
Yes
No
No
No
No
Check IC711. If it is normal,
replace the air deflector motor.
Perform final operation check.
24
15
18
93
Summary of Contents for RAC-08PH1
Page 18: ...CONSTRUCTION AND DIMENSIONAL DIAGRAM OUTDOOR UNIT MODEL RAC 08PH1 RAC 10PH1 18 ...
Page 23: ...CIRCUIT DIAGRAM MODEL RAS 08PH1 RAS 10PH1 RAS 14PH1 23 ...
Page 24: ...1 H P 0 1 C A R 1 H P 8 0 C A R L E D O M 24 ...
Page 25: ...RAC 14PH1 MODEL L N 25 ...
Page 26: ...RAS_AW_022_A3e 22 RAS 08PH1 RAC 08PH1 RAS 10PH1 RAC 10PH1 RAS 14PH1 RAC 14PH1 26 ...
Page 36: ...MODEL RAS 08PH1 RAC 08PH1 MODEL RAS 14PH1 RAC 14PH1 RAS 10PH1 RAC 10PH1 36 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 55: ...55 ...
Page 56: ...56 ...
Page 57: ...57 ...
Page 59: ...59 ...
Page 80: ... JQ J E G J JQ _ G Z E q q z q z E KQ K _ E KQ K J Z KQ K E E G G 80 ...
Page 81: ... E E G G E E E Z E E H E Z E Q E E G G G E E 81 ...
Page 89: ...SELF DIAGNOSIS LIGHTING MODE 1 H P 4 1 C A R L E D O M 89 ...
Page 95: ...95 ...
Page 99: ...99 ...
Page 100: ...100 ...
Page 101: ...101 ...
Page 108: ...PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 08PH1 RAS 10PH1 RAS 14PH1 30 108 ...
Page 114: ...HITACHI RAS 08PH1 RAC 08PH1 RAS 10PH1 RAC 10PH1 83 HHAW NO 00 E RAS 14PH1 RAC 14PH1 114 ...