– 32 –
MAIN PARTS COMPONENT
THERMOSTAT (Room Temperature Thermistor)
Thermostat Specifications
FAN MOTOR
Fan Motor Specifications
CONNECTION
INDICATION
16
INDICATION
24
INDICATION
32
MODEL
THERMOSTAT MODEL
IC
OPERATION
COOL
HEAT
ON
17.3 (63.1)
18.0 (64.4)
OFF
16.7 (62.1)
18.6 (63.4)
ON
25.3 (77.5)
26.0 (78.8)
OFF
24.7 (76.5)
26.6 (77.8)
ON
33.3 (91.9)
34.0 (93.2)
OFF
32.7 (90.9)
34.6 (92.2)
MODEL
RAS-08CH9/10CH9/14CH9
RAS-08CH9(B)/10CH9(B)/14CH9(B)
RAC-08CH9/10CH9/14CH9
PHASE
RATED VOLTAGE
– – – – –
SINGLE
RATED FREQUENCY
DC35V
220-240V
TEMPERATURE
°
C (
°
F)
OUTPUT
POLE NUMBER
– – – – –
6
20 W
20W
30W
30W
– – – – –
50 Hz
35V
5V
RED
YELLOW
BLUE
M
BLACK
CAPACITOR
RA
RED
INTERNAL
THERMAL FUSE
GRAY
RM
RESISTANCE VALUE
( )
20
°
C
75
°
C
– – – – –
– – – – –
RM = 344.2
RA = 245.3
RM = 263.0
RA = 165.5
RM = 250.0
RA = 166.0
RM = 418.6
RA = 298.3
RM = 319.8
RA = 201.3
RM = 304.0
RA = 201.9
RAS-08CH9/10CH9/14CH9
RAS-08CH9(B)/10CH9(B)/14CH9(B)