Hitachi RAC-07G4 Information Booklet & User Manual Download Page 8

High Energy Efficiency

Hitachi conforms to the
2002/31/EC Directive – 92/75/EEC
“Energy labelling Directive (ELD)” ,
which is applicable from June 2004
on all air conditioning products up
to 12Kw cooling capacity. The DC
inverter PAM technology helps us
to achieve the ‘A’ class, the highest
level of energy efficiency which is
clearly indicated on the standard
labelling system.  

Adv

a

nt

a

ges include:

R

a

pid st

a

rt up

The variable speed compressor
(inverter) enables the system to
rapidly reach the desired room
temperature setting. Once the
desired room temperature has been
achieved the compressor rotation
speed is reduced, saving up to 30%
in energy usage (when compared to
conventional systems) without
compromising comfort levels.

Improved perform

a

nce

The inclusion of a DC driven motor
delivers an enhanced performance
over standard AC motor driven
systems. This enhanced performance
can be as much as 10%! 

Features and benefits

R

a

pid St

a

rt Up

Improved Perform

a

nce

PAM – Minimised loss 
of perform

a

nce

Hitachi’s PAM (Power Active Module)
control system mirrors the current
pulse waveform to avoid distortion
and therefore achieve almost 
100% power factor to enhance
power efficiency. This cutting edge
device is employed in all Hitachi
Mono/Multizone products for your
comfort and energy saving for our
environment. It ensures the efficient
use of input power and minimises
loss to less than 1%. The PAM
range boasts an industry leading
COP of more than 4.0.

All DC Inverter

As you would expect from an
Industry leader such as Hitachi, 
we have been at the forefront of
technological development and
advancement. As the pioneer 
of ‘DC’ Inverter driven Room 

Air Conditioners, our units boast
the significant advantage of all 
DC Inverter driven compressors
and fans. Enhanced inverter
performance and system
performance are achieved by 
the addition of a ‘DC’ drive. 

Convention

a

l Inverter

PAM Inverter

Summary of Contents for RAC-07G4

Page 1: ...room air conditioners Models Monozone Multizone NH5 NH6 NH7 QH5 Summit YH5 FH5 YH6 Monoduct DH7 Bigflow GH4 G4 Air Exchanger JX5 ROOM AIR CONDITIONERS ...

Page 2: ......

Page 3: ...rofile 4 Standards and quality certificates 5 Product range overview 6 General features and benefits 8 Monozone Multizone range 12 Summit range 52 Monoduct range 58 Bigflow range 60 Air Exchanger range 62 Contents ...

Page 4: ...r conditioning systems and water chillers which have revolutionised air conditioning worldwide The majority of our room air conditioning products are developed at our Tochigi Works in Japan This is the main focus not only for production but also for research and development with respect to all our room air conditioning products To assist in production and distribution worldwide we have seven affil...

Page 5: ...nvironmental tests Hitachi Room Air Conditioning Indoor and Outdoor units are manufactured according to this ISO certification system Hitachi products all carry the necessary CE declaration markings and also feature in the extensive Eurovent Listing programme Listing in the Eurovent directory helps ensure peace of mind for the installer and the end user as it certifies the important operating para...

Page 6: ... great deal of investment in research and development and testing facilities at various Hitachi factories and laboratories around the world Hitachi has continuously developed sophisticated energy saving air conditioning systems that reduce CO2 emissions and help to protect the global environment The latest Room Air Conditioning offering from Hitachi is the Framed Flat range of wall mounted units A...

Page 7: ...ng Monozone Capacity Range Kw 2 5 3 5 5 0 7 5 8 8 11 0 12 0 6 0 15 5 17 6 Multizone Nominal cooling capacities Maximum indoor combination nominal cooling capacities All DC Inverter PAM Mono Split Summit Framed Flat Capacity Range Kw 2 0 3 5 8 0 2 5 6 0 7 0 5 0 Summit YH5 Summit YH6 Monoduct Air Exchanger Bigflow Heat Pump Capacity Range Kw 2 0 3 5 2 9 5 0 6 5 Bigflow Cooling Only 7 ...

Page 8: ...ven systems This enhanced performance can be as much as 10 Features and benefits Rapid Start Up Improved Performance PAM Minimised loss of performance Hitachi s PAM Power Active Module control system mirrors the current pulse waveform to avoid distortion and therefore achieve almost 100 power factor to enhance power efficiency This cutting edge device is employed in all Hitachi Mono Multizone prod...

Page 9: ...rigerant leakage is ensured by the automatic compression system in which the tip of the slewing scroll is kept in absolute contact with the fixed scroll in addition to special processing of the scroll surface DC Twin Rotary Compressor Today all Monozone and two Multizone room air conditioning units have Hitachi s new twin rotary compressor which has even less vibration and even higher performance ...

Page 10: ...achi s room air conditioning products This ensures that the micro dust pollen particles and odours that can collect on filters can be easily removed The filters can be washed and reused up to 20 times Self Diagnosis System for Easy Servicing All air conditioning units are made with easy servicing in mind All components can be easily reached and self diagnosis is made easy Errors are easily identif...

Page 11: ...ilter and showing what does get through The Nano Titanium does not deteriorate or run out as particles and dead fungi do not accumulate on the surface so it can be used semi permanently Both the SPX CFH15 and SPX NFH1 filters are included Auto restart If the auto start mode is selected at the ON OFF switch then the unit automatically resumes operation in the mode that was in use before it was swit...

Page 12: ...Monozone Multizone ...

Page 13: ... Monozone Multizone compatible indoor unit range caters for all requirements offering wall mounted floor standing 60cm x 60cm cassettes and in the ceiling duct units designed to offer elegance and comfort to any application Comprehensive range long pipe length and easy installation You can choose and connect freely from different types of indoor and outdoor units depending on the number of rooms w...

Page 14: ...ange incorporates the R410A refrigerant Hitachi DC Scroll or DC Twin Rotary compressor all working together for high performance and ultimate efficiency New Flat Framed design DC inverter PAM control Low noise down to 20dBA on sleep mode Heating available even at 15ºC ambient temperature Auto restart and Auto changeover Washable carbon and anti bacteria air purifying filter 24hr remote control tim...

Page 15: ... 8 Air Flow Rate Heating m3 min 8 0 7 0 5 8 9 5 8 0 7 0 10 8 8 5 7 5 13 5 10 0 6 8 Refrigerant Piping Liquid Line mm in 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 9 52 3 8 12 7 1 2 Interconnection Wires pcs 3 3 3 3 Auto Restart by Previous Mode Yes Yes Yes Yes LED Self Diagnosis Yes Yes Yes Yes Air Purifying Filter Type SPX CFH11 SPX CFH11 SPX CFH11 SPX CFH11 Anti bacteri...

Page 16: ... exchanger s advanced design has a wide suction area and graduation design grill which both increase the efficiency and performance of the heat exchanger The wide suction area increases the air intake which enables the unit to adjust the room temperature quickly Clean A washable carbon and anti bacteria air purifying filter ensures that the micro dust pollen particles and odours that can collect o...

Page 17: ...0 10 8 8 5 7 5 13 5 10 0 6 8 13 5 12 5 11 3 Refrigerant Piping Liquid Line mm in 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 9 52 3 8 12 7 1 2 12 7 1 2 Interconnection wires pcs 3 3 3 3 3 Auto Restart by Previous Mode Yes Yes Yes Yes Yes LED Self Diagnosis Yes Yes Yes Yes Yes Air Purifying Filter Type SPX CFH11 SPX CFH11 SPX CFH11 SPX CFH11 SPX CFH5 Anti bacterial...

Page 18: ...rger than that of a conventional one It can easily be removed for washing or cleaning by a vacuum cleaner High performance The larger conical blade fan rotates the air flow slowly thus achieving high efficiency and low noise RAF Technical Description Floor mounted The dust collecting area is almost three times larger than that of conventional one A washable air purifying filter option can be insta...

Page 19: ...in 6 35 1 4 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 12 7 1 2 Interconnection wires pcs 3 3 3 Auto Restart by Previous Mode Yes Yes Yes LED Self Diagnosis Yes Yes Yes Air Purifying Filter Type SPX CFH5 SPX CFH5 SPX CFH5 Anti bacterial Tangential Fan Remote Control Timer Hr 24 24 24 MULTIZONE combination For capacity information please refer to Combination Table Option Not included Genera...

Page 20: ...user can select between 2 way 3 way or 4 way operation of auto swing louvers Built in drain pump This ductable unit is equipped with an internal drain pump to remove accumulated condensation water from the drain pan even while it is operating A float switch monitors the water level and automatically activates the pump as necessary One touch panel The panel can be swung open up to 90º with just one...

Page 21: ... 8 0 5 8 12 0 8 0 5 8 Refrigerant Piping Liquid Line mm in 6 35 1 4 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 12 7 1 2 Interconnection wires pcs 3 3 3 3 Auto Restart by Previous Mode Yes Yes Yes Yes LED Self Diagnosis Yes Yes Yes Yes Air Purifying Filter Type SPX CFH5 Anti bacterial Tangential Fan Remote Control Timer Hr 24 24 24 MULTIZONE combination For capacity information please refer...

Page 22: ...tandard Air in take direction can be horizontal or vertical by interchanging the bottom panel with the fan cover Auto re start by previous mode and Auto Changeover Ready to connect to PCS 6RAD adapter Built in drain pump This ductable unit is equipped with an internal drain pump to remove accumulated condensation water from the drain pan even while it is operating A float switch monitors the water...

Page 23: ...mm in 6 35 1 4 6 35 1 4 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 9 52 3 8 12 7 1 2 Interconnection wires pcs 3 3 3 3 Auto Restart by Previous Mode Yes Yes Yes Yes LED Self Diagnosis Yes Yes Yes Yes Pre Filter Yes Yes Yes Yes Air Purifying Filter Type Anti bacterial Tangential Fan Wired Remote Control Yes Yes Yes Yes Wired Remote Control Timer Hr 12 12 12 12 Wireless Remote Control Option...

Page 24: ...el 12 0 70 80QH5 15 0 75 90QH5 17 6 90 130QH5 Multizone 2 2 Rooms Monozone 1 1 Room Multizone 3 3 Rooms Multizone 4 4 Rooms Multizone 5 5 Rooms Multizone 6 6 Rooms 8 8 45 65QH5 6 0 35 40QH5 7 5 35 55QH5 5 0 20 50NH5 6 0 30 65NH5 2 5 20 25NH5 3 5 20 35NH5 11 0 60 72QH5 Nominal cooling capacity Maximum indoor combination nominal cooling capacities Chargeless 35m Chargeless 70m ...

Page 25: ... 6 0 9 5 5 0 5 0 10 0 5 0 6 0 11 0 6 0 6 0 12 0 1 8 1 8 1 8 5 4 1 8 1 8 2 5 6 1 1 8 1 8 3 5 7 1 1 8 1 8 5 0 8 6 1 8 1 8 6 0 9 6 1 8 2 5 2 5 6 8 1 8 2 5 3 5 7 8 1 8 2 5 5 0 9 3 1 8 2 5 6 0 10 3 1 8 3 5 3 5 8 8 1 8 3 5 5 0 10 3 1 8 3 5 6 0 11 3 1 8 5 0 5 0 11 8 1 8 5 0 6 0 12 8 1 8 6 0 6 0 13 8 2 5 2 5 2 5 7 5 2 5 2 5 3 5 8 5 2 5 2 5 5 0 10 0 2 5 2 5 6 0 11 0 2 5 3 5 3 5 9 5 2 5 3 5 5 0 11 0 2 5 3 5...

Page 26: ... 3 2 5 2 5 2 5 2 5 10 0 2 5 2 5 2 5 3 5 11 0 2 5 2 5 2 5 5 0 12 5 2 5 2 5 2 5 6 0 13 5 2 5 2 5 3 5 3 5 12 0 2 5 2 5 3 5 5 0 13 5 2 5 2 5 3 5 6 0 14 0 2 5 2 5 5 0 5 0 15 0 2 5 3 5 3 5 3 5 13 0 2 5 3 5 3 5 5 0 14 5 2 5 3 5 3 5 6 0 15 5 3 5 3 5 3 5 3 5 14 0 3 5 3 5 3 5 5 0 15 5 3 5 3 5 5 0 5 0 17 0 1 8 1 8 1 8 1 8 1 8 9 0 1 8 1 8 1 8 1 8 2 5 9 7 1 8 1 8 1 8 1 8 3 5 10 7 1 8 1 8 1 8 1 8 5 0 12 2 1 8 1...

Page 27: ...2 1 8 1 8 1 8 1 8 2 5 3 5 13 2 1 8 1 8 1 8 1 8 2 5 5 0 14 7 1 8 1 8 1 8 1 8 3 5 3 5 14 2 1 8 1 8 1 8 1 8 3 5 5 0 15 7 1 8 1 8 1 8 1 8 5 0 5 0 17 2 1 8 1 8 1 8 2 5 2 5 2 5 12 9 1 8 1 8 1 8 2 5 2 5 3 5 13 9 1 8 1 8 1 8 2 5 2 5 5 0 15 4 1 8 1 8 1 8 2 5 3 5 3 5 14 9 1 8 1 8 1 8 2 5 3 5 5 0 16 4 1 8 1 8 1 8 3 5 3 5 3 5 15 9 1 8 1 8 1 8 3 5 3 5 5 0 17 4 1 8 1 8 2 5 2 5 2 5 2 5 13 6 1 8 1 8 2 5 2 5 2 5 3...

Page 28: ...n Rotary x1 Indoor Fan Air Flow Rate Cooling m3 min 8 5 7 0 6 0 10 1 8 0 6 5 13 5 10 0 6 8 Air Flow Rate Heating m3 min 9 5 8 0 7 0 10 8 8 5 7 5 13 5 10 0 6 8 Condenser Fan Type DC360V DC360V DC360V Air Flow Rate Cooling Heating m3 min 27 27 27 27 36 36 Usable Outdoor Temperature Cooling 10 43 10 43 10 43 Heating 15 21 15 21 15 21 Refrigerant Piping Liquid Line mm in 6 35 1 4 6 35 1 4 6 35 1 4 Gas...

Page 29: ...8 Width mm 750 905 750 905 850 1008 850 1008 Depth mm 280 394 280 394 298 394 298 394 Weight Kg 38 43 38 43 45 50 45 50 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Compressor Type x Qty DC Twin Rotary x1 DC Twin Rotary x1 DC Twin Rotary x1 DC Twin Rot...

Page 30: ... 750 905 850 1008 Depth mm 280 394 280 394 298 394 280 394 280 394 298 394 Weight Kg 38 43 38 43 45 50 38 43 38 43 45 50 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Compressor Type ...

Page 31: ... Valve Compressor Type x Qty DC Twin Rotary x1 DC Twin Rotary x1 DC Twin Rotary x1 Indoor Fan Air Flow Rate Cooling m3 min 8 2 7 3 6 2 8 5 7 6 6 2 8 5 7 6 6 2 Air Flow Rate Heating m3 min 9 2 7 5 6 2 9 3 7 6 6 2 9 3 7 6 6 2 Condenser Fan Type DC360V DC360V DC360V Air Flow Rate Cooling Heating m3 min 27 27 27 27 36 36 Usable Outdoor Temperature Cooling 10 43 10 43 10 43 Heating 15 21 15 21 15 21 Re...

Page 32: ...DC350V Air Flow Rate Cooling Heating m3 min 27 27 36 36 36 36 Usable Outdoor Temperature Cooling 10 43 10 43 10 43 Heating 15 21 15 21 15 21 Refrigerant Piping Flair Nut Flange Connection Liquid Line mm in 6 35 1 4 x 2 6 35 1 4 x 2 6 35 1 4 x 3 Gas Line mm in 9 52 3 8 x 2 9 52 3 8 x 2 9 52 3 8 x 3 Pipe Run Max Pipe Length m 35 35 45 Max Changeless Length m 35 35 35 Additional Charge g m 20 Individ...

Page 33: ... 15 21 15 21 15 21 15 21 Refrigerant Piping Liquid Line mm in 6 35 1 4 x 4 6 35 1 4 x 4 6 35 1 4 x 5 6 35 1 4 x 6 Gas Line mm in 9 52 3 8 x 3 9 52 3 8 x 4 9 52 3 8 x 3 9 52 3 8 x 6 12 7 1 2 x1 12 7 1 2 x 2 Pipe Run Indoor Indoor 1 2 3 4 5 6 Max Pipe Length m 60 35 35 75 45 45 Max Changeless Length m 30 35 35 30 35 35 Additional Charge g m 20 15 20 20 Individual Pipe Length m 25 25 25 25 25 Max Pip...

Page 34: ...2 50 6 0 2300 10 60 2 61 0 9 5 6 155 2000 0 9 7 5 155 2530 RAK 65NH5 6 0 2300 10 10 2 63 7 05 2400 10 50 2 94 0 9 6 5 155 2500 0 9 9 0 115 2700 RAC 25NH5 RAC 35NH5 RAC 50NH5 RAC 65NH5 Cooling Mode Heating Mode Combination of Indoor Unit Total Capacity Total Total Total EER Capacity Total Total Total COP kW kW kW Input W Current A kW Input W Current A 1 8 1 8 1 80 1 8 560 2 5 3 21 2 50 2 5 690 3 0 ...

Page 35: ...0 5 2 3 03 2 50 2 50 5 00 1460 6 4 3 42 1 50 4 00 200 1300 1 50 5 20 200 1550 1 8 2 5 4 3 1 80 2 40 4 20 1310 5 8 3 21 2 40 3 80 6 20 1820 8 0 3 41 1 50 4 60 200 1450 1 50 6 30 200 1920 1 8 3 5 5 3 1 70 3 30 5 00 1650 7 2 3 03 2 30 4 50 6 80 1995 8 8 3 41 1 50 5 60 200 1820 1 50 7 20 200 2100 1 8 5 0 6 8 1 40 4 00 5 40 1795 7 9 3 01 2 00 5 00 7 00 2050 9 0 3 41 1 50 5 90 200 1980 1 50 7 20 200 210...

Page 36: ...0 6 3 26 2 00 6 60 380 2380 2 20 9 50 390 3120 2 5 5 0 7 5 2 4 4 7 7 1 2530 11 1 2 81 2 9 5 7 8 6 2470 10 8 3 48 2 00 7 50 380 2980 2 20 9 50 390 3120 2 5 6 0 8 5 2 1 5 0 7 1 2450 10 8 2 90 2 55 6 05 8 6 2450 10 8 3 51 2 00 7 50 380 2980 2 20 9 50 390 3120 3 5 3 5 7 0 3 5 3 5 7 0 2630 11 6 2 66 4 3 4 3 8 6 2670 11 7 3 22 2 00 7 40 380 2940 2 20 9 50 390 3120 3 5 5 0 8 5 2 9 4 2 7 1 2530 11 1 2 81 ...

Page 37: ... 2210 9 7 3 21 2 86 2 86 2 86 8 6 2280 10 0 3 77 2 20 8 00 420 2960 2 40 9 50 430 2600 1 8 1 8 1 8 1 8 7 2 1 77 1 77 1 77 1 77 7 1 2140 9 4 3 32 2 15 2 15 2 15 2 15 8 6 2200 9 7 3 91 2 40 7 90 450 2870 2 60 9 50 460 2520 1 8 1 8 1 8 2 5 7 9 1 6 1 6 1 6 2 3 7 1 2140 9 4 3 32 2 0 2 0 2 0 2 6 8 6 2200 9 7 3 91 2 40 8 30 450 3020 2 60 9 50 460 2520 1 8 1 8 1 8 3 5 8 9 1 45 1 45 1 45 2 75 7 1 2140 9 4 ...

Page 38: ...80 4 80 9 6 3300 14 5 2 91 1 50 8 20 640 3040 1 50 10 60 600 3630 1 8 1 8 3 6 1 80 1 80 3 6 1120 4 9 3 21 2 25 2 25 4 5 1280 5 6 3 52 1 50 4 00 640 1230 1 50 5 20 600 1480 1 8 2 5 4 3 1 70 2 30 4 0 1280 5 6 3 13 2 20 2 60 4 8 1360 6 0 3 53 1 50 4 50 640 1400 1 50 5 50 600 1600 1 8 3 5 5 3 1 60 3 40 5 0 1660 7 3 3 01 2 00 3 80 5 8 1580 6 9 3 67 1 50 5 50 640 1830 1 50 6 40 600 1740 1 8 5 0 6 8 1 50...

Page 39: ... 2 5 7 9 1 80 1 80 1 80 2 50 7 9 2580 11 3 3 06 2 40 2 40 2 40 3 80 11 0 2630 11 6 4 18 3 00 9 00 650 3100 3 00 12 40 620 3630 1 8 1 8 1 8 3 5 8 9 1 60 1 60 1 60 3 20 8 0 2650 11 6 3 02 2 30 2 30 2 30 4 10 11 0 2630 11 6 4 18 3 00 9 20 650 3200 3 00 12 40 620 3630 1 8 1 8 1 8 5 0 10 4 1 40 1 40 1 40 3 80 8 0 2650 11 6 3 02 2 0 2 00 2 00 5 00 11 0 2630 11 6 4 18 3 00 9 20 650 3200 3 00 12 40 620 36...

Page 40: ... 2160 9 5 3 56 B 2 40 6 60 450 2400 2 7 9 2 480 2590 2 5 5 0 7 5 2 5 5 0 7 50 2880 12 6 2 60 D 3 16 6 04 9 20 2720 11 9 3 38 C 2 40 8 30 450 3470 2 7 10 5 480 3110 2 5 6 0 8 5 2 4 5 6 8 00 2750 12 1 2 91 C 3 08 6 62 9 70 2940 12 9 3 30 C 2 40 8 80 450 3300 2 7 11 0 480 3320 3 5 3 5 7 0 3 5 3 5 7 00 2490 10 9 2 81 C 4 3 4 3 8 60 2460 10 8 3 50 B 2 40 7 70 450 2990 2 70 10 0 480 2860 3 5 5 0 8 5 3 3...

Page 41: ...25 4 50 9 00 2780 12 2 3 24 A 2 66 2 66 5 08 10 40 2990 13 1 3 48 B 2 70 9 90 510 3360 2 9 11 6 520 3330 2 5 2 5 6 0 11 0 2 05 2 05 4 90 9 00 2780 12 2 3 24 A 2 51 2 51 5 38 10 40 2990 13 1 3 48 B 2 70 9 90 510 3360 2 9 11 6 520 3330 2 5 3 5 3 5 9 5 2 36 3 32 3 32 9 00 2750 12 1 3 27 A 2 94 3 73 3 73 10 40 2890 12 7 3 60 B 2 70 9 90 510 3330 2 9 11 6 520 3220 2 5 3 5 5 0 11 0 2 05 2 85 4 10 9 00 2...

Page 42: ...1 3 56 A 1 57 1 57 2 69 4 57 10 40 2700 11 9 3 85 A 2 90 9 90 550 3260 3 0 11 6 540 3010 1 8 1 8 5 0 5 0 13 6 1 20 1 20 3 30 3 30 9 00 2510 11 0 3 59 A 1 44 1 44 3 76 3 76 10 40 2700 11 9 3 85 A 2 90 9 90 550 3230 3 0 11 6 540 3010 1 8 1 8 5 0 6 0 14 6 1 10 1 10 3 10 3 70 9 00 2510 11 0 3 59 A 1 46 1 46 3 80 4 28 11 00 2630 11 6 4 18 A 2 90 9 90 550 3230 3 0 12 1 540 2890 1 8 2 5 2 5 2 5 9 3 1 80 ...

Page 43: ...5 14 0 2 25 2 25 2 25 2 25 9 00 2530 11 1 3 56 A 2 75 2 75 2 75 2 75 11 00 2630 11 6 4 18 A 2 90 9 90 550 3260 3 0 12 1 540 2890 3 5 3 5 3 5 5 0 15 5 2 03 2 03 2 03 2 91 9 00 2530 11 1 3 56 A 2 44 2 44 2 44 3 68 11 00 2630 11 6 4 18 A 2 90 9 90 550 3260 3 0 12 1 540 2890 1 8 1 8 1 8 1 8 1 8 9 0 1 8 1 8 1 8 1 8 1 8 9 00 2360 10 4 3 81 A 2 2 2 2 2 2 2 2 2 2 11 00 2460 10 8 4 47 A 3 20 9 90 600 3040 ...

Page 44: ... 3 2 3 11 00 2460 10 8 4 47 A 3 20 9 90 600 3040 3 40 12 10 610 2710 1 8 2 5 2 5 2 5 3 5 12 8 1 26 1 76 1 76 1 76 2 46 9 00 2360 10 4 3 81 A 1 6 2 2 2 2 2 2 2 8 11 00 2460 10 8 4 47 A 3 20 9 90 600 3040 3 40 12 10 610 2710 1 8 2 5 2 5 2 5 5 0 14 3 1 14 1 57 1 57 1 57 3 15 9 00 2360 10 4 3 81 A 1 45 1 95 1 95 1 95 3 7 11 00 2460 10 8 4 47 A 3 20 9 90 600 3040 3 40 12 10 610 2710 1 8 2 5 2 5 2 5 6 0...

Page 45: ...1 50 5 90 200 2200 1 50 7 20 200 2110 1 8 1 8 1 8 5 4 1 80 1 80 1 80 5 40 1780 7 8 3 03 B 2 33 2 33 2 33 7 00 1850 8 2 3 78 A 1 50 6 00 200 2200 1 50 7 20 200 2110 1 8 1 8 2 5 6 1 1 80 1 80 2 50 6 10 2020 8 9 3 02 B 2 00 2 00 3 20 7 20 1900 8 4 3 79 A 1 50 6 40 200 2200 1 50 7 20 200 2110 1 8 1 8 3 5 7 1 1 60 1 60 3 10 6 30 2095 9 2 3 01 B 1 85 1 85 3 50 7 20 1900 8 4 3 79 A 1 50 6 60 200 2200 1 5...

Page 46: ...0 5 00 2 70 4 50 14 20 4160 18 3 3 41 B 1 50 11 80 200 3960 1 50 14 40 200 4210 1 8 3 5 3 5 3 5 12 3 1 70 3 30 2 70 2 70 10 40 3445 15 1 3 02 B 2 30 4 50 3 60 3 60 14 00 4105 18 0 3 41 B 1 50 11 50 200 3800 1 50 14 40 200 4210 1 8 5 0 3 5 3 5 13 8 1 40 4 00 2 70 2 70 10 80 3590 15 8 3 01 B 2 00 5 00 3 60 3 60 14 20 4160 18 3 3 41 B 1 50 11 80 200 3960 1 50 14 40 200 4210 1 8 5 0 3 5 5 0 15 3 1 40 ...

Page 47: ...0 1 8 1 8 3 5 13 9 1 60 1 60 3 10 11 70 200 4180 17 1 3 01 B 1 85 1 85 3 50 14 20 200 4210 17 3 3 59 B 1 50 12 50 1 50 14 40 1 8 5 0 1 40 4 00 3890 2 00 5 00 3950 1 8 1 8 5 0 15 4 1 30 1 30 3 70 11 70 200 4180 17 1 3 01 B 1 60 1 60 4 00 14 20 200 4210 17 3 3 59 B 1 50 12 50 1 50 14 40 2 5 2 5 2 50 2 50 3670 3 40 3 40 3915 1 8 1 8 2 5 11 1 1 80 1 80 2 50 11 10 200 4020 16 1 3 02 B 2 00 2 00 3 20 14...

Page 48: ...11 70 200 4180 17 1 3 01 B 2 23 2 23 2 74 14 40 200 4220 17 6 3 59 B 1 50 12 50 1 50 14 40 3 5 3 5 2 70 2 70 3890 3 60 3 60 4010 2 5 2 5 3 5 15 5 1 85 1 85 2 60 11 70 200 4180 17 1 3 01 B 2 23 2 23 2 74 14 40 200 4220 17 6 3 59 B 1 50 12 50 1 50 14 40 3 5 5 0 2 20 3 20 4090 3 05 4 15 4010 2 5 2 5 3 5 17 0 1 85 1 85 2 60 11 70 200 4400 18 0 2 86 B 2 23 2 23 2 74 14 40 200 4220 17 6 3 59 B 1 50 12 5...

Page 49: ...5 3 5 17 4 1 30 2 50 2 50 12 60 200 4400 18 4 3 01 B 1 40 2 90 2 90 14 40 200 4220 16 7 3 79 A 1 50 13 20 1 50 14 40 1 8 2 5 2 5 1 70 2 30 2 30 4190 1 80 2 70 2 70 3800 1 8 2 5 2 5 13 6 1 70 2 30 2 30 12 60 200 4400 18 4 3 01 B 1 80 2 70 2 70 14 40 200 4220 16 7 3 79 A 1 50 13 20 1 50 14 40 1 8 2 5 2 5 1 70 2 30 2 30 4190 1 80 2 70 2 70 3800 1 8 2 5 3 5 14 6 1 50 2 00 2 80 12 60 200 4400 18 4 3 01...

Page 50: ...8 4 3 01 B 2 23 2 23 2 74 14 40 200 4220 16 7 3 79 A 1 50 13 20 1 50 14 40 Six Units At least four indoor units should be connected One unit indicated are only for one unit operation when four indoor units or more are connected Two units indicated are only for two units operation when four indoor units or more are connected Three units indicated are only for three units operation when four indoor ...

Page 51: ...ission system and can be controlled by CS Net Applicable to RAD 25 35 50 NH7 and RAD 50 60 70 DH7 only PM RAD 18 NH7 Wired Remote Control Hard wired remote control with built in 12 hour timer Applicable to In the Ceiling RAD 25 35 50 NH7 and Monoduct ranges RAD 50 60 70 DH7 SPX RCK1 Wireless Remote Control Kit Wireless remote control which can be used in place of the standard wired remote control ...

Page 52: ...orporates the R410A refrigerant Hitachi DC Scroll or DC Twin Rotary compressor all working together for high performance and ultimate efficiency New Flat Framed design DC inverter PAM control Highest COP up to 4 31 AA in cooling 4 30 AA in heating Low noise down to 20dBA on sleep mode Cooling available under 10ºC ambient temperature Heating available even at 15ºC ambient temperature Auto restart a...

Page 53: ...Depth mm 288 377 288 377 298 394 Weight Kg 35 38 35 38 45 50 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Compressor Type x Qty DC Scroll x1 DC Scroll x1 DC Twin Rotary x1 Indoor Fan Type DC 35V DC 35V DC 35V Air Flow Rate Cooling m3 min 8 5 7 0 6 0 10 1 8 0 6 5 13 5 10 0 6 8 Air Flow R...

Page 54: ...es the R410a refrigerant Hitachi DC Scroll or DC Twin Rotary compressor all working together for high performance and ultimate efficiency DC inverter PAM control Highest COP up to 4 31 A in cooling 4 30 A in heating Low noise down to 20dBA on sleep mode Cooling available under 10 C ambient temperature Heating available under 15ºC ambient temperature Auto restart by previous mode and Auto changeove...

Page 55: ...7 288 377 288 377 298 394 298 394 298 394 315 417 Weight Kg 35 38 35 38 35 38 45 50 45 50 52 57 75 87 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A R410A R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve ...

Page 56: ...n mono split SUMMIT range incorporates R410A refrigerant and the Hitachi DC Rotary compressor all working together for high performance and ultimate efficiency DC inverter PAM control Highest COP both in cooling and heating both models are class A Low noise down to 20dBA on sleep mode Heating available even at 15ºC ambient temperature Auto restart and Auto changeover Washable carbon and anti bacte...

Page 57: ... 871 Depth mm 258 352 258 352 288 377 Weight Kg 27 29 27 29 35 38 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Compressor Type x Qty DC Rotary x1 DC Rotary x1 DC Rotary x1 Indoor Fan Type DC 35V DC 35V DC 35V Air Flow Rate Cooling m3 min 7 3 6 7 5 8 8 5 7 0 6 0 10 0 8 0 6 5 Air Flow Rat...

Page 58: ...loped wired remote controller with built in 12 hour timer Optional remote controller also available using SPX RCK1 remote control kit Adjustable static pressure Drain pump as standard Air in take pre filter as standard Air in take direction can be horizontal or vertical by interchanging the bottom panel with the fan cover Cooling available under 10 C ambient temperature Heating available under 15 ...

Page 59: ...1008 Depth mm 298 394 298 394 298 394 Weight Kg 55 60 55 60 55 60 Cabinet Colour Munsell Code Beige 5Y 7 2 Beige 5Y 7 2 Beige 5Y 7 2 Refrigerant R410A R410A R410A Flow Control Expansion Valve Expansion Valve Expansion Valve Compressor Type x Qty DC Rotary x 1 DC Rotary x 1 DC Rotary x 1 Indoor Fan Type DC 320V DC 320V DC 320V Air Flow Rate Cooling m3 min 15 13 11 15 13 11 16 13 11 Air Flow Rate He...

Page 60: ...ompact design reliability and high efficiency this range is suited to a wide variation of applications Energy label A class COP Low noise down to 23dBA on sleep mode Heating available under 10ºC ambient temperature Auto restart by previous mode Washable carbon and anti bacteria air purifying filter 24hr remote control timer R410A refrigerant RAS RAC Technical Description Bigflow ...

Page 61: ...Refrigerant R410A R410A R410A R410A R410A Flow Control Capillary Capillary Capillary Capillary Capillary Compressor Type x Qty AC Rotary x 1 AC Rotary x 1 AC Rotary x 1 AC Rotary x 1 AC Rotary x 1 Indoor Fan Type DC35V DC 35V DC 35V DC 35V DC 35V Air Flow Rate Cooling m3 min 8 0 6 5 5 0 9 0 7 5 6 0 10 0 8 5 7 0 13 5 12 5 11 3 13 5 12 5 11 3 Air Flow Rate Heating m3 min 8 0 6 5 5 0 9 0 7 5 6 0 10 0...

Page 62: ...g units the R410a refrigerant is used and the Air Exchanger range utilises the Hitachi twin rotary compressor Two way Air Exchange Self clean function DC Inverter PAM control Highest COP of this class Ultra quiet Cooling available under 10 C ambient temperature Heating available under 15ºC ambient temperature Auto restart by previous mode and Auto changeover Nano Titanium filter and washable carbo...

Page 63: ... new handset If the system is set for automatic exchange a gas sensor situated in the unit will detect and check the condition of the air regularly and activate the automatic operation when required Self clean function The new Air Exchanger range has another key benefit as it has a self clean function built in which makes sure the indoor unit is always clean and hence the air quality from the unit...

Page 64: ...ilable There is no additional connection of the air pipe between the indoor and outdoor units DC Inverter PAM control As the pioneer of all DC Inverter PAM driven Room Air Conditioners our units boast the significant advantage of all DC Inverter PAM driven compressors and fans Enhanced inverter performance and system performance are achieved by the addition of a DC drive These advantages include r...

Page 65: ... 7 8 5 8 4 7 Air Flow Rate Heating m3 min 9 5 7 8 5 6 3 8 10 8 8 2 6 5 5 0 Condenser Fan Type DC350V DC350V Air Flow Rate Cooling Heating m3 min 31 27 32 28 Usable Outdoor Temperature Cooling _ 10 43 10 43 Heating _ 15 21 15 21 Refrigerant Piping Flair Nut Flange Connection Liquid Line mm in 6 35 1 4 6 35 1 4 Gas Line mm in 9 52 3 8 9 52 3 8 Pipe Run Max Pipe Length m 20 20 Chargeless m 20 20 Indi...

Page 66: ......

Page 67: ......

Page 68: ...t notice in order that HITACHI may bring the latest innovations to their customers Omitting typing errors Hitachi Europe Ltd Whitebrook Park Lower Cookham Road Maidenhead Berkshire SL6 8YA United Kingdom email aircon enquiries hitachi eu com www hitachiaircon com HELGB RAC 003 ...

Reviews: