19
Model
RAF-25NH5
RAF-35NH5
RAF-50NH5
Power Supply
DC 35V
DC 35V
DC 35V
Sound Pressure Level (Over
a
ll Sc
a
le)
Cooling
dBA
35/31/26/23
40/35/28/24
44/37/28/24
Heating
dBA
35/31/26/25
41/35/31/26
44/39/34/31
Outer Dimensions (Net/(C
a
rton)
Height
mm
600(656)
600(656)
600(656)
Width
mm
750(797)
750(797)
750(797)
Depth
mm
215(278)
215(278)
215(278)
Weight
Kg
15(17)
15(17)
15(17)
Refriger
a
nt
R410A
R410A
R410A
Flow Control
–
–
–
Indoor F
a
n
Air Flow Rate Cooling
m
3
/min
7.2/5.0/4.5
9.5/5.5/5.0
10.3/8.5/6.0
Air Flow Rate Heating
m
3
/min
8.7/7.5/6.2
10.8/8.5/7.2
12.3/10.0/7.5
Refriger
a
nt Piping
Liquid Line
mm (in)
6.35 (1/4)
6.35 (1/4)
6.35(1/4)
Gas Line
mm (in)
9.52 (3/8)
9.52 (3/8)
12.7(1/2)
Interconnection wires
pcs
3
3
3
Auto Rest
a
rt by Previous Mode
Yes
Yes
Yes
LED Self Di
a
gnosis
Yes
Yes
Yes
Air Purifying Filter Type
(SPX-CFH5)*
(SPX-CFH5)*
(SPX-CFH5)*
Anti-b
a
cteri
a
l T
a
ngenti
a
l F
a
n
–
–
–
Remote Control Timer
Hr
24
24
24
MULTIZONE combination. For capacity information please refer to Combination Table *Option. Not included
Gener
a
l D
a
t
a
NOTES:
Cooling Operation Conditions
Heating Operation Conditions
Indoor Air Inlet Temperature:
27 ˚C DB
Indoor Air Inlet Temperature:
20 ˚C DB
19 ˚C WB
Outdoor Air Inlet Temperature: 35 ˚C DB
Outdoor Air Inlet Temperature: 7 ˚C DB
6 ˚C WB
Piping Length:
7.5 meters
Sound Pressure Level Measurement Distance:
Piping Lift:
0 meters
1m from discharge grille
Half of unit height from floor level