Microlok II
®
Serial-to-Ethernet Converter (SEC)
Copyright 2019 SM6800O Rev. 1, March 2019
3-17
After the SEC has been rebooted, it will use the new settings, including the IP address you
specified in the edited niacfg.ini file.
YELLOW LED (LINK STATUS)
GREEN LED
(NETWORK ACTIVITY/DIAGNOSTIC)
Figure 3-19 - Digi Module Front View Showing Yellow and Green LEDs
3.9
18B
SEC Configuration Options
23B
3.9.1
24B
Changing Network Settings
You may need to change network settings in addition to the IP address, such as the netmask
and gateway. These settings are in the [GENERAL] section niacfg.ini file, as shown in
. This is the same section as the IP address. To access these settings see Section
the procedure.
NOTE
Changes to the configuration file should be made only with
information supplied by the networking or IT personnel.
[GENERAL]
IP=192.168.1.10
NETMASK=255.255.0.0
GATEWAY=192.168.1.1
DHCP is not supported.
Figure 3-20 - GENERAL Section of the niacfg.ini File
3.10
19B
Uploading new SEC Firmware
The design of the SEC includes a Digi-Connect ME (Micro Embedded) device server. The
server, a file system, and user data are maintained on a flash EPROM that is part of the device
server. From time to time, upgrades to the firmware, the manufacturer's software that
implements the device server and file system, are made available by the manufacturer (Digi
International). These upgrades typically include minor bug fixes and enhancements of features.
Summary of Contents for Microlok II
Page 2: ......
Page 12: ...Microlok II Serial to Ethernet Converter SEC Copyright 2019 SM6800O Rev 1 March 2019 1 4 ...
Page 38: ......
Page 40: ...Microlok II Serial to Ethernet Converter SEC Copyright 2019 SM6800O Rev 1 March 2019 4 2 ...
Page 50: ...Microlok II Serial to Ethernet Converter SEC Copyright 2019 SM6800O Rev 1 March 2019 6 2 ...
Page 52: ...Microlok II Serial to Ethernet Converter SEC Copyright 2019 SM6800O Rev 1 March 2019 7 2 ...