17
CP-X2520 ( M2-25ED ) / CP-X3020 ( M2-30ED )
6-2 Before Replacing The LCD Prism assembly
1. Preparation
Please prepare cleaning tools and materials as follows. And prepare relatively clean room not to work in
additional dust, while removing operation.
(1) Swab for cleaning : P#: NX32451, "Cotton stick BB-014"
(2) Air duster (Dust blower, spray can)
(3) Vacuum cleaner
2. Disassembling and setting up.
(1) Turn off the projector, and unplug the power cord.
(2) Remove the lamp cover, the UPPER CASE and the PWB assembly MAIN with the PWB assembly
INPUT. According to the disassembling diagram of chapter 8.
6-3 Cleaning the dust off the panels and optical filters
WARNING
Wear sunglasses to protect your eyes when you maintain the projector with its lamp on.
Do not disassemble the unit
because replacement of separate
parts is not possible.
CAUTION
Make sure not to let a screwdriver touch LCD panels when you replace a LCD prism assembly with a new one.
You should not replace separately the parts of the LCD prism
assembly. In case of a failure in any parts of LCD/PRISM
assembly, replace the whole LCD/PRISM assembly.
CAUTION
Do not let the contacts of panel flexible cables touch any other parts.
Do not put stress on the terminals of the PWB assembly MAIN and the PWB assembly INPUT.
Summary of Contents for (M2-30ED
Page 51: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...
Page 52: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 63: ...CP X2520 M2 25ED CP X3020 M2 30ED 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 1 ...
Page 64: ...CP X2520 M2 25ED CP X3020 M2 30ED 1 2 3 4 5 6 1 2 3 4 5 6 A B C D E F G POWER UNIT BALLAST 2 ...
Page 80: ...CP X2520 CP X3020 SM0339 ...