L200 Inverter Specifications
Model-specific tables for 200V and 400V class inverters
The following tables are specific to L200 inverters for the 200V and 400V class model
groups. Note that
“General Specifications” on page 1–10
apply to both voltage class
groups. Footnotes for all specifications tables follow the table below.
Item
200V Class Specifications
L200 inverters,
200V models
EU version
002NFEF
004NFEF
005NFEF
007NFEF
011NFEF
USA version
002NFU
004NFU
—
007NFU
—
Applicable motor size *2
kW
0.2
0.4
0.55
0.75
1.1
HP
1/4
1/2
3/4
1
1.5
Rated capacity
(kVA)
230V
0.5
1.0
1.1
1.5
1.9
240V
0.5
1.0
1.2
1.6
2.0
Rated input voltage
1-phase: 200 to 240V ±10%, 50/60 Hz ±5%,
3-phase: 200 to 240V ±10%, 50/60 Hz ±5%,
(037LFU, 055LFU, and 075LFU 3-phase only)
Integrated EMC
filter
EU version
Single phase filter, Category C3 *5
USA version
—
Rated input
current (A)
1-phase
3.1
5.8
6.7
9.0
11.2
3-phase
1.8
3.4
3.9
5.2
6.5
Rated output voltage *3
3-phase: 200 to 240V (proportional to input voltage)
Rated output current (A)
1.4
2.6
3.0
4.0
5.0
Starting torque *7
100% at 6Hz
Braking
Dynamic
braking, approx.
% torque (short
time stop from
50 / 60 Hz) *8
100%:
≤
50Hz
50%:
≤
60Hz
Capacitive feedback type, dynamic braking unit and braking
resistor optional, individually installed
DC braking
Variable operating frequency, time, and braking force
Weight
EU version
(-NFEF
kg
0.8
0.95
0.95
1.4
1.4
lb
1.75
2.09
2.09
3.09
3.09
US version
(-NFU)
kg
0.7
0.85
—
1.8
—
lb
1.54
1.87
—
3.97
—