background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
When a lens-connector-free automatic iris lens is used, the 
optional lens plug is installed in the lens cable as follows. 
Please refer the manual for signal and color combination of 
camera cable. 
 

 

DC

Direct current

control voltage input type lens 

 
 
 

 

 

 

Video signal input type lens 

 
 
 
 
 
Install the head of lens cable to plug and then insert the plug in 
the lens connector [LENS] of camera. 

 
 

1) Dimension A) of lens installation part should be according to

the figure below. When the lens with dimention more than the
following size is installed, the internal damage of camera may
occur. 

2) Please do not install a lens which is heavier than the camera

body. In case of using such lens, please fix the lens to the
installation stand. 

Lens selection 

Caution 

Use of heavy lens may damage the camera because of 
unbalance. 

C mount lens

less than 4.1mm 

CS mount lens

less than 4.1mm 

Lens 

Flange surface of lens 

Lens connectors 

Lens 

 
 

Flange back adjustment is needed after installation of lens or in
cases where focus cannot be obtained by normal lens focus
operation and focus is lost at the wide angle settings of a zoom
lens. 
In such cases, open the lens iris (refer to page 9) and adjust as
follows. 

1) Fixed focus lens 

Set the lens focus ring to infinity and pickup a camera subject 
at least 20 meters distant. Loosen the lens mount setscrews 
(2 screws) and turn the lens and lens mount ring to adjust the 
focus. After adjusting, tighten the lens mount setscrews. 

 

2) Varifocal and Zoom lens 

 1) Set the lens to maximum telephoto and pickup a camera 

subject at least 20 meters distant. Loosen the lens mount 
setscrews (2 screws) and turn the focus ring to adjust the 
focus while using care not to turn the lens and lens mount 
ring. 

2) Set the lens to maximum wide angle and pickup the same 

camera subject. While using care not to turn the lens focus 
ring, turn the lens and lens mount ring to adjust the focus. 
Repeat these steps until focus is obtained at both telephoto 
and wide angle settings. After adjusting, tighten the lens 
mount setscrews. 

 

Flange back adjustment

 

  The flange back adjustment can adjust C~CS mount range. 

  The angle of view is adjusted by turning the lens zoom ring. 

 

 

Damping coil

    - 

Damping coil   

+ 

Driving coil 

- 

Driving coil 

+ 

+

12V

 

Video input

GND

Note

 

KP-HD20A camera has strucuture that user can change lenses.
Therefore dust may adhere to the CCD or the optical filter unit 
depending on environmental conditions where lens are attached 
to this camera. If you use this camera under the bright outdoor 
conditions, dust may be seen depending on the aperture of lens 
In such cases we recommend that you use AES & LENS mode.
 

Summary of Contents for KP-HD20A

Page 1: ... manual Thank you for procuring this fine Hitachi Kokusai Electric color camera Before using the camera please read this operation manual carefully and keep this manual on file for ready reference in the future Hitachi Kokusai Electric Inc E400359115 ...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...gle because it is full HD Low delay HD video signal and long distance transmission at the time of multiunit connection High sensitivity 1 3 type high sensitivity MOS sensor has made 0 2lux high sensitivity High functioning Full HD and double shutter WDR function 1080 30fps double shutter WDS function Coaxial superposition A simple system configuration is possible by one cable connection Introducti...

Page 6: ... and adjustment values are confirmed and changed with these 3 switches Refer to page 6 to 10 Setting menu operations HD SDI output connector SDI Refer to page 3 Video output connection Video output connector VIDEO Refer to page 3 Video output connection Camera attachment screw hole C mount adapter optional accessories LENS mount ring Attachment of C mount adapter Attachment of tripod adapter Lens ...

Page 7: ...V 5C 2V and 3C 2V are not guaranteed to support high frequency signal transmission of HD SDI mode Connections DVI D moronit RGB monitor NTSC PAL monitor DVI D cable RGB cable Coaxial cable Coaxial cable Refer to cable length standard AC100 230V MU HD101 back HD SDeye color camera KP HD20A Supported formats XGA 60p SXGA 60p Supported formats 1080 59 94i 1080 50i 1080 29 97p 1080 25p XGA 60p SXGA 60...

Page 8: ...et the lens focus ring to infinity and pickup a camera subject at least 20 meters distant Loosen the lens mount setscrews 2 screws and turn the lens and lens mount ring to adjust the focus After adjusting tighten the lens mount setscrews 2 Varifocal and Zoom lens 1 Set the lens to maximum telephoto and pickup a camera subject at least 20 meters distant Loosen the lens mount setscrews 2 screws and ...

Page 9: ...ing can occur at certain iris positions In such case please refer to page 9 Lens open setting and set the lens to full open At this time AES is operated Auto Electric Shutter AES AES is a function to automatically adjust the electronic shutter speed according to the amount of incident light and keeps the image level constant ...

Page 10: ...E OFF WDR MODE AUTO WDR BLEND 128 WDR SHUTTER 1 2000 WDR LEVEL 0 SYSTEM MENU SDI OUTPUT HD SDI TV FORMAT 1080p 59 94 VBS ASPECT 16 9 SUB MENU CHROMA 0 DETAIL 0 PEDESTAL 0 GAMMA ON KNEE ON KNEE S P MASKING PREST HUE SAT INITIALIZE PUSH R TV FORMAT 1080i 59 94Hz 1080i 50 Hz 1080p 29 97Hz 1080p 25 Hz MASKING HUE SAT R 150 R 128 Y 128 Y 128 G 172 G 128 C 150 C 128 B 120 B 128 M 160 M 128 INITIALIZE PU...

Page 11: ...u on the monitor screen 2 Use UP and Down buttons to move the cursor to MAIN MENU push the Right and Left button to change the scene file FILE1 FILE2 FILE3 FILE4 FILE5 FILE1 Factory setting is FILE1 Main menu LIGHT CONT MENU Light control menu Exposure control mode Video level adjustment Automatic level conrol gate setting WDR function setting WDR brend ratio setting WDR short exposure shutter set...

Page 12: ...etting R gain Manual setting B gain Auto level conrol gate setting White balance setting menu SUB MENU 1 CHROMA Chroma level setting 128 to 0 to 50 Choroma level is fixed to the value of 128 and cannot be adjusted at time of B W MODE 2 DETAIL The optimum detail levelseting 128 to 0 to 127 3 PEDESTAL Set black level 28 to 0 to100 4 GAMMA Gamma correction setting ON Gamma ON HIGH Gamma ON High OFF G...

Page 13: ...left 7 Character blink of a character setting part moves to the one character left 8 DEL The blinking character eliminate 9 INS A space is inserted in the position of the blinking character 10 RET A cursor is moved to DATA SET TITLE 9 1 LENS TYPE DC type or VIDEO type VIDEO B W MODE AUTO does not operate at the time of AGC OFF and SENSUP OFF manual DC To which control of the lens of DC input contr...

Page 14: ...ten seconds Caution Please do not turn off the power by any means during the change of output mode NTSC PAL mode change HD SDI HD VLC mode change Button operation at a camera start up 1 Starting in HD SDI mode A power supply is started pushing an Up button 2 Starting in HD VLC mode A power supply is started pushing a Right button Exclusive multiunit MU HD101 is required for HD VLC mode An optional...

Page 15: ...ount Adaptor optional accessory use 10 Power consumption DC12V or Coaxial superposition from MU HD101 5 8W 11 Operating temperature 10 to 45 C 12 External dimensions 44 W x44 H x59 D mm 13 Mass Approx 130g 14 Accessory optional accessory Lens Lens plug Tripod adapter Power plug Remote plug Multiunit MU HD101 15 AGC OFF Auto Max Gain 48dB Manual 0dB to 48dB 1dB step setting 16 Electronic shutter OF...

Reviews: