23
produced ( a normal picture will not be obtained ). Use a sync signal that is free of noise.
Trigger specifications: 5 Volts p-p +0.5 / 1.0 Volt p-p
High period 8
µ
s or more
15. Non-interlaced operation
When non-interlaced external sync drive signals (HD/VD) are connected from an external unit, the mode
is automatically switched to non-interlaced scanning mode. When the following external sync drive
signals are connected, the camera operates in the non-interlaced mode.
Input signals
HD and VD signals
HD EIA : f(H)=15.734kHz
±
1%
CCIR: f(H)=15.625kHz
±
1%
VD EIA : f(V)=f(H) . (262
±
)(Hz)
CCIR: f(V)=f(H) . (312
±
)(Hz)
Input level
2 to 6Vp-p, negative
Input impedance
1k ohms
Waveforms of external drive signal (non-interlaced scanning).
The waveforms are the same as those of 2:1 interlaced external sync drive signals.