As can be seen, there are several functions within this menu. Simply use the ‘arrow’ keys to scroll
through the menu with the cursor. Once the desired setting has the cursor on it, use the ‘enter’ key to
go to that particular settings submenu, or change its current setting. Each setting is described below.
Read Mode setting
There are 2 modes that the handheld can be put into:
vehicle mode
and
single stem mode.
In
vehicle mode,
the handheld will read up to 4 stems, associate them to a particular vehicle (PVI, VIN,
etc.), and to a particular wheel (Left Front, Right Front, etc.). In this mode, the handheld communicates
all the stem serial numbers and pressures associated with a vehicle through its serial communication
port. It also communicates the vehicle identifier (PVI, VIN, etc.) This mode is typically used for a TPM
Data Extraction System.
In
single stem mode
then only a single stem is read and displayed. This is intended for use in a tire and
wheel assembly operation.
Units
This setting selects the units that the pressure will be set to. MPa or PSI are available.
Vehicle ID
This setting allows the operator to set the acronym that will be used for the vehicle identification. VIN &
PVI are available as selections. This selection also changes the serial output of the handheld.